Safety Precautions
These instructions are intended to ensure that the user can use the product correctly to
avoid danger or property loss.
WARNINGS:
Installation or usage of this product that is not in accordance with the intended
use as defined by the supplier and as described in the instructional materials
can result in damage, injury, or death.
Make sure this product is not accessible by children and those for whom
operation of the system is not intended.
All installation and operation should conform to your local electrical safety
codes. The power shall conform to the requirement in the SELV (Safety Extra
Low Voltage) and the Limited power source is rated 12V DC in the IEC60950-1.
If the device is permanently connected to an electrical power supply, then the
connection should include an easily-accessible disconnection device, such as a
circuit breaker. Do not connect the two power supplying sources to the device
at the same time; it may result in device damage!
Do not ever attempt to repair your device by yourself, as doing so could result
in damage, injury or death – always contact your installer / supplier agent for
service.
CAUTIONS:
Make sure the power supply voltage is correct before using the camera.
Do not drop the camera or subject it to physical shock.
Do not touch sensor modules with fingers. If cleaning is necessary, use a clean
cloth with a bit of ethanol and wipe it gently.
Do not aim the camera lens at the strong light such as sun or incandescent
lamp. The strong light can cause fatal damage to the camera.
The sensor may be burned out by a laser beam, so when any laser equipment is
being used, make sure that the surface of the sensor not be exposed to the laser
beam.
Do not place the camera in extremely hot, cold temperatures (the operating
temperature should be between -10°C ~ +50°C).
To avoid heat accumulation, good ventilation is required for a proper operating
environment.
Keep the camera away from water and any liquid.
While shipping, the camera should be packed in its original packing.
NOTE: We assume no liability or responsibility for all the fires or electrical shock
caused by improper handling or installation. We are not liable for any problems caused
by unauthorized modification or attempted repair.

3
Introduction
RISCO Group presents VUpoint, a revolutionary live video verification solution
which seamlessly integrates IP Cameras within RISCO’s professional security
systems. Powered by the RISCO Cloud (RISCO Application Server), VUpoint
provides an unprecedented level of security and live video monitoring
capabilities to monitoring stations and end-users alike. The RISCO cube indoor
IP Camera is an important part of this solution and
is easily controlled through
RISCO’s intuitive Web and Smartphone applications.
Features
Plug & Play installation
1.3 Megapixel
Color HD
Day/Night
IR LED Length 10m
Two-way audio
Components and Accessories
RISCO IP camera and
mounting bracket:
Installation guide

4
IP Camera Components and Dimensions

5
Figure 1 IP Camera Components
Label Description
1 Network port (Wireless connection mode is available as well)
2 Reset/WPS (Wi-Fi Protected Setup) button
3 Digital input/output
4 Power port
5 Built-in speaker
6 Micro SD card slot
7 Indicator light
8 Built-in MIC
9 IR LED
10 PIR (Sense IR ray, trigger alarm)

6
Note:
For reset (used to return the camera settings to factory default mode), long
press for 15 seconds and then the light turns off
For WPS (Wi-Fi Protected Setup), one quick press.
Indication Status
Red light normally on Booting
Green light slow
flashing
Booting completed, await WiFi config, enter smart config status;
Green light quick
flashing
WiFi smart config in progress, including WPS (WiFi Protected
Setup), management frame and etc.
Green light normally
on
Wifi connection succeeded, operate normally.
Red and green lights
flash alternately
Device upgrade
Red light slow flashing Network connection failure or disconnection after network
connection success.
Red light quick
flashing
Device malfunction, fail to boot up; alarm or SD card
malfunction

7
Figure 2 IP Camera Dimensions
IP Camera Installation
After reading the installation instructions and before installing your IP camera,
prepare a plan for mounting the IP camera at your protected site. Correct
placement of your IP camera is crucial for optimal security-monitoring
performance. First, determine which areas need to be protected and then map
out the most optimal areas for installing your IP camera.

8
IMPORTANT! – Please make a record of the MAC
address located on the box or on the back cover of
the IP camera before installation. You may need it
during the network connection stage.
Mounting the IP Camera
The IP camera support two mounting options; ceiling and wall mount (see Figure
3, below).
Figure 3 Wall / Ceiling Mount
IMPORTANT- Please make sure the installation surface can support at least 3
times the weight of the camera and the bracket.
Step Description
1 Place the installation positioning template on the installation surface such as
ceiling or wall.
2 Make holes in the installation surface according to the installation positioning
template.
3 Insert the expansion bolts from the accessories bag into the holes you just made.
4 Position the IP camera base over the holes
MAC address