Veris P4000 Manual de usuario

2-1
P4000 DW-EC-Force Probe
Table of Contents
Section 1
1-1 Warranty & Safety
Section 2
2-1 System Overview P4000
2-3 System Overview Electronics
2-10 Model Year 2018 and newer Electronic additions
2-11 Procedure # 1 Establishing Bluetooth Connectivity
Section 3
3-1 Software Installation Guide
Section 4
4-1 Field Operations –Electronics
Section 5
5-1 Probe Platform Installation—skid units
5-3 Platform Operation
5-4 DW-EC-Force Probe Operation
5-6 Soil Coring
5-8 Soil Anchoring System
5-10 Probe Removal and Tractor Installation
Section 6
6-1 Maintenance and Lubrication
6-4 Probe Removal
6-5 Instrument Removal
Section 7
7-1 Troubleshooting
Section 8
8-1 Specifications
Operating Instructions

2-2
Warranty
Veris Technologies warrants this product to be free of defects in materials and
workmanship for a period of one (1) year from the date of delivery to the purchaser.
Veris Technologies will repair or replace any product returned to Salina, Kansas, which
appears upon inspection to be defective in materials or workmanship. Veris
Technologies will have shall have no obligation under this warranty for the cost of labor,
down-time, transportation charges, or for the repair or replacement of any product that
has been misused, carelessly handled, modified, or altered.
ALL OTHER WARRANTIES OF ANY KIND, WHETHER EXPRESSED OR IMPLIED,
INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE AND ALL
CLAIMS FOR CONSEQUENTIAL DAMAGES, ARE SPECIFICALLY DISCLAIMED AND
EXCLUDED.
Safety

2-3
Important! Read the following SAFETY PROCEDURES before operating the Veris
P4000
• Probing into buried electrical, gas, sewer, communication and other utilities can cause
death, serious injury, and significant property loss. Utilize ‘call before you dig’ services.
• Pinch point hazard: to prevent injury, stand clear when raising or lowering any part of
the Veris P4000.
• Install all transport locks before transporting or working underneath.
• Detach and store implements in an area where children normally do not play. Secure
implement by using blocks and supports.
• Keep feet clear of foot and probe when lowering.
• Do not probe where utility lines may be present. Use ‘Call Before You Dig’ services.
• Use paper or cardboard, NOT BODY PARTS, to check for suspected leaks.
• Wear protective gloves and safety glasses or goggles when working with hydraulic and
high-pressure wash systems.
• If an accident occurs, see a doctor immediately. Any fluid injected into the skin must
be surgically removed within a few hours or gangrene may result.
• Read Operations Manual before operating machine
• Review safety instructions with operators before operating machine and at least
annually
• Riders obstruct the operator’s view. They could be struck by foreign objects or
thrown from the machine.
• Never allow children to operate equipment.
• To prevent possible electrical shock, or damage to the instrument, do not connect to
any power source greater than twelve (12) volts DC.
• Do not grease or oil implement while it is in operation.
• Disconnect battery ground cable (-) before servicing or adjusting electrical systems or
before welding on implement.
• Remove buildup of mud, oil or debris.
• Be prepared if a fire starts
• Keep a first aid kit and fire extinguisher handy.
• Be careful when touching the probe after use, the sapphire window gets hot.
Section 2

2-4
VERIS P4000 Probe Platform
System Overview
Before you begin using your P4000, it’s important to familiarize yourself with the basic
components and controls
Pre-operation checks:
1) Engine oil Level –refer to Honda GX 670 engine manual
2) Hydraulic fluid -- fluid level should be at or near upper black line on sight gauge
of hydraulic reservoir. (Figure 1). If not add suitable ISO 32 hydraulic fluid with a
viscosity index of 95- 140. Unit is filled at factory with Mobilfluid 424.
3) Check gas level –unleaded gasoline only
4) Check for any loose fasteners or hydraulic leaks.
Controls:
1) Engine controls are located on the engine itself. (figure 2) . Refer to Honda
engine manual for detailed information.
Hyd sight
gauge
Fuel Tank
Figure 1
Starter Switch
Choke
Throttle
Figure 2

2-5
Hydraulic Controls
All system monitoring and probe control functions are contained on the
console mounted to the right of the probe, referred to as the “foot”. (Figures 3,4)
a) Voltage meter –monitors battery voltage
b) Side shift control –allows lateral movement of probe for multiple insertions at
a given location.
c) Extension control -- used to extend probe from transport to field use position
d) Fold control –folds probe from transport to use position
e) Probe speed flow control –controls insertion speed of NIR/EC Force Probe to
operator preference
f) Hydraulic pressure gauge –monitors system pressure during hydraulic
cycling
g) Hour meter—monitors engine operation for routine maintenance
h) Foot Control –Raises and lowers foot
i) Rotation control –aids in soil core insertion in tough soils. Down is clockwise-
direction required for coring.
j) Probe control –Raises and lowers probe assembly
k) Engine emergency stop –immediately shuts down engine if need arises.
l) 12VDC power switch for OpticMapper Instrument.
Figure 3
Figure 4
Voltage meter Side Shift control Extension control Fold control
Probe speed
Flow control
12v power switch Engine emergency stop Probe control Rotation control Foot control
Hyd pressure gauge
Engine hour meter

2-6
Electronics
System diagram
Figure 7

2-7
OM Com/GPS Input
Serial communication to PC and GPS
input with cable #49494
12V Power
Power cord shipped with the unit that
connects to the vehicle’s battery
On/Off
Turns power to
OpticMapper
Controller
On/Off
3A Fuse
Power
Indicator
Indicates when
power to the
controller is on
Trigger
Sets starting
depth point on
when logging
Depth
Stringpot cable
connects here
to track probe
depth
EC
Connects to EC
connection
coming from
probe
Optic Power
Delivers
power to LEDs
and receives
the force
signal input
Figure 8
Figure 9

2-8
Figure 12
Figure 13
Cable that includes force, EC and
optical connections
Garmin GPS
# 21221
Power cable
#39985
This is used to power the
instrument from a vehicle (for
field use).
Note: Only use 5-amp fuse
Garmin external GPS
Note: for model years 2018 and
newer this is not supplied as there
is an internal GPS source on the
V.Sense Controller
Optical sensor
Electrical Conductivity (EC) contacts
Figures 10 & 11

2-9
String Pot #SC160
String Pot Cable
Connects stringpot to
instrument
USB-Serial
Converter
Figure 15
Optical testload
connects to
Optical port on
instrument to
simulate optical
readings to test
instrument
EC testload
connects to EC port
on instrument to
simulate EC readings
to test instrument
EC Dipole tester
connects between
the brass pin and EC
tip to simulate EC
readings
OM Reference block
Used to simulate light
and dark readings for
optical sensor
Figure 14

2-10
Model Year 2018 and newer Electronic additions
2018 and newer model years use a V.Sense controller in place of the EC OM
Controller. This offers similar functionality; however there is the addition of a Bluetooth
connection, and internal GPS. The controller will default to use the internal GPS signal;
however if an external GPS signal is provided via the GPS input connector then the
external signal takes priority. See the Bluetooth pairing (procedure #1 on following
page) for additional information on Bluetooth connectivity.
Note: No connection is necessary for the U3 COMM Port when using the V.Sense
Controller
GPS
Bluetooth
Antenna
Figure 16
Tabla de contenidos
Otros manuales de Maquinaria agrícola de Veris
Manuales populares de Maquinaria agrícola de otras marcas

GSi
GSi PNEG-2314 Manual de usuario

Checchi & Magli
Checchi & Magli TEXDRIVE Manual de usuario

Amazone
Amazone Cenius 4003-2TX Manual de usuario

MASSEY FERGUSON
MASSEY FERGUSON MF 9313S Manual de usuario

Cima
Cima BLITZ Instrucciones de funcionamiento y mantenimiento

Amazone
Amazone CombiDisc 3000 Instrucciones de instalación