Note : If you are using this Voice Dialler with our alarm system
having 256 ID code combinations, (that is when the system
ID code switch block of the alarm system has only 2
positions, up being the ON position and down being the OFF
position), please not the down position marked as "-" of the
Voice Dialler can’t be used. Only the up and middle position
can be used.
Voice Dialler (6561 codes) Alarm System (256 codes)
UP (+) = UP (ON)
MIDDLE (o) = DOWN (OFF)
DOWN (-) not used
3) Set the tone/pulse jumper
If your telephone system uses tone dialling, make sure the tone/pulse
jumper is shorted (with a clip between them). If your telephone
system uses traditional pulse dialling, pull up the clip (jumper should
be opened).
4) Close the protective cover.
5) Hang the Voice Dialler on the wall or put the Voice Dialler on top of
the table by using the appropriate bracket.
6) Plug the cord of the AC adapter into the DC jack.
7) Plug the AC adapter into the wall outlet. You will hear a beep sound
and the RDY LED (green LED) will start flashing. The Voice Dialler
is now ready for operation.
5. Basic operation
Notes :
A. When pressing any key, you will hear a beep, this lets you know
the keystroke has been accepted.
B. When entering keystrokes, the interval between two keystrokes in
a setting sequence must not exceed 5 seconds, otherwise, the keys
you have entered earlier will be ignored and the Voice Dialler
will return to idle.