Waferlock L701 Manual de usuario

L701
User Manual
Smart Lock
www.waferlock.com
ISO9001 CERTIFIED

1
WAFERLOCK CORPORATION
CONTENT
Your Warranty
CE Marking
Your Warranty covers all manufacturers' defects in workmanship and material. It does not cover any unit that is damaged beyond normal
usage, by improper installations, by contacts to chemicals, or any other acts or omissions unsanctioned within the user manual.
All components are covered for one (1) year after the date of purchase or installation from supplier.
The user is required to provide dated proof of purchase. Waferlock or its authorized distributor will determine if there is a warrantable
condition associated with material and/or manufacturing workmanship.
If the lock conforms to the warranty conditions, the lock will be repaired free of charge. The shipping freights would be at owner's expense.
The warranty does not include any further obligation whatsoever, including but not limited to the installation of the replacement unit to the
customer's lock.
All other warranties, express or implied, are disclaimed. All collateral agreements, which purport to modify this limited warranty, are of no
effect.
This device has been tested to and conforms to the regulatory requirements of the European Union and has attained CE Marking. The CE
Mark is a conformity marking consisting of the letters “CE”. The CE Mark applies to products regulated by certain European health, safety
and environmental protection legislation. The CE Mark is obligatory for products it applies to: the manufacturer afxes the marking in order
to be allowed to sell his product in the European market.
This product conforms to the essential requirements of the R&TTE directive 1999/5/EC in order to attain CE Marking.
The CE Marking is not a quality mark. Foremost, it refers to the safety rather than to the quality of a product. Secondly, CE Marking is
mandatory for the product it applies to, whereas most quality markings are voluntary.
P02Main Feature
Technical Specication
STANDALONE MODE PROGRAMMING INSTRUCTION
P03
Program New User Cards / Tags
Program New Pin Code
Delete Individual User (Cards / Tags / Pin Codes)
Delete All User (Cards / Tags / Pin Codes)
Set Up The Lock As Toggle Mode / Set Up The Lock As Standard Mode
Set Up The Lock As Dual Mode / Set Up The Lock As Single Mode
Combination Of Lock Modes / Reset The Lock Master Code
Open Door With User Card / Open Door With Pin Code
P05
P06
P07
P08
P09
P10
P11
P12
P13
P14
Change Master Pin Code
P04Lock set up with App
Low Power Warning / Emergency External Power Supply
Serial No. / Name List

2
WAFERLOCK CORPORATION
• 3 in 1: Opening the door by pin code, user card / tag and mobile phone
• UID with Mifare Classic / DESFire and ISO 14443A card
• Low battery with acoustic warning sound
• Number of users:
Standalone mode: Pin Code + Key Card / Tag, up to 250
Pairing with App: App Access + Pin Code + Key Card / Tag, up to 2,000
• 4~6 digits user code
• 4~6 digits master code
• Support 9V external power supply
• Adjustable opening mode:
• Escutcheon size: 290mm (H) x 40mm (W) x 20.5mm (D)
• Battery life: Up to 1.5 years (10 opening a day), at service 20°C
• Battery: CR2 x 1 pcs
• Suitable for door thickness 35-73mm as standard
Main Feature
Technical Specication
④
③
②
①
②
①
Standard + Single Mode ( Once unlocking, then automatically locking after 6 seconds. )
Standard + Dual Mode ( Once unlocking, then automatically locking after 6
seconds + Dual access authentication. )
Toggle + Single Mode ( Toggling automatic to manual locking mode. )
Toggle + Dual Mode
( Toggling automatic to manual locking mode + Dual access authentication.)

3
WAFERLOCK CORPORATION
• Master Pin Code can be programmed from 4 to 6 digits.
• Master Pin Code can be used to open door if no user code/card/tag is programmed, once a new
user is programmed, Master Pin Code will not be able to use to open the door.
• Master Pin Code can be used to open door if all user cards/tags are deleted.
Step 1
Step 2
Step 3
Step 4
Press any button to activate the keypad, then press 0 # to set up the Master Pin Code.
Enter Default Master Pin Code 123456, then press #.
Enter NEW Master Pin Code, then press #.
Re-enter the new 4~6 digits again, then press #.
Change Master Pin Code (Default is 123456)
Default Master Pin Code is 123456.
Correct Master Pin Code: 1 beep followed by green
light ashing 1 time.
Incorrect Master Pin Code: 2 beeps followed by red
light ashing 2 times, then standby.
If enter less than 4 digits or over 6 digits, 2 beeps
followed by red light ashing 2 times.
If code already exists, 2 beeps followed by red light
ashing 2 times, then standby.
If new Master Pin Code is programmed, 1 beep
followed by green light ashing 1 time.
If the code does not match rst code you entered,
2 beeps followed by red light ashing 2 times, then
standby.
If the code matches, 1 beep followed by green light
ashing 1 time.
Note

4
WAFERLOCK CORPORATION
• The WAFERKEY App works on iPhone with iOS 13.6 or later, or devices with Android 8.0 or later.
• Be sure to accept any available rmware update.
• Please refer to the instruction in WAFERKEY App for more information.
• Once the lock turns to App Mode, ALL the existing user access settings (Key Card, Passcode ...)
will be deleted.
Note
Lock Setup with App
Follow below steps to get your lock setup with WAFERKEY App.
You can also use the mobile App to set up your lock step-by-step and access installation videos.
Step 2
Open the App, simply use a Third Party Login
or register a WAFERKEY account.
Step 3
Turn on Bluetooth on your smartphone, stay near
the lock and follow the instruction in the App.
Step 4
Pair the lock in the App and start to use it.
Step 1
Download the App by searching “WAFERKEY”
in the App Store (iOS) or on Google Play (Android).
DON’T WANT TO USE THE APP?
Please go to page P05-12 for manual programming instructions for Standalone Mode.
Questions about your new lock?
Let us help you!

5
WAFERLOCK CORPORATION
STANDALONE MODE PROGRAMMING INSTRUCTION
• When programming a new user card or new pin code, it will create a 3-digit (001, 002, 003...)
“Serial Number” inside lock's memory. Please write down this serial number.
• When performing deleting function, this serial number will be needed. Please use Serial No. /
Name List page in last pages as a note to copy down the serial number for the user.
Note
Program New Users Card / Tags
Step 1
Step 2
Step 3
Press any button to activate the keypad, then press 1 # to program new users.
Enter Master Pin Code, then press #.
Tap new user card to the reader.
Default Master Pin Code is 123456.
Correct Master Pin Code: 1 beep followed by green
light ashing 1 time.
Incorrect Master Pin Code: 2 beeps followed by red
light ashing 2 times, then standby.
If the lock has been programmed
with 250 users already, 2 beeps
followed by red light ashing 2
times, then standby.
If user card/tag is programmed: 1 beep followed by
green light ashing 1 time, then standby.
If a user card/tag card already exists, 2 beeps followed
by red light ashing 2 times, then standby.
User
Standalone Mode programming functions
(Master Pin Code) are NOT available after
the lock is paired with mobile App!
If you would like to use Standalone Mode, please
unpair the lock via WAFERKEY App.
Please remember to change
Master Pin Code (Default is 123456),
referring to the instruction on P03.
WARNING

6
WAFERLOCK CORPORATION
• When programming a new user card or new pin code, it will create a 3-digit (001, 002, 003...)
“Serial Number” inside lock's memory. Please write down this serial number.
• When performing deleting function, this serial number will be needed. Please use Serial No. /
Name List page in last pages as a note to copy down the number for the user.
Step 1
Step 2
Step 3
Step 4
Press any button to activate the keypad, then press 1 #.
Enter Master Pin Code , then press #.
Enter 4~6 digits, then press # (0~9 only, it does not include Pin Code # sign).
Re-enter the new 4~6 digits again, then press #.
Program New Pin Code
Default Master Pin Code is 123456.
Correct Master Pin Code: 1 beep followed by green
light ashing 1 time.
Incorrect Master Pin Code: 2 beeps followed by red
light ashing 2 times, then standby.
If enter less than 4 digits or over 6 digits, 2 beeps
followed by red light ashing 2 times, then standby.
If code already exists, 2 beeps followed by red light
ashing 2 times, then standby.
If code is programmed, 1 beep followed by green light
ashing 1 time.
If the code does not match rst code you entered, 2
beeps followed by red light ashing 2 times, then standby.
If the code matches, 1 beep followed by green light
ashing 1 time.
Note
If the lock has been programmed
with 250 users already, 2 beeps
followed by red light ashing 2
times, then standby.

Delete Individual User (Cards / Tags / Pin Codes)
• When performing deleting function, other user's serial number will not be changed.
• When the existing user is deleted, user's serial number will be left blank, the next programmed
user will replace this blank spot. “i.e.: Deleting serial no.004, and then programming a new user,
this new user will be serial no. 004”.
• If there are more than one serial no. deleted, the next programmed user will replace that spot
ascending sequence; i.e.: no.004 and no.100 are deleted, the next programmed user will replace
the no.004 spot, and the following programmed user will replace no.100.
Note
Step 1
Step 2
Step 3
Press any button to activate the keypad, then press 2 #.
Enter current Master Pin Code, then press #.
Enter the existing serial number (3 digits, 001~250), then press #.
Correct Master Pin Code: 1 beep followed by green
light ashing 1 time.
Incorrect Master Pin Code: 2 beeps followed by red
light ashing 2 times, then standby.
If enter less than 3 digits or over 3 digits, 2 beeps
followed by red light ashing 2 times, then standby.
If the serial number does not exist, it will be successful
delete individual user, 1 beep followed by green light
ashing 1 time.
If correct, user will be deleted, 1 beep followed by
green light ashing 1 time.
7
WAFERLOCK CORPORATION

8
WAFERLOCK CORPORATION
Step 1
Step 2
Step 3
Press any button to activate the keypad, then press 3 #.
Enter current Master Pin Code, then press #.
Re-enter Master Pin Code, then press #.
Delete All User (Cards / Tags / Pin Codes) Reset the lock to default
Correct Master Pin Code: 1 beep followed by green
light ashing 1 time.
Incorrect Master Pin Code: 2 beeps followed by red
light ashing 2 times, then standby.
Correct Master Pin Code: 1 beep followed by green
light ashing 1 time.
Incorrect Master Pin Code: 2 beeps followed by red
light ashing 2 times, then standby.
• When all User Card and Pin Code are deleted, the lock will be reset to default setting.
Master Pin Code will be reset to 123456.
• If the lock was in Dual Mode or Toggle Mode, it will also be set back to Standard + Single Mode.
Note
Otros manuales para L701
4
Tabla de contenidos
Idiomas:
Otros manuales de Cerrar de Waferlock

Waferlock
Waferlock L701 Manual de usuario

Waferlock
Waferlock C-700 Series Manual de usuario

Waferlock
Waferlock L310 Manual de usuario

Waferlock
Waferlock C760 Manual de usuario

Waferlock
Waferlock L700 Manual de usuario

Waferlock
Waferlock WEL-7103 Manual de usuario

Waferlock
Waferlock L701 Manual de usuario

Waferlock
Waferlock L701 Manual de usuario

Waferlock
Waferlock C-700 Series Manual de usuario

Waferlock
Waferlock C210 Manual de usuario