urmet domus IPerCom-2Voice Manual


IPerCom-2Voice system schematic Page 1
IPerCom-2Voice combined with iPassan access control system schematic Page 2
Network installation and configuration requirements Page 3 & 4
2Voice riser installation Page 4 & 5
System connections Page 6 & 7
DIP switch settings Page 8 & 9
2Voice riser connection and installation rules Page 10 & 11
2Voice fault finding Page 12 & 13
1750/1 Miro video monitor
Controls Page 14
Installation Page 15
Connections Page 15
1750/5 or 1750/6 Miro hands-free video monitor
Controls Page 16
Installation Page 17
Connections Page 18
1183/5 Miro audio handset
Controls Page 19
Installation Page 19
Connections Page 20
1183/7 Miro hands-free audio station
Controls Page 21
Installation Page 22
Connections Page 22
Contents

1060/13 Elekta, 1060/18 & 1060/19 Elekta Steel Call Modules
Connections overview Page 23
Maglock connection example Page 24
Fail safe and fail secure release connection examples Page 25
Interface to iPassan and third party access control systems Page 26
1060/18 & 1060/19 Mounting height Page 27
1060/13 Mounting height Page 28
1060/74 Sinthesi Steel Entry Panel
Connections overview Page 29
Maglock connection example Page 30
Fail safe and fail secure release connection examples Page 31
Interface to iPassan and third party access control systems Page 32
Mounting height Page 33
1060/82 Proximity Key Reader
Connections overview Page 34
Maglock connection example Page 35
Fail safe and fail secure release connection examples Page 36
Mounting height Page 37
1060/84 Relay Module Page 38
1060/41 Switchboard Handset Page 39
DIP switch settings Page 40 & 41
Notes Page 42
Contents continued

IPerCom
-
2Voice schematic
U R MET
U R MET
U R MET
U R MET
U R MET
U R MET
U R METU R MET
This schematic shows
the IPerCom video entry
system with integrated
IPerCom proximity
access control
Cat5e
Cat5e
Cat5e
IP Network
Doorbell push button
Extension sounder
2-Core cable
2-Core cable
2-Core cable
2-Core cable
2-Core cable
2-Core cable
4-Core cable
1060/82
Lock power supply
Exit switch
Break glass
Maglock
1060/84
2-Core
cable
2-Core
cable
2-Core
cable
2-Core
cable
Input 1
-
From third party equipment
Output 1
-
To third party equipment
Input
2
-
From third party equipment
Output
2
-
To third party equipment
Lock power supply
1060/74
4-Core cable
2-Core cable
2-Core cable
2-Core cable
2-Core cable
1060/13
1060/18
1060/19
Lock power supply
Maglock
Exit switch
Break glass
Maglock
2-Core cable 2-Core cable
2-Core cable
4-Core cable
Exit switch
Break glass
2-Core cable
1
Cat5e
Cat5e
Cat5e
Cat5e
Cat5e
1083/20 1083/59
1083/55
1083/55
230V
230V
230V
230V
Maximum distance from
1083/20..1083/59 to the
furthest monitor or
handset is 125M
Maximum distance from
1083/55 to monitor or
handset is 50M

U R MET
U R MET
U R MET
U R MET
U R MET
U R MET
U R MET
U R MET
IP Network
2-Core cable
Cat5e
Exit switch
Break glass
Maglock
1060/13
1060/18
1060/19
Cat5e
Cat5e
Cat5e
Cat5e
Cat5e
Maglock
Maglock
Exit
switch
Break
glass
Break glass
Exit switch
iPassan
controller
(including
power supply)
iPassan
controller
(including
power supply)
Cat5e
Cat5e
2-Core cable
2-Core cable
4-Core cable
2-Core cable
4-Core cable
2-Core cable
2-Core cable
2-Core cable
2-Core cable
2-Core
cable
4
-
Core cable
2
iPassan reader
iPassan
reader
iPassan
reader
1060/74
Cat5e
IPerCom
-
2Voice with iPassan schematic
iPassan
controller
(including
power supply)
This schematic shows
the IPerCom video entry
system with iPassan
proximity access control
1083/55
1083/55
Cat5e
Cat5e
Cat5e
2-Core cable
2-Core cable
230V
230V
230V
230V
1083/59
1083/20
Maximum distance from
1083/20..1083/59 to the
furthest monitor or
handset is 125M
Maximum distance from
1083/55 to monitor or
handset is 50M

The installation should be installed, tested and documented as per the following standards –
European Committee for Electrotechnical Standardisation (CENELEC)
EN 50173 Information Technology – Generic Cabling Systems
EN 50173-1:2011 General requirements
EN 50173-2:2007 + A1:2010 Office Premises
EN 50173-3:2007 + A1:2010 Industrial Premises
EN 50173-4:2007 + A1:2010 Residential Premises
EN 50173-5:2007 + A1:2010 Data Centers
EN50173-6: Distributed Building Services
CENELEC also produce the EN50174 series of standards that are concerned with the way in which cabling
systems are designed and installed –
EN 50174-1:2009 + A2:2004
Specification and Quality Assurance
EN 50174-2:2009 + A2:2004 Installation planning & practices inside buildings
EN 50174-3:2013 Installation planning & practices outside buildings
Another relevant CENELEC standard is –
EN 50310:2010 Application of equipotential bonding and earthing in
buildings with information technology equipment
British Standards Institute (BSI)
BSI adopts all CENELEC standards and prefix them with their authority code, i.e. EN 50174-1:2009 +
A2:2004 becomes BS EN 50174-1:2009 + A2:2004
BSI also produces its own national standards –
BS 6701:2010 Telecommunications equipment and telecommunications cabling.
Specification for installation, operation and maintenance.
BS 7671 Requirements for Electrical Installations. IET Wiring
Regulations (18th Edition).
BS6701:2010 states: All telecommunications cabling and telecommunications equipment shall meet the
requirements of the BS EN 50174 series of standards. This relates to both owners of premises (Clause 4)
and installers of telecommunications cabling and telecommunications equipment (Clause 5). Note that
the use of the word ‘shall’ is prescriptive and as such, is a legal requirement.
Urmet recommends adherence to the BS EN 50173 and BS 50174 series of standards, together with the
relevent parts of BS 6701 and BS7671 to ensure a fully compliant installation that conforms to UK legal
requirements. It is the responsibility of the installer to ensure that their practices are in accordance with
the latest published editions of the relevant standards.
3
Network installation and configuration requirements

Specific network requirements for IPerCom are as follows –
Specific installation requirements for the 2Voice riser –
IGMPv2
or
IGMPv3 Multicast Service
must be
enabled.
The following ports must be open and not restricted –
TCP ports 2049, 51234, 5060, 50118, 3306, 13451 to 3460, 111, 80, 433, 41365, 22,
918 & 40279.
UDP ports 32768, 2049, 514, 32771, 34956, 917, 34839, 67, 5060, 69, 975, 111, 123.
Multicast must be enabled on 238.0.0.200:55000 and on 239.255.0.200 (all ports).
TCP/UDP ports used for Internet access (if any) TCP:5060,6060 UDP:5060,6060.
Bandwidth per end point (Kbps) 2500 for upload and 10000 for download.
C
U R MET
E
B
J
U R MET
A
U R MET
F
U R MET
U R MET
U R MET
D
I
U R MET
G
U R MET
H
When adding all of the branches together in
the riser (A + B + C….+ J) the maximum total
amount of cable must not exceed 800M.
Additional 1083/59 Gateways can be installed
to achieve installations where more than
800M of cable is required.
As a general guide, after every 50 monitors
another 1083/59 (and 1083/20) should be
used – See example on Page 5
IP
network
4

5
U R MET
U R MET
U R MET
U R MET
U R MET
U R MET
U R MET
U R MET
U R MET
U R MET
U R MET
U R MET
U R MET
U R MET
U R MET U R MET
230V
Cat5e
230V
Cat5e
Cat5e
Cat5e
Cat5e
Cat5e
Cat5e
Cat5e
This method is used where there are
more than 50 monitors in a building.
Any number of 1083/59 Gateways and
1083/20 Power Supplies can be used to
increase the number of monitors in a
building as required.
1083/20 1083/59
1083/59
1083/20
1 2
3 4
49 50
51
100
IP network

System connections
0 110-230~
PRI 110-230V ~ 50/60 Hz 80W CLASS 2 WIRING
SEC LINE 1-2 48V 0.9A+0.4A int
Sch./Ref.
1083/20A
CAUTION
LINE 1 LINE 2
POWER LINE 1 LINE 2 IN 0 IN 1
2VOICE STATUS LED
SD
CARD
LAN
POE
IPERCOM
PROGR./ RESET
GAT EW AY
1083/59
+
-
STATUS LED
IP network
230V AC
2Voice system
connections are
non-polarised
To
LINE IN
of the
1083/55 Distributor
6
Tabla de contenidos
Otros manuales de Controladores de acceso IP de urmet domus