VET Slim Manual de usuario

INSTRUCTION MANUALINSTRUCTION MANUAL

TABLE OF CONTENTS
www.vetlubrication.com
GENERAL INFORMATION 3
1. VET SLIM GENERAL SYSTEM OVERVIEW 4
2. OPERATING OF THE VET SLIM PUMP 5
3. VET SLIM BASIC OPERATING PRINCIPLE 6
4. THE FIXED PUMPING ELEMENT 7
THE MULTI-LINE PUMPING ELEMENT 8
6. THE ADJUSTABLE PUMPING ELEMENT 9
7. FILLING THE RESERVOIR 10
8. ELECTRICAL CONNECTIONS 11
9. SETTING THE TIMER 12
10. DIMENSIONS 17
11. SPARE PARTS & ACCESORIES LIST 21
12. ARTICLE NUMBER CONFIGURATION 22
2/23

GENERAL INFORMATION
www.vetlubrication.com 3/23
This is an instruction manual for the VET Slim compact automatic grease pump.
An automatic greasing system from VET lubricates your machine or vehicle with the right
amount of grease, while you are using the machine or vehicle. The users only responsability
is to fill the grease reservoir.
To maintain the durability of the automatic greasing system, it is important that you adhere
to the following rules:
Install the components correctly.
Use the correct grease.
Check the device regularly.
CONSEQUENCES WHEN NEGLECTING GUIDELINES
If there is not enough grease in the appliance or if you do not refill the pump regularly, the
machine or vehicle may be damaged. VET Lubrication B.V. is not liable if damage occurs.
Are you using incorrect or contaminated lubricants, are you changing something on the
device yourself or are you not using the right parts for a repair? Then the warranty expires.
FOR YOUR SAFETY
For your own safety, you must adhere to one important rule; Switch
off the device completely during maintenance or repair work.

1. VET SLIM GENERAL SYSTEM OVERVIEW
3
1
4
5
2
6
8
7
10
9
1. Electric grease pump
2. Transparant reservoir
3. Grease filling port
4. Pumping elements
5. Inspection window
6. Progressive main divider
7. Progressive secundary divider
8. Main hoses
9. Lubrication points
10. Secundary hoses
www.vetlubrication.com
4/23

2. OPERATING OF THE VET SLIM PUMP
The electric pump pumps the grease to the progressive main distributor. This main distribu-
tor distributes the grease in the right quantities over the different lubrication points or se-
condary distributors. Pistons force the grease in a certain direction, so that it cannot choose
the path of least resistance. This ensures good control over the entire lubrication system.
With the control panel you control the lubrication and pause time so that your machine or
vehicle is lubricated optimally.
Minimum level
8 pumping unit
Max Level
Identification label
Minimum level
Cycle sensor
connector M12
AMP 7 pin power
supply connector
Inspection window
“Progressive”pumping
unit fitting (M22x1.5)
Position 1
Reservoir (1.5/2.5/4L)
Stirring paddle
Recycling fitting
(G1/8”)
8 pumping unit
fitting (M12x1)
Grease filling port
“Progressive”
pumping unit
fitting (M22x1.5)
Position 2
www.vetlubrication.com 5/23

3. VET SLIM BASIC OPERATING PRICNIPLE
The VET SLIM grease pump is driven by a 12VDC or 24VDC electrical motor. An eccentric
disc is mounted to this electric motor. The eccentric movement of this disk pushes the piston
from the pump element back and forth. The electric motor is controlled by an internal or
external control/timer.
Piston from the
pump element
Eccentric
disk
www.vetlubrication.com
6/23

4. THE FIXED PUMPING ELEMENT
The pump element is a crucial part of the automatic lubrication system. It is so important
because the pump element builds up the pressure in the greasing lines. The eccentric disk
pushes every revolution against the piston of the pump element. This forces grease into
the greasing lines. When the eccentric disc does not push against the plunger, the chamber
of the pump element is filled with grease. Repeating this several times creates a pumping
effect.
The pump element is provided with an optional pressure relief valve. When a lubrication
point gets blocked somewhere in the system, too much pressure will build up in the system.
Then grease will be let out of the internal pressure relief valve. This makes it easy to see if
something is wrong with the lubrication system. The pump will give an electronic warning
when the overflow is triggered.
The pump element wears during use. If the pump element is worn, it will no longer pumps
grease. When the grease level in the reservoir does not drop. You must replace the pump
element.
The VET SLIM pump is standard delivered with a 0.12 cm3 per stroke pumping element. The
output per minute is 2.4 cm3 /min.
4.1. INSTALLING THE PUMPING ELEMENT
1. Unscrew and remove the plas-
tic plug with the O Ring that
is installed on the standard
product.
2. Insert and screw the pump
element until it is fixed in
position.
3. Use 20Nm torque to secure the
element.
M22x1,5
Outlet
G1/4”
Notches
1 notch
2.4 cm3/min
2 notches
4.4 cm3/min
www.vetlubrication.com 7/23

5. THE MULTI-LINE PUMPING ELEMENT
The multi-line pumping element is normally used to directly lube a single lubrication point
without the use of dividers. This option will reduce the costs of a system in certain situati-
ons. The operating principle of the multi-line pumping element is comparable to the opera-
ting principle of the fixed pump element with a lower grease output. The grease output of
the multi-line puping element ranges from 0.09 cm3/min to 0.85 cm3/min.
5.1. INSTALLING THE MULTI-LINE PUMPING ELEMENT
1. Unscrew and remove the plastic plug with the O Ring that is installed on the standard
product.
2. Insert and screw the pump element until it is fixed in position.
3. Use 20Nm torque to secure the element.
1 notch
0.09 cm3/min
2 notches
0.17 cm3/min
3 notches
0.26 cm3/min
4 notches
0.43 cm3/min
5 notches
0.85 cm3/min
www.vetlubrication.com
8/23

6. THE ADJUSTABLE PUMPING ELEMENT
To set the precise output of the second pump element, or to set the output of a pump
without controller,
an adjustable pumping element can be added to one of the outlets of the pump.
TO SET THE PROGRESSIVE PUMPING UNIT WITH ADJUSTABLE
FLOW, PROCEED AS FOLLOWS:
Ensure there is no residual pressure in the grease line.
Remove the adjustment access cap using a 4 mm Allen wrench.
Insert the Allen wrench in the exposed grub screw.
Rotate the screw clockwise until it can’t go further.
Rotate the screw counterclockwise to reduce the output.
Every rotation equates to approximately 0.52 cm3/min. With four possible rotations
the minimun amount is 0.32 cm3/min and the maximum is 2.4 cm3/min.
Check if the copper gasket is present and in good order and replace if necessary.
Reinstall the cap using a 4 mm Allen wrench.
Piston
M22x1.5
Output
g1/4”
Adjustment
acces cap
www.vetlubrication.com
4.1. INSTALLING THE PUMPING ELEMENT
1. Unscrew and remove the plastic plug with the O Ring that is installed on the standard
product.
2. Insert and screw the pump element until it is fixed in position.
3. Use 20Nm torque to secure the element.
9/23

7. FILLING THE RESERVOIR
The grease reservoir can be filled in three different ways:
FOR MANUAL FILLING OF THE GREASE RESERVOIR WITH THE
MANUAL FILLING SYRINGE, THE FOLLOWING STEPS MUST BE
FOLLOWED.
Manually
Pneumatic
Electrical
NOTE:
Make sure the grease filling syringe and refill
fitting are clean before filling the reservoir. Dirt
in the system will cause various problems.
STEP 1:
Unscrew the red protection
cap.
STEP 2:
Press in the filling syringe
firmly into the refill fitting and
gently empty the syringe.
STEP 3:
Screw the red protection cap
back on.
www.vetlubrication.com
10/23
Tabla de contenidos
Manuales populares de Bomba de agua de otras marcas

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guía de solución de problemas

DUROMAX
DUROMAX XP WX Series Manual de usuario

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manual de usuario

Franklin Electric
Franklin Electric IPS Manual de usuario

Xylem
Xylem e-1532 Series Manual de usuario

Milton Roy
Milton Roy PRIMEROYAL Manual de usuario