visionLINE VL-45B Manual de usuario

ELECTRIC FLAT PANEL FIREPLACE HEATER
Model# : VL-36B
VL-60B
VL-45B VL-50B VL-55B
VL-65B VL-72B VL-100B
OWNER’S MANUAL
36"/45"/50"/55"/60"/65"/72"/100"
Wall Mounted / Built-in Electric Fireplace
AC 220-240V 50Hz 1400-1600W
WARNING
Read and understand this entire owner’s manual, including all safety
information, before plugging in or using this product. Failure to do so could
result in fire, electric shock, or serious personal injury.
CAUTION
Keep this owner’s manual for future reference. If you sell or give this
product away, make sure this manual accompanies this product.

2
IMPORTANT SAFETY INFORMATION!
WARNING
Read all instructions before using this heater!
This heater is hot when in use. To avoid burns, DO NOT let bare skin touch hot surfaces. If
provided, use handles when moving this heater. Keep combustible materials, such as
furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9m) from the front of
the heater, and keep them away from the sides and rear.
Extreme caution is necessary when any heater is used by or near children or invalids and
whenever the heater is left operating and unattended.
DO NOT operate any heater with a damaged cord or plug or after the heater malfunctions,
has been dropped or damaged in any manner. Discard heater, or return to authorized service
facility for examination and/or repair.
DO NOT run power cord under carpeting. DO NOT cover power cord with throw rugs, runners,
or similar coverings. DO NOT route power cord under furniture or appliances. Arrange power
cord away from traffic area, and where it will not be tripped over.
Connect to properly grounded outlets ONLY.
DO NOT insert or allow foreign objects to enter any ventilation or exhaust opening, as
this may cause electric shock or fire, or damage the heater.
To prevent a possible fire, DO NOT block air intakes or exhaust in any manner. Doing so could
cause a fire.DO NOT use on soft surfaces, like a bed, where openings may become blocked.
A heater has hot and arcing or sparking parts inside.DO NOT use it in areas where
gasoline, paint, or flammable liquids are used or stored.
Use this heater only as described in this manual. Any other use not recommended by
the manufacturer may cause fire, electric shock, or injury to persons.
ALWAYS plug heaters directly into a wall outlet/receptacle. NEVER use with an
extension cord or relocatable power tap (outlet/power strip).
DO NOT place the heater near a bed because objects such as pillows or blankets can fall off
the bed and be ignited by the heater.
NEVER use this heater in bathrooms, laundry rooms, or any other location where the heater
could fall into a bathtub or pool,become damp, or come in contact with water.
AVOID FIRE! Regularly inspect all air vents to make sure they are free from dust, lint, or other
blockage. Unplug the unit and clean with a vacuum ONLY.DO NOT rinse or get wet.
ALWAYS mount to wall bracket before use. DO NOT set on the floor, or other surface, to use.
NEVER use a wall mount bracket from another manufacturer.
This product is not intended to be a primary heat source. It is for supplemental heat only.
INDOOR use only! NEVER use this heater outdoors! Doing so may result in electric shock!
Risk of electric shock!DO NOT OPEN! No user-serviceable parts inside!

3
ALWAYS turn this heater off before unplugging it from the outlet.
ALWAYS disconnect this unit from the power supply before performing any assembly or
cleaning, or before relocating the electric fireplace.
NEVER leave this heater unattended. ALWAYS unplug this heater when not in use.
ALWAYS store this heater in a dry location. NEVER use the fireplace if it has become wet.
NEVER plug this heater into an outlet that is old,cracked, or has any loose wires or
connections. Plugging this heater into a faulty outlet could result in electric arcing within the
outlet that could cause the outlet to overheat or catch fire.
ALWAYS check your heater cord and plug connections with each use!
i) MAKE SURE the plug fits tight in the outlet! Faulty wall outlet connections or loose plugs
can cause the outlet to overheat.
ii) Heaters draw more current than small appliances. Overheating may occur even if it has
not occurred with the use of other appliances.
iii) During use check frequently to see if the plug outlet or face plate is HOT!
iv) If the outlet or face plate is HOT,discontinue use immediately and have a qualified
electrician inspect and/or replace the faulty outlets.
Preparation
This product includes a GLASS panel! Always use extreme caution when handling
glass. Failure to do so could result in personal injury or property damage.
Remove all parts and hardware from the carton and place them on a clean, soft, dry surface. Parts
and assembly steps are grouped for wall-hanging or recessing use. Check the parts list to make sure
nothing is missing. Dispose of packaging materials properly. Please recycle whenever possible.
You will need the following tools (not included): Phillips screwdriver; stud finder; level; tape
measure; electric drill; 1/4” wood drill bit, hammer.
Parts and Hardware
A– Fireplace
B– Wood Screws
C– Drywall anchors
Remote Control
E-Wall Bracket
Fixed on back of firebox
F-Decorative
Pebbles
G-Decorative
Crystals
H - Log set
I - Plastic Tray

4
Specification and Dimension
PRODUCT DIMENSIONS
Model Number
A
B
C
D
E
F
G
VL-36B
36"
91.5cm
21.46"
54.4cm
5.51"
14cm
32.48"
82.5cm
20.51"
52.1cm
12"
30.5cm
30.91"
78.5cm
VL-45B
45"
114.3cm
21.46"
54.4cm
5.51"
14cm
39.88"
101.3cm
20.51"
52.1cm
12"
30.5cm
38.31"
97.3cm
VL-50B
50"
128cm
21.46"
54.4cm
5.51"
14cm
46.85"
119cm
20.51"
52.1cm
12"
30.5cm
45.28"
115cm
VL-55B
55"
139.7cm
21.46"
54.4cm
5.51"
14cm
46.85"
119cm
20.51"
52.1cm
12"
30.5cm
45.28"
115cm
VL-60B
60"
152.4cm
21.46"
54.4cm
5.51"
14cm
46.85"
119cm
20.51"
52.1cm
12"
30.5cm
45.28"
115cm
VL-65B
65"
165.1cm
21.46"
54.4cm
5.51"
14cm
61.5"
156.1cm
20.51"
52.1cm
12"
30.5cm
59.8"
152.1cm
VL-72B
72"
182.8cm
21.46"
54.4cm
5.51"
14cm
68.39"
173.72m
20.51"
52.1cm
12"
30.5cm
66.82"
169.72cm
VL-100B
100"
254cm
21.46"
54.4cm
5.51"
14cm
96.39"
244.83cm
20.51"
52.1cm
12"
30.5cm
94.8"
240.84cm
Installation and Assembly
Your appliance is a wall-mounted, recessed and/or mantel installed appliance. Select a suitable
location that is
not susceptible to moisture and is away from drapes, furniture and high traffic areas.
NOTE: Follow all National and local electrical codes.
MINIMUM CLEARANCE TO COMBUSTIBLES
Measurements are taken from the glass front.
Bottom 0" Top 8" (300mm) to mantel
Sides 0" Top 8" (300mm) to ceiling
Back 0"
Description
Electric Fireplace
Type
3 Way Mounting Unit
Wall-Mount, Recess into
Wall and
Assemble with mantel
Voltage
220V AC
Watts
MAX 1600W
Amps
10 AMP Grounded Circuit

5
MINIMUM MANTEL CLEARANCES
WARNING
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
HEAT RESISTANT TO PREVENT DISCOLOURATION.

6
STEP A. Selection a dry wall to open a hole for fireplace box. Size of hole as below chart
Figure ( A )
Framing Hole Size
Model Number
W
H
VL-36B
33” (83.82CM)
20.75” (52.71CM)
VL-45B
40” (101.6CM)
20.75” (52.71CM)
VL-50B
47” (119.38CM)
20.75” (52.71CM)
VL-55B
47” (119.38CM)
20.75” (52.71CM)
VL-60B
47” (119.38CM)
20.75” (52.71CM)
VL-65B
62” (157.48CM)
20.75” (52.71CM)
VL-72B
69” (175.26CM)
20.75” (52.71CM)
VL-100B
97” (246.38CM)
20.75” (52.71CM)
STEP B. Fix the three wall anchors in each side of the fireplace box according to the dimensions
showed on the drawing. Figure (B)
RECESSED TO WALL INSTALLATION
Hole Size
( A )
( B )
W
H

7
( C ) (D)
STEP C. Take off the two screws in both sides of the glass panel. Figure ( C )
STEP D. Have two person to take the glass panel out of the fireplace box. Place it to a soft and
clean place. Figure ( D)
( E ) ( F )
STEP E. Have two person to move the fireplace box to the wall hole.
If the appliance is fully recessed into the wall:
• Use the 6 screws (provided) to lock the appliance into the wall with the existing two side
flanges, see Figure ( E)
• Install the media and re-install the glass front.
STEP F. Fireplace will be like this after installation Figure ( F)

8
Wall Mounted Installation
Due to the many different materials used on different walls, it is highly recommended
that you consult your local builder before you install this appliance on the wall.
A.Select a location that is not prone to moisture and is located at least 36" (914mm)
away from combustible materials such as curtain drapes, furniture, bedding, paper,
etc.
B.Have two people hold the appliance against the wall to determine the final
location.
C.Place unit face down on a soft, non abrasive surface. Remove the bracket from
the back of the unit by removing the screws, refer to Figure 1.
D.Mark out location, then mount the bracket(s) onto the wall using the supplied
screws. This bracket
MUST have the hooks facing upward and be level. NOTE: It is strongly
recommended that the
mounting bracket (E) be
Screwed into the wall studs
Where possible. If the wall
Studs cannot be used, ensure
That the supplied plastic anchors are used to affix the bracket to the wall and
the bracket is adequately secured.
E. With the wall mounting bracket installed have two people lift the appliance up and
insert the two hooks
on the bracket into the two slots on the back of the appliance.
F. Check the appliance for stability ensuring that the bracket will not pull free from
the wall.
VL-36/45/50/60B Wall Bracket Illustrated

9
Log set / Crystal / Pebble Ember Installation
(NOTE:Please make the installation according to the embers which you bought or selected.)
A. Glass front must be removed and the appliance must be mounted in its final location
before the log set / crystal / pebble embers are installed.
B. If your fireplace come with log set, remove the log set from the package, put it to the fireplace
designed place. Figure 1.
C. If your fireplace come with CLEAN CRYSTAL or PEBBLE MEDIA: Crystal or pebbles media
may have a fine oil residue that needs to be cleaned prior to installation. Clean the them with
mild dish soap, drain, rinse thoroughly and dry before placing into the tray.
D. Place the plastic tray ( I) to the fireplace designed place.Then carefully place crystal or pebbles
embers into the bottom tray on the front of the appliance as illustrated. Apply an even layer
from side to side. Figure 2, Figure 3.
VL-72/100B Wall Bracket Illustrated

10
Figure 1. Figure 2.
Figure 3. (Crystal medias) Figure 3. (Pebbles medias)
Operation
Read and understand this entire owner’s manual, including all safety information,
before plugging in or using this product. Failure to do so could result in electric shock,
fire, serious injury, or death.
Power
Plug the power cord into a 220~240 Volt 10 Amp grounded outlet (see IMPORTANT SAFETY
INFORMATION on Pages 2 and 3). Make sure the outlet is in good condition and that the plug is not
loose. NEVER exceed the maximum amperage for the circuit. DO NOT plug other appliances into the
same circuit.
Methods of Operation
This electric fireplace can be operated by the CONTROL PANEL, located on the UP right side glass
panel slot of the fireplace, or by the battery-powered REMOTE CONTROL.
The operation and functions of the two methods are the same.
Este manual sirve para los siguientes modelos
7
Tabla de contenidos
Otros manuales de Chimenea de interior de visionLINE

visionLINE
visionLINE Circle Instrucciones de instalación

visionLINE
visionLINE VL-VESTA-50 Manual de usuario

visionLINE
visionLINE BG-36B Manual de usuario

visionLINE
visionLINE TAURUS-AU Instrucciones de instalación

visionLINE
visionLINE TAURUS - AU Instrucciones de instalación

visionLINE
visionLINE TAURUS-AU Zero Clearance Manual de usuario

visionLINE
visionLINE VL-24 Manual de usuario