Wasserfilter Germany A2O Pure Especificaciones técnicas

A2O Pure
Use and
installation
manual

2
Pure
water
nothing
else

3
A2O Pure
Use and installation manual
4
5
9
10
11
12
21
24
Control via app
About A2O Pure
Dimensions and weight
List ofincluded components
Installation scheme
How to install
Operating instructions
Replacement of filters
Maintenance
For the most updated installation manuals in
more languages, go to Aquaporin.com/installation or
contact the store where you bought your device.
27

4
Control
via app
Connect with your purifier
Connect your A2O purifier with your
smartphone to manage and track your water
usage in real time.
Receive updates
Receive recommendations to make using
your A2O purifier simpler and get reminders
when it’s time to change filters.
Track usage
Get an overview of your water usage,
monitor filter lifetime, see next maintenance,
and track the effectiveness of your water
purification.
Access information
Access manuals and useful information
about water.

5
About
A2O Pure
The A2O Pure is a direct flow water purifier
with Aquaporin Inside® technology. The
device can be used wherever traditional
reverse osmosis (RO) devices or other types
of water devices reach their limits.
The Aquaporin Inside® Drinking Water
Membrane (DWRO®) uses unique “made by
nature” proprietary membrane technology
to remove PFAS, pesticides, heavy metals,
microplastics, bacteria, viruses, hormones,
nitrates, limescale, and other harmful
substances.
Input water requirements
Feedwater temperature (min. / max.) 5–25 °C
Inlet pressure (min. / max.) 1–6 bar
Feedwater quality Municipal tap water
Technical details
Model name A2O Pure
Product category Under-the-sink
Filters
Number Name Material Lifetime
1. Pre filter PP cotton + Activated carbon 12 months or 4,500 L
2. Post filter Activated carbon 12 months or 4,500 L
3. DWRO® Aquaporin Inside® membrane 24 months or 7,000 L

6
Technical data
Flow rate of filtered water12.1 L/min
Water recovery rate265% (2:1)
Membrane capacity 126 L/h
Salt rejection2> 90%
Electrical connection 220–240V AC
Power consumption (operation) 95 W
Power plug standard EU
Noise level 53 ±1 dB
Wi-Fi connection + app Yes
Leak detector Yes
Membrane flushing (auto-cleaning) Yes
Feedwater, pure water and wastewater connection ½ or ⅜3, ¼, ¼ inch
Dimensions (W×D×H) 315 × 203 × 427 mm
Weight 8.57 kg
Regulatory information EUFCM and
1The flow rate is tested at 25 °C; lower water temperatures will reduce the flow rate.
2The device is influenced by feedwater conditions such as pressure, temperature, TDS levels, and hardness.
The better these incoming conditions, the better the performance. Depending on the local water quality and
use environment, the lifetime of the filters, flow rate, recovery rate and salt rejection will vary.
3Local variations apply, contact your reseller for more information.

7
General information
This manual contains important instructions
for safe and efficient use of the A2O Pure. It
is part of the device and must be constantly
available at the place of operation.
Installation or maintenance done on this
device by an untrained service person
can cause major damage to equipment or
property damage.
Description of symbols listed
This manual uses the following symbols.
The warnings/instructions are introduced by
signal words to underline risks. The warnings/
instructions must be complied with. The
operator must act carefully to avoid accidents
and property damage.
Danger: Electric current or voltage!
Always consult a qualified electrician
when this symbol is shown.
Attention: Dangerous spot! Shows
instructions or prohibitions to avoid
personal injury or extensive damage
to property.
Observe: Underlines useful
recommendations and information
for an efficient operation, free of
interruptions.
Warranty and disclaimer
Observe: The information and
instructions contained in the
manual have been compiled based
on current standards, regulations,
and technology, as well as our
experiences, and observations.
The warranty is void in any of the following
cases:
-Failure to follow the provisions and
information in this manual
-Improper use
-Improper or faulty installation
-Improper start-up, operation, or
maintenance
-Use of non-approved components or
non-original parts
-Failure to perform the required service
and replacement tasks
-Technical modifications: damage,
faults and stoppages resulting from
unauthorized alterations
Responsibilities of the operator
-This manual must be easily accessible
and kept in the immediate vicinity of the
device.
-The device must be operated in a
technically faultless and operationally
safe condition only.
-The provisions in the manual are to be
followed at all times.

8
Operating and safety notes
Despite all possible precautionary measures,
some residual risk remains with any product,
especially if it is used improperly. Warranty
claims are void unless the provisions in this
manual are observed and followed.
Proper use
The device is suitable for filtration of drinking
water quality at up to max. 25 °C and an inlet
pressure of max. 6 bar.
Observe: The feedwater must not
exceed the limit values given in the
technical data sheet – see page 5.
The device must only be used for its intended
purpose as designed and as described here
in this manual. Any other use is considered
“improper”.
Warning! The device must be fed
cold drinking water only.
Permissible operation method
Observe: To protect the drinking
water, observe the country-specific
guidelines for drinking water
installations when performing any
work on the device.
-The device must be disconnected prior
to performing any maintenance work on
the drinking water supply. Rinse the water
pipe sufficiently before reconnecting the
device.
Observe: Improper installation of the
device may cause damage to it.
-Observe any country-specific installation
regulations (such as DIN 1988, EN 1717),
general hygienic practices and technical
data for protecting the drinking water.
-Unauthorized modifications to the device
and technical alterations are not permitted.
-Avoid mechanical damage to the device.
Otherwise, the warranty is void.
-Install a stop valve upstream of the device.
-All materials in contact with filtered water
must be corrosion resistant.
-The device must not be installed in the
vicinity of heat sources or open flames.
-The device must not come into contact
with chemicals, solvents, or vapors.
-The installation site must be free of frost
and protected from direct sunlight.
-The device must not be operated with
feedwater that is microbially contaminated
or is of unknown origin or quality.
-A water softener is strongly recommended
for water > 15 °dH. Using the device with
water hardness higher than 15 °dH will
reduce the lifetime of the device and its
filters.
-Avoid leaving the device in storage
for a long time to reduce the risk of
contamination.
Impermissible operating methods
Attention: Danger through improper
use! Claims for damages resulting
from improper use are void.
Danger: Always disconnect the
device from the power supply by
removing the plug or fuse when
performing any maintenance or
electrical work.

9
Dimensions
and weight
Net weight: 8.57 kg
427 mm
315 mm
315 mm
203 mm
203 mm

10
Push-in
fitting
1×
Device
incl. filters
1×
PE pipe
1/4″
1×
PE pipe
3/8″
1×
List of included components
T-piece with ball
valve, ½ or ⅜″
Local size variations
may occur - please
check with your local
dealer.
1×
DRAIN CLAMP KIT
Drain clamps
1×
Screw + nut
2×
Gasket
1×
Pressure reducer
incl. check valve
1×
Tools
required for
installation
2 x adjustable spanners
(or 1 x 19 mm spanner
and 1 x 23 mm spanner)
Flat and
Phillips
screwdriver
Pincer Electrical drill
(7 mm and
12 mm drill bits)
Faucet
1×
Spacer
1×
Upper
(white)
gasket
1×
Lower
(black)
gasket
1×
Plastic nut
1×
2C
76
2B
5
2A
4
13
8A
8B 8D8C 8E 9 10
Retaining
ring 1/4″
(green)
5×
Retaining
ring 3/8″
(blue)
4×
Tabla de contenidos