CONGRATULATIONS
You have just purchased the finest air sweeper produced. Yet, for all of its advanced
engineering, in spite of all the skills that have gone into it - your sweeper is only as good as
its operator.
TYMCO REGENERATIVE AIR SWEEPER SOLD & SERVICED BY:
MODEL DST-4
(Dustless Sweeping Technology)
SND SERIES
NOTE: DO NOT destroy any part of this manual. It contains pertinent information
on parts, operation and maintenance of your TYMCO REGENERATIVE AIR
SWEEPER and truck chassis.
An informed operator will do a better job. Make sure he/she has an opportunity to
study this manual.
© 2018 TYMCO
2019 EDITION
This Operator’s Manual is the property of TYMCO, and is considered proprietary.
It may not be reproduced by photocopying or otherwise without
the express written permission of TYMCO.
Violators will be prosecuted to the full extent of the law.


INTRODUCTION
To insure proper understanding of operation, cleaning and maintenance of your TYMCO
REGENERATIVEAIRSWEEPER,itisnecessarythatthisOperator’sManualandtheService
& Parts Manual be read and studied from cover to cover by the operator.Afull understanding
of this equipment will help the operator achieve the results expected of this machine.
Though, seemingly, a very simple machine, the TYMCO REGENERATIVE AIR SWEEPER
utilizes air instead of conventional rotary brushes, brooms and conveyers. Aerodynamic
problems that arise in the REGENERATIVE AIR SWEEPER are not as easily identified and,
therefore, necessitates a complete understanding of the machine.
The TYMCO REGENERATIVE AIR SWEEPER is designed to maintain cleaner surfaces at
higher speeds and at lower cost. The performance capability of this truly modern machine is
only limited by the initiative of those responsible for its operation. There are many different
conditions found in sweeping, and we believe it impossible to answer all of the problems
here. Most important in the operation and maintenance of this machine, is that it should be
KEPT CLEAN.
TheOperator’sManual includes the necessary checks, operating and adjustment procedures
neededbytheoperatorfromdaytoday.Foranyspecificadjustment,problem,ormaintenance
checks not explained in this manual, please refer to the Service & Parts Manual.
KEEP OUR STREAMS AND RIVERS CLEAN
PICK IT UP WITH YOUR TYMCO


TIL-099 / November 29, 2017
Complete Sweeper
Inspection
Check Auxiliary Engine Oil and
Coolant
Check for Seal Leaks
Check Warning And Work Lights
Inspect Pick-up Head
Check Gutter Broom
Adjust Mirrors
Fill Fuel Tank
Fill DEF Tank(s) (if equipped)
Fill Water System
Check Dustless Box, Pre-cleaner,
and Scavenge Hose
Sweeper Start-up
1. Lower Pick-Up Head using
Auxiliary Hydraulics
2. Start Rear Engine (Must be in
idle)
3. Turn on Warning Lights
4. Turn on DC System and Air
Purge System
5. Pull Sweeper Forward to Tuck
Pick up Head Curtains.
6. Turn on Water System
7. Throttle upAuxiliary Engine
RPM to desired levels. Wait
45 seconds before starting
sweeping.
8. Lower Gutter Broom (s)
9. Begin Sweeping
10. DO NOT BACK UPWITH
PICK-UP HEAD DOWN.
Throttle down, pick up head then
back up. (Reverse Pick-Up Head
Chains – allow you to back up
with the head down.)
Sweeper Shut Down
1. Lower Auxiliary Engine RPM to
idle speed (1100 RPM for Model
DST-4 and 1000 for Model DST-
6) and turn off Purge System
2. Raise Gutter Brooms (Must hold
switch in the up position to fully
retract gutter broom)
3. Turn offAuxiliary Engine
4. Turn on Auxiliary Engine Switch,
DO NOT start.
5.Using Auxiliary Hydrualic
System, raise Pick-Up Head.
6. Turn off Water System if on
7. Turn off Warning Lights
8. Turn offAuxiliary Engine Switch
Clean Out Procedures
(DAILY)
Clean Hopper Screens
Clean out Hopper
Clean out Dust Separator
Clean under Pick-up Head
Clean around gutter brooms
Clean Exterior of Sweeper and
Chassis
Clean off Radiators
Dustless Operations
(Shutdown)
Idle down auxiliary engine.
Turn on purge system and
listen for air guns to discharge
approximately every 17 seconds.
Allow purge system to operate for
approximately 5 minutes.
Check pressure relief port for
proper function.
Drain any accumulated moisture
from the water/air filter located at
the top of the filter assembly box.
Open pre-cleaner door and
CAREFULLY remove pre-cleaner
assembly. Shake off any dust
and if necessary, use “shop air”
to blow out any accumulation
of dust from pre-filter openings
and wash thoroughly. Must
be completely dry before next
sweeping day.
NOTE: Clean scavenge bin and
scavenge hose daily with water.
With fi
lter side door open, look
at the 4 Torit-Tex® filters, if
excessive amount of dust is
present, reassemble all hoses
and insure that all doors are
closed and latched and attach
shop air to the air hose fitting
located on left bottom of dust
box below air manifold tank.
Filters purge system can be run
without auxiliary engine running.
Auxiliary engine can also be used
to operate purge system after
system has been fully charged
(100 psi) if desired.
Always insure that on/off switch
is in the OFF position and purge
all air from the air tank before
beginning any service work in
dustless box assembly.
Check all water spray nozzles
daily to insure they are spraying
properly. (Never operate
gutter brooms without dust
control system engaged and all
water toggle switches in “on”
position.)
Parking Procedures
Leave Hopper Door and
Inspection Door(s) Open
Operating Procedures Guidelines
Model DST-6 & DST-4

TIL-064 / November 14, 2018
TYMCO REGENERATIVE AIR SWEEPER INSPECTION
AND REPETITIVE TASK SCHEDULE
Inspect
Gutter broom(s) for impact damage/
wear Daily
Pick-up head blast orifice for lodged
foreign material/adjustment Daily
Pick-up head skid plates for wear/
impact damage Daily
Pick-up head curtains for wear/
damage Daily
Hydraulic system for plumbing or
component leakage Daily
All hopper and transition seals for
wear/damage Daily
Hopper screen for damage Daily
Tires Daily
Hydraulic oil return line filter restriction Daily
Water pump oil level Daily
(If applicable)
Water filler hose filter screen Daily
(If applicable)
Water pump suction hose pre-filter Daily
(If applicable)
Dust separator liner for wear/damage Daily
(If applicable)
Dust separator door closed before
operating Daily
(If applicable)
Engine air intake filter restriction
indicators Daily
(If applicable)
Pick-up head turning vanes for wear/
foreign material Weekly
Blower belt tension
100 Hours
(Minimum)
(If applicable)
Pressure and suction hoses for wear 100 Hours
Blower wheel for wear/damage 100 Hours
Accessible areas of blower housing
liner for wear/damage 100 Hours
Blower lip for wear/damage 100 Hours
Perform
Cleaning of gutter broom torque motor
shaft area Daily
Check of hydraulic tank fluid level Daily
Draining water tank Daily
Cleaning of hopper and dust separator Daily
Wash down of engine radiator(s) Daily
Functional test sweeper lights Daily
Functional test truck brakes Daily
Functional test truck lights Daily
Check of truck fluid level Daily
Check of auxiliary engine fluid level Daily
(If applicable)
Rotation pressure and suction hoses
1/4 turn 100 Hours
Grease PTO driveshaft 100 Hours
(If applicable)
Change of water pump oil 150 Hours
(If applicable)
Change of hydraulic oil return line filter 1000 Hours
or when
Indicated
Change of hydraulic system oil 2000 Hours or
by oil analysis
Adjustment of gutter brooms As required
Cleaning of spray nozzle tips and
screens As required

NEVER REACH INTO BLOWER HOUSING FOR ANY REASON!
!
ITEM DESCRIPTION RECOMMENDED SERVICE
1. Blower Bearings Grease once a week or every 25 hours of operation.
2. Blower Power Band Re-tension after initial 10 hours; then check every 100 hours.
3. Blower Wheel Inspect monthly for wear. DO NOT REACH INTO BLOWER HOUSING
FOR ANY REASON!
4. Gutter Broom / Wafer Check DAILY for string, cassette tape, etc on motor shaft. Re-tension
spring when new wafers are installed.
5. Hydraulic Reservoir Change oil every 2000 hours or by oil analysis recommendation. Check
oil level DAILY.
6. Hydraulic Oil Filter Change every 1000 hours or as indicated by restriction indicator.
7. Aux. Engine Air Cleaner Replace when restriction indicator shows red.
8. Auxiliary Engine Change oil every 100 hours, for additional service refer to engine man-
ual. Check oil level DAILY.
9. Console Fuse Panel Always replace fuse with identical amp rating.
10. Both Engine Radiators Check DAILY. CAUTION - Check only when cold.
11. Truck Air Cleaner Service every 25 hours or when restriction gauge indicates.
12. Transmission Change oil & filter every 15,000 miles or once a year.
13. Water Tank Drain tank DAILY.
14. Centrifugal Separator Wash out DAILY! Cleanout door provided on engine side.
15. Separator Seal Clean seal DAILY. Hopper must be airtight and fit snuggly against seal
when lowered.
16. Skimmer Hood Inspect DAILY! Skimmer hood must swing freely when hopper is raised
in order to clean itself of debris.
17. Hopper Screen Wash DAILY to prevent air blockage.
18. Hopper Wash out at end of each shift to prevent rusting.
19. Dump Door Seal Inspect DAILY; replace if damaged.
20. Hopper Pivot Hinge Grease every 25 hours of operation or once a week. CAUTION: Hop-
per must be raised in order to grease hinge. Always Install Pin in Lower
Safety Strut!
21. Truck Tires Check DAILY for flats and correct air pressure.
22. Spring Tension Check skid plates weekly for wear; adjust spring tension as required.
23. Pick-Up Head Curtains Inspect DAILY; replace when worn out .
24. Drag Link Inspect DAILY for condition
25. Truck Engine Change oil and filter every 100 hours or 3000 miles of operation.