VYKING FORCE VF2200IG Manual de usuario

2.5kVA Generator VF2200IG
INSTRUCTION
MANUAL
To prevent serious injury, read and understand all warnings and
instructions before use. Keep these instructions safe for future
use.

Contents
Hazard signal word denitions 5
Before starting 6
General warnings & disclaimer 7
Recommended oil type 13
Component identication 14
Control panel identication 15
Generator set up 16
Power load planning & management 21
Initial oil ll 22
Adding/checking engine uids & fuel 24
Starting the inverter 27
Stopping the inverter 28
During an emergency 29
Using efciency mode 29
Connecting loads 30
DC overload cut out 32
Carbon build up 32
Storage 33
Maintenance & repair 35
Maintenance schedule 49
Maintenance log 51
Troubleshooting 52
Wiring diagram 54
Generator diagram 55
Engine diagram 56
Warranty information 57

3
2.5kVA Inverter Generator VF2200IG
About your generator
Thanks for your purchase of this Vyking Force Generator. This generator is suitable
for home, farm, camping, sports and leisure. With built-in Pure Sine Wave technology
(THD≤3%), it’s also ideal for powering tools, domestic appliances and sensitive
electronic devices.
Please read and understand the content of this manual for safety guidelines, start-up,
shutdown, operation, adjustment and maintenance instructions before using this product.
Take all possible precautions to protect your own safety and that of the people in the
immediate vicinity. Save this manual for future reference.

4
Specications
Max power 2200 W
Rated power 2000 W
Voltage 220 - 240V~ 50Hz
240 V outlets 1 x 15 A IP44
Amps 8.3 A
Power factor 1
Pure sine wave THD < 3%
Alternator Permanent magnet
Phase 1
Engine type Vyking Force 4 stroke air cooled OHV
Engine horse power 2.8 HP
Engine displacement 98cc
Spark plug type E6RTC (NGK part no: BPR6HS)
Engine oil type SAE 30
Engine oil capacity 350 ml
Engine start Recoil
Fuel tank size 3.7 L
Fuel type Regular 91 RON
Run time (100%) 2.7 hours
Run time (50%) 4.5 hours
Low oil shutdown Yes
EPA compliant Yes
Circuit breaker N/A Self protected
USB Inputs Type C & QC 3.0
12V DC Power Yes
Eco Mode Yes
Product dimensions (LxWxH) 500mm x 285mm x 455mm
Net weight 21 kg
Gross weight 26.5 kg
Rated noise level at 7M 71 dB
Vyking Force is constantly improving its products. All information in this manual is based
on the latest product information available at the time of printing. The specications
outlined herein are subject to change without prior notice or obligation. The purchaser
and/or user shall assume liability for any modication and/or alterations of this equipment
from original design and manufacture.

5
2.5kVA Inverter Generator VF2200IG
Unpacking and delivery inspection
You should inspect the generator immediately after you receive delivery. If you have
missing or damaged parts, contact your place of purchase. Do not operate this product if
there’s any issue with the parts.
Part QTY
Funnel 1
Spark Plug Wrench 1
12V DC Cable 1
Hazard signal word denitions
This manual uses the following symbols to help differentiate between different kinds of
information. The safety symbol is used with a key word to alert you to potential hazards
in operating and owning power equipment. Follow all safety messages to avoid or
reduce the risk of serious injury or death.
!Indicates an imminently hazardous situation
which, if not avoided, will result in death or
serious injury. Obey all safety messages that
follow this symbol to avoid possible injury or
death.
!DANGER Indicates an imminently hazardous situation
which, if not avoided, will result in death or
serious injury.
!WARNING Indicates a potentially hazardous situation
which, if not avoided, could result in death or
serious injury.
!CAUTION Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderate injury.
CAUTION Used without the safety alert symbol indicates
a potentially hazardous situation which, if not
avoided, may result in property damage.

6
Before starting
The generator is shipped without oil. You must add an adequate amount of engine oil before
rst use. The engine will be damaged beyond repair if it’s started without oil. For oil type,
please see “Recommended Oil Type” section of this manual on page 13. Fresh regular RON
(Research Octane Number) 91 fuel must be used in this unit. DO NOT use premium or
Ethanol based fuels.
Read and understand all safety warnings and instructions in this manual before proceeding
with use of the product or recommended maintenance tasks. Keep this instruction manual
for future reference.
Safety symbols on product & packaging
Comply with the instructions provided by the safety signs and symbols tted to the
pressure washer and in this manual. The pressure washer and manual only feature the
symbols relevant to the model purchased. Check that the symbols and signs afxed
to the unit are always present and legible; otherwise, t replacements in the original
positions.
For protection against injury, wear earmuffs and safety goggles.
Wear safety gloves during use to protect hands.
Wear non-slip footwear that will protect your feet and improve your
footing on slippery surfaces.
The motor is hot, do not touch
Sound power level is 71dB
Australian Regulatory Compliance Mark (RCM)
71

7
2.5kVA Inverter Generator VF2200IG
Safety signs
Comply with the instructions provided by the safety signs and symbols tted to the
generator and in this manual. The generator and manual only feature the symbols
relevant to the model purchased. Check that the symbols and signs afxed to the unit
are always present and legible.
General warnings and disclaimer
READ and UNDERSTAND this manual completely before using the engine! Failure to
properly set up, operate, and maintain this engine could result in serious injury or death
from carbon monoxide poisoning, electric shock, re/explosion, or burns. In particular, be
aware of the following hazards:
CO Poisoning
Engines give off carbon monoxide, an odourless, colourless poisonous gas that can kill
you. You CANNOT smell it, see it, or taste it.
ONLY run engine OUTDOORS and AWAY from building air intakes. NEVER run engine
inside any enclosed or semi-enclosed spaces, including homes, basements, garages,
sheds, boxes, RVs, boats or pick-up truck beds. These spaces can trap poisonous
gases, EVEN if you run a fan or open windows.
Electric Shock / Electrocution
High voltage electricity from the generator can kill. DO NOT operate in wet locations. Be
sure the generator is properly grounded. Use only outdoor-rated grounded extension
cords of proper size. NEVER plug the generator directly into a wall outlet. ANY
connection to a building’s electrical system MUST ISOLATE THE GENERATOR FROM
UTILITY POWER via a transfer switch installed by a licensed electrician. Otherwise,
back feed from the generator into the power grid could kill utility workers.
Heat
Unintentional spark can result in re or electric shock.
Fire / Explosion
DO NOT overload engine (per rated capacity) and OPERATE ONLY in an area with
adequate cooling ventilation so engine does not overheat. Exhaust can be extremely
hot. Keep mufer at least 2 metres from all combustible objects.
All fuels are ammable. Never fuel a running or hot engine. Never pump fuel directly into
engine at petrol station – use an approved container to transfer fuel. Ensure there are
no fuel leaks, and keep sources of sparks and ames away. Wait for the engine to cool
before fueling. ALWAYS keep a re extinguisher rated “ABC” nearby.

8
STOP!
CHOOSE THE RIGHT GENERATOR FOR YOUR NEEDS. See the Power Load
Planning & Management section on page 21 to determine your power load requirements
and then compare to the generator’s rated capacity.
INSPECT COMPONENTS: Closely inspect to make sure no components are missing or
damaged. ARRANGE FOR PROFESSIONAL INSTALLATION of a transfer switch if you
will be connecting the generator to your building’s electrical system. See the “Generator
Set-Up” section for more information about this requirement.
General safety rules for operation
!WARNING Read all safety warnings, instructions,
illustrations and specications provided with
this generator. Failure to follow all instructions
listed below may result in electric shock, re
and/or serious injury.
Save all warnings and instructions for future reference.
This equipment is to be only used for the purpose for which it is designed and intended.
Seek assistance if required when moving or lifting the generator.
Work area safety
• Intended for outdoor use only. DO not operate in conned spaces or indoors, carbon
monoxide released in the exhaust can kill.
• Do not operate in explosive atmospheres, such as in the presence of ammable
liquids, gases or dust.
• Keep children and bystanders away while operating a generator. Distractions can
cause you to lose control.
• Keep your work area clean and well lit. Cluttered benches and dark areas invite
accidents.
• This generator is not weatherproof. Exposure to rain, damp conditions or extreme /
temperature can cause damage or serious injury.
Personal safety
• Stay alert, watch what you are doing and use common sense when operating a
generator. Do not use a generator while you are tired or under the inuence of
drugs, alcohol or medication. A moment of inattention may result in serious personal
injury.

9
2.5kVA Inverter Generator VF2200IG
• Use personal protective equipment. Always wear eye protection. Wear approved
safety impact eye goggles. Dust mask, non-skid safety shoes, hard hat, or hearing
protection must be used for appropriate conditions.
• Do not overreach. Keep proper footing and balance at all times. This enables
better control of the generator in unexpected situations.
• Dress properly. Do not wear loose clothing, gloves, neckties or jewellery. Keep
your hair and clothing away from moving parts. Loose clothes, jewellery or long
hair can be caught in moving parts.
• Do not let familiarity gained from frequent use of generator allow you to become
complacent and ignore safety principles. A careless action can cause severe injury
within a fraction of a second.
• For your own safety, do not operate your generator until it is completely assembled and
installed according to the instructions and until you have read and understood all of the
instructions.
Generator safety rules
• Do not force the generator. Use the correct generator for your application. The
correct generator will do the job better and safer at the rate for which it was designed.
• Do not use the generator if the engine switch does not turn it on and off. Any
generator that cannot be controlled with the switch is dangerous and must be repaired.
• Know proper use / how to stop. Be thoroughly familiar with proper use of the
equipment and all engine controls, output receptacles, and connections. Know how to
stop the engine quickly (see “Stopping the Generator”).
• Instruct operators. The engine owner must instruct all operators in safe engine set-up
and operation. Only trained adults should set up and operate the engine – Do not let
children operate.
• Intended use. Carefully read about and understand the intended use of this engine.
Do not use for other purposes, as unforeseen hazards or equipment damage may
result.
• Under the inuence. Never operate, or let anyone else operate the engine while
under the inuence of alcohol, drugs, or medication.
• Safety equipment / controls. Do not operate the engine unless all safety covers,
guards, and barriers are in place and in good working order, and all controls are
properly adjusted for safe operation.
• Damaged. Do not operate the generator with damaged, missing, or broken parts.
• Modications. Do not modify the generator in any way. Modications can create
serious safety hazards and will also void the warranty.

10
• Generator speed. Never attempt to modify the generator speed setting. The generator
speed is preset for safe and optimal performance of the generator. If speed needs
adjusting, it must be done by factory authorised personnel.
• External fuel sources. Never attempt to connect external fuel sources in order to
increase generator run time. Larger tank at pressure or higher elevation will cause to
leak from carburettor during operation. Fire or explosion could result.
• Adjusting / repairing. Always turn off generator and remove spark plug(s) or spark
plug wire(s) before working on the generator to prevent accidental starting. Always
discharge the capacitor before working on the generator head to prevent electrical
shock.
• Carbon monoxide poisoning. The running generator gives off carbon monoxide,
a poisonous gas that can kill you. You CANNOT smell it, see it, or taste it. Follow
all instructions for site selection and positioning the generator, and avoid inhaling
the exhaust. If you start to feel sick, dizzy, or weak while using the generator, shut off
the generator and get to fresh air RIGHT AWAY. See a doctor. You may have carbon
monoxide poisoning.
• Malfunction during operation. Immediately turn off the generator if any of the
following conditions arise during operation:
Excessive change in generator speed, slow or fast
Sparking or arcs from generator
Loss of electrical output
Receptacle damage
Generator misre
Excessive vibration
Flame or smoke
Abnormal noise
• Other exhaust dangers. This product contains or emits chemical known to the
Commonwealth of Australia to cause cancer, birth defects or other reproductive harm.
Avoid inhalation of exhaust.
• Wet conditions. Do not operate the engine or handle any electrical equipment while
standing in water, while barefoot, while hands are wet or while in the rain or snow.
Electric shock may result.
• Avoid contact. Avoid contact with bare wires, terminals, connections, etc. while the
unit is running.
Tabla de contenidos