Vision ZL 7261 CL-5 Manual de usuario

Federal Communications Commission Statement
This equipment has been followed to comply with Part 15 of the FCC Rules. This
equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try and correct the
interference by one of the following measures:
-Reorient or relocate the receiving antenna,
-Increase the separation between the equipment and receiver,
-Connect the equipment into and outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesirable operation.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this
equipment.
Limited Warranty
Vision Guarantees that every wireless lighting module is free from physical defects
in material and workmanship under normal use for one year from the date of
purchase. If the product proves defective during this one-year warranty period,
Vision will replace it free of charge. Vision does not issue any refunds. This warranty
is extended to the original end user purchase only and is not transferable. This
warranty does not apply to: (1) damage to units caused by accident, dropping or
abuse in handling, or any negligent use; (2) units which have been subject to
unauthorized repair, taken apart, or otherwise modified; (3) units not used in
accordance with instruction; (4) damages exceeding the cost of the product; (5)
transit damage, initial installation costs, removal cost, or reinstallation cost.
For information on addional devices, plesae visit us at www.visionsecurity.com.tw
-5-
Operation Manual
ZL 7261 CL-5
ZL 7261 CN-5
ZL 7261 DE-5
ZL 7261 FR-5
ZL 7261 IT-5
ZL 7261 JP-5
ZL 7261 KR-5
ZL 7261 RU-5
ZL 7261 US-5
Z-Wave Power Monitor
ZL 7201 CL-5
ZL 7201 CN-5
ZL 7201 DE-5
ZL 7201 FR-5
ZL 7201 IT-5
ZL 7201 JP-5
ZL 7201 KR-5
ZL 7201 RU-5
ZL 7201 US-5
Z-Wave On/Off Module
ZL 7261/7201 V5
1050902 6B1Z-72003

Introduction
Thanks for choosing the Vision’s Power Monitor or On/Off Module of the home automation device. This
Power Monitor or On/Off Module is a Z-Wave TM enabled device (interoperable, two-way RF mesh
networking technology) and is fully compatible with any Z-Wave TM enabled network. Every main powered
Z-Wave TM enabled device acts as a signal repeater and multiple devices result in more possible
transmission routes, which helps eliminate “RF dead-sport”.
Z-Wave TM enabled devices displaying the Z-Wave TM logo can also be used with it regardless of the
manufacturer, and ours can also be used in other manufacturer’s Z-Wave TM enabled networks. This
module will send On/Off signal to the appliance that attached to this module by receiving Z-Wave TM
signal from controller or manually switch. It also sends the energy consumption (ZL7261 only) to the
controller when it requests. With special design, this module won’t interfere the other power outlet when
plug into the AC outlet. This module also acts as repeater (supporting FLiRS).
Product Description and Specification
Specification:
Package Content:
Protocol: Z-Wave
TM
(ZM5202)
Frequency:
868.42 MHz (ZL7201CN/DE/FR/IT / ZL7261CN/DE/FR/IT)
869.00 MHz (ZL7201RU / ZL7261RU)
908.40 MHz (ZL7201CL/US / ZL7261CL/US)
919.70 MHz (ZL7201KR / ZL7261KR)
922-926MHz (ZL7201JP / ZL7261JP)
Operating Temp. -15°C~ 60°C (-5°F~ 140°F)
Operating Voltage: AC 100V~230V
Operating Range: Up to 100 feet (about 30m)
Data Rate: Up to 9.6k/40k/100kbps
Application: Indoor use
Max Loading
Type B: 110V/15A/1600W (Resistive)
220V15A/3200W (Resistive)
Type E, F & L: 230V/10A/2300W (Resistive)
1pc Power Monitor or On/Off Module
1pc User Manual
Z-Wave™ Command Class:
COMMAND_CLASS_APPLICATION_STATUS
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_METER_V4 (ZL7261 only)
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_PROTECTION (ZL7201 only)
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SWITCH_ALL
COMMAND_CLASS_SWITCH_BINARY mapping COMMAND-CLASS_BASIC
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_ZWAVEPLUS_INFO
Operation
If you are installing the entire Z-Wave TM system for the first time, please refer to the
installation guide of Z-Wave TM Interface Controller before installing ZL7261 or ZL7201.
1. For “Inclusion” in (adding to) a network: Put the Z-Wave TM Interface Controller into
“inclusion” mode, and following its instruction to add the ZL7261 or ZL7201 into your
controller. To get in the “Inclusion” mode, by power up to get included for first time, or
press the Program switch 3 times within 2 seconds to be included.
For “Exclusion” from (removing from) a network: Set up the Z-Wave TM Interface
Controller into “exclusion” mode, and following its instruction to delete the ZL7261 or
ZL7201 from your controller. Press the Program Switch 3 times within 2 seconds to
be excluded.
For “Association”: the Z-Wave TM interface controller set “Association”, and following its
instruction to associate the ZL7261 or ZL7201 with other device. Support one group (5
nodes). ZL7261 or ZL7201 will report back every time ON and OFF status, also it will
reports every notification to all devices in the association group.
-2-
-1-
**For making better effect, please press the button as the direction of following diagram.

2. For “Meter Supported Get” (ZL7261 only): the Z-Wave TM Interface Controller or Gateway
can send “Meter Get” command with any of the following supported scales, and the
ZL7261 will report back with the energy consumption values for the requested scale:
Scale: 0x00-kWh(Default);
0x01-kVAh
0x02-W
0X04-V
0X05-A
0X06-Power Factor.
3. LED visual indication:
Excluded Red and Green LED flashing separately
Included Switch ON Red, Switch Off Green ZL7201 only
Energy
0 ~ 5 AMP Green ZL7261 Type
B plug only
5 ~ 10 AMP Orange
10 ~ 15 AMP Red
0 ~ 3 AMP Green ZL7261 all
other plug
only
3 ~ 7 AMP Orange
7 ~ 10 AMP Red
4. Manually turn the connected appliance On/Off by your controller or pressing the Program
Switch. This is toggle switch. If the connected appliance is OFF, pressing the
Program Switch turns the connected appliance ON and vice versa.
5. The on/off function uses the Z-Wave Switch Binary Command Class (or Basic Command
Class) to control its operation. Sending a switch binary set command with a level of 0
(0x00) will turn off the device, and sending a level of 255 (0xFF) will turn on the device.
6. Repeater Function: This device acts as a repeater for the Z-Wave mesh network
functionality.
7. Support AES Function Support AES Function. Security enabled Z-Wave controller must
be used to fully utilize the product.
8. Support Meter Auto Report Function (ZL7261 only)
9. Configuration (ZL7261 only):
Parameter
Size
Value Notes
Auto report
timing 1 1 byte
60~255 seconds
(Default 60 seconds) Report kWh/kVAh
Report when
Watt change 2 2 byte
5-3600 watt for Type B
plug
5~2300 watt for all
other plug
(Default 50 watt)
Report V.A.W
10. Protection function (ZL7201 only)
Protection State Program Switch Notes
0x00 1 times (Default)
0x01 4 times Within 2 seconds
0x02 Off
11. Reset: Press the Program Switch then power on (plug-in) and hold for 5 seconds before
release the switch. Only use this procedure when the primary controller is lost or
otherwise inoperable.
12. Support OTA (Over-the Air) Firmware update from controller. Please refer to your
controller manual. Once OTA function success, please make sure to exclude the device
& include again before using the device.
13. Overload Protection: If load is excess 15.5A for Type B plug or 10.5A for all others, then
relay will automatically cut off. To restore the relay, please power off & power on the
device again.
-3-