UGREEN CM292 Manual de usuario

5-Bay 3.5” RAID
Hard Drive Enclosure
Model: CM292
English 01-12
Deutsch 13-24
Français 25-36
Español 37-48
Italiano 49-60
Pуская 61-72
日本语 73-84
中文 85-96

ContentsEN
I Notice of Use
1 Preface
2 Notice
II Product Introduction
1 Package Contents
2 Product Overview
3 LED Indicator
4 Specification
III Installation Steps
1 Take Out The Tray
2 Hard Drive Installation
2.1 3.5-inch Hard Drive
2.2 2.5-inch Hard Drive
3 Put Drive Tray Back Into the Enclosure
4 Plug the Device Into Power Outlet
IV RAID Mode Setting and Connection
1 Switch RAID Modes
2 RAID Modes & DIP Switch
3 Drive Partitioning and Formatting
V Other Settings
1 Add New Drives
2 Replace the Broken Drive
01
01
01
02
03
03
04
04
04
05
06
07
08
09
10
11
11
VI Notes

Thank you for purchasing UGREEN products. For optimum operation, please read this manual
carefully before using.
NameNO. Icon Description
Drive Indicator (×5)
v
RAID DIP Switch
RESET
USB-C
DC Power Supply
z
y
Power Indicator
{
w
x
Power Button
|
I Notice of Use
1 Preface
II Product Introduction
1 Package Contents
2 Product Overview
· Please back up all your data before using the product.
· Formatting needed when switching RAID mode or partitioning drives, please back up your
data.
· Please safely eject the hard drive from your laptop/PC in case of data loss.
· Do not unplug the hard drive when copying data in case of file loss or drive damage.
· If there is any loss, corruption of data caused by improper operation or deliberate damage,
the data restoration will not be covered by the warranty. Make sure to back up your
important data regularly.
2 Notice
1×User ManualScrewsScrewdriver
1×5-Bay 3.5'' RAID Hard Drive Enclosure 1×Power Adapter 1×USB-A+C to USB-C Cable
USER MANUAL
Indicates status of each hard drive
For mode setting switch and 8 kinds of array
modes; with different RAID modes come different
DIP combinations
(See "RAID Modes & DIP Switch" for details)
When changing RAID array modes, you'll have to
use this button to reset, and then create a new RAID
mode
Data transfer port for connecting to PCs/laptops
Please use the standard power adapter to power up
the product
Indicates the working status of the device
Press and hold for 3 seconds to power on
Press and hold for 3 seconds to power off
1 2 3
ON
123
ON
2 3 4 5 6 87
01 02

USB-C
(7+15) Pin SATA×5
USB 3.0
5Gbps (Max)
PM/RAID 0/RAID 1/RAID 3/RAID 5/RAID 10/Large/Clone
2.5/3.5-inch SATA interface HDD or SSD
Input
Output
USB Standard
Transfer Rate
Supported Array Modes
Supported Drive Type
Supported Drive Protocol
Transfer Protocol
SATA protocol
UASP
Outer Shell (PC+ABS)+metallic UV
Compatible Operation Systems Windows/macOS/Linux
Dimension L249×W151×H205(mm)
Squeeze the tray handle then pull the tray out.
① Remove the fixing plates, then put the hard drive on the drive tray.
Pins of the hard drive face down.
III Installation Steps
1 Take Out the Tray
2 Hard Drive Installation
3 LED Indicator
4 Specifications
LED Indicator Status Description
Drive
Power
No drive access
Drive access (normal)
Drive access (abnormal)
Drive reading and writing
Solid red
Off
Solid white
Power on
Power off
Solid red
Off
Solid white
Solid white
White flash
Drive safety ejected
Hibernation
Change a new
drive and back up
Solid white New drive backup
accomplished
Red & white
flash alternately
RAID1/3/5/
10/Clone
Modes
2.1 3.5-inch Hard Drive
Pins of the hard drive
03 04

② Put the 2.5-inch hard drive on the drive tray.
Pins of the hard drive face down.
② Install back the fixing plates and be careful of their direction. ③ Flip the tray over and make sure that the four holes of hard drive align with those of the
tray, then screw the hard drive firmly.
Put the drive tray back into the enclosure, then slowly push it to the SATA port.
3 Put Drive Tray Back Into the Enclosure
① As the following picture, remove one of the plates first.
2.2 2.5-inch Hard Drive
Do not unplug the hard drive when the device is powered on, please follow the steps below:
① Safely eject the hard drive from your PC/laptop.
② Turn the device off and take out the hard drive.
Warning
Pins of the hard drive
05 06

· Connect the enclosure to your PC/laptop via the provided cable, then connect to the power
adapter.
· Power on the device, the power indicator turns solid red.
4 Plug the Device into Power Outlet
· Power off: press and hold the power button (about 3 seconds) until the power indicator
goes off.
· Select an array mode based on Array Modes Diagram, and adjust the DIP switch "1/2/3"
respectively.
· Hold "RESET" and long press the power button (about 3 seconds) to turn it on; after 15
seconds release the RESET button. The mode change succeeds if the drive indicator flashes
white.
· Go to "This PC"> "Manage" > "Computer management" > "Device manager", then check the
current RAID mode.
Switching for the first time
Non-standard or non-certified adapters are not allowed in case of the potential risks.
Warning
IV RAID Mode Setting and Connection
1 Switch RAID Modes
· It is recommended that you use each brand new hard drive of the same capacity.
· If you use an old hard drive, please format it before switching the RAID mode, and back up all of
your important data.
· The default mode of the product is PM mode.
· Switch back to PM mode first when you need to change modes, then switch to the RAID mode
you prefer.
Warning
Vhsffo!Mbshf!VTC!Efwjdf
Efwjdf!Nbobhfs
07 08

2 RAID Modes & DIP Switch
A RAID mode formed by RAID 0 read & write speed + RAID 1 safety.
Two disks form a RAID 1, then two sets of RAID 1 form a RAID 0.
When two disks fail at the same time but they're not in the same RAID 1, then the data can still be readable.
Best security, average read and write speed and smallest available capacity.
Take the min. capacity disk as the main one, then clone data to the other disks, all of the disks share the same
data. When one disk fails, all the others will not be affected.
Largest available capacity, average read and write speed, and low security.
All hard drives form a big drive, when one of them fails, all of your data will be unrecoverable.
Default factory setting mode, all disks work separately.
When one disk fails, all the others will not be affected.
RAID 10 ON ON OFF
OFF ON ON
ON OFF ON
OFF OFF OFF
4
2
2
2 × Min.
drive capacity
Min. drive
capacity
Total hard
drive capacities
1Total hard
drive capacities
Clone
Large
PM
Fastest read and write mode, largest capacity but low security.
When one of the hard drives fails, all of the data cannot be restored.
High security, acceptable read and write with small capacity.
When one hard drive fails, other drives work normally; then you'll have to replace the broken drive (greater than or
equal to the capacity of the original capacity), all of your lost data will be recovered automatically.
For fast read & write altogether with security & capacity.
Set one disk as the parity disk, and all the other data disks.
When one data drive fails, the original data can be recovered by making use of the remaining data and the parity
info. When two drives fail at the same time, all of the data will be unrecoverable.
For fast read & write altogether with security & capacity.
Data and parity info are restored respectively on different disks, and data and its corresponding parity info are on
different drives.
When one of the drives fails, the original data can be recovered by making use of the remaining data and the parity info.
When two drives fail at the same time, all of the data will be unrecoverable.
RAID Modes
RAID 0
(Fast Mode) ON ON ON
ON ON OFF
ON OFF OFF
OFF ON OFF
2
2
3
Total hard drive
capacities
Min. hard drive
capacity
(Drive
number-1) ×
Min. hard drive
capacity
3
(Drive
number-1) ×
Min. hard drive
capacity
RAID 1
(Safe Mode)
RAID 3
RAID 5
DIP
Switch
DIP Switch Status
123 Description
Min. Drive
Number Available
Capacity
09

3 Drive Partitioning and Formatting
Online drive and drive partitioning after switching RAID mode. The formatting may differ
depending on the different operating system, please check your operating system for
reference.
Windows
① Online drive: connect the hard drive to PC/laptop
Go to "This PC" > "Manage" > "Storage" > "Disk Management" and select the correct hard
drive to "Initialize Disk".
② Drive partitioning: create a "New Simple Volume" and set its capacity.
Select the unallocated space and right click "New Simple Volume", then follow the pop-up
windows until the process is completed. Your PC/laptop will be able to read the drive after
formatting.
macOS
Step: "Other" > "Disk Utility" > "Erase", choose the file format "ExFAT", then "Erase" >
"Complete". Your Mac can read the drive after formatting.
If the drive capacity is below 2TB in the current RAID mode, select MBR., otherwise, select GPT.
Note
The default drive format of Windows and Linux is "NTFS", as for macOS, you must choose the
"ExFAT" format.
Note
NCS)Nbtufs!Cppu!Sfdpse*
HQU)HVJE!Qbsujujpo!Ubcmf䯓
Jojujbmj{f!Ejtl
OUGT
Ofx!Tjnqmf!Wpmvnf
10

Linux
Step: "Applications" > "Disks", select the external drive and click "Format Partition"; after
formatting please enter "Mount", then your PC/laptop can read the drive.
V Other Settings
1 Add New Drives
A new hard drive requires RAID mode switching twice, then all hard drives will be formatted. Please
back up all the data in advance.
VI Notes
· For optimal performance, it is recommended that you use the product on the device with USB 3.0
or above ports.
· Please put the product in an environment of stable temperature and humidity to avoid direct
sunlight or any liquid.
· When there is a thunderstorm or an unstable voltage, please power off the product to avoid the
potential damage.
· Please power off the product before you clean it; clean it with a wet wipe, chemicals or spray
cleaner are not allowed.
· Do not drop, crush, hit, or throw the product.
· The product contains small components, please keep out of reach of children.
· Please do not disassemble or repair this product by yourself. Improper disassembly may lead to
electric shock or other potential danger, please contact UGREEN aftersales.
Warning
If there are less than 5 hard drives in the current RAID mode, then you can add new drive(s).
· Power off: press and hold the power button (about 3 seconds) until the power indicator goes off.
· Put the new hard drive in the drive tray and put it into the enclosure.
· Change DIP switch to PM mode.
· Press and hold "RESET" and long press the power button (about 3 seconds) to turn it on; after 15
seconds release "RESET", and then the hard drive indicator flashes white.
· Power off again, and change DIP switch to the original RAID mode.
· Repeat step 4.
· After the hard drive is connected and partitioned, then it's successfully added.
Add a new drive
When using RAID 1/3/5/10/Clone modes, you'll have to replace with a brand new hard drive if one
of your disks fails.
· Press and hold the power button (about 3 seconds) to turn it off.
· Replace the broken disk with a new one.
Tip: capacity of new hard drive ≥ capacity of broken hard drive.
· Press and hold the power button (about 3 seconds) to turn it on.
· When the disk indicator flashes red and white alternately, the new disk starts to restore (back up)
data.
· When the drive indicator turns solid white, the data recovery (backup) is completed.
2 Replace the Broken Drive
11 12

5-Bay 3,5-Zoll-
RAID-Festplattengehäuse
I Hinweis auf Verwendung
1 Vorwort
2 Hinweise
II Anweisungen von Produkt
1 Packungsinhalt
2 Produktübersicht
3 LED Anzeigen
4 Spezifikationen
III Installationsschritte
1 Tablett herausnehmen
2 Festplatteninstallation
2.1 3.5-Zoll Festplatte
2.2 2.5-Zoll Festplatte
3 Einsetzen des Laufwerksfachs wieder in das Gehäuse
4 Stecken die Festplatte in die Steckdose
IV Einstellung und Verbindung von RAID Modus
1 Switch RAID Modus
2 RAID Modus& DIP Switch
3 Partitionieren und Formatieren von Laufwerken
V Andere Einstellungen
1 Neue Festplatte hinzufügen
2 Ersatz einens defekten Laufwerk
VI Hinweise
13
13
13
14
15
15
16
16
16
17
18
19
20
21
22
23
23
InhaltDE
Benutzerhandbuch
Tabla de contenidos
Idiomas:
Otros manuales de Recinto de UGREEN