Tsun TSOL-B100E-S Manual de usuario

- 1 -
TSOL-B100E-S

- 1 -
Content
CHAPTER 1 SAFETY PRECAUTIONS .................. - 2 -
1.1 SAFETY INSTRUCTIONS..................................... - 2-
1.2 EXPLANATIONS OF SYMBOLS ................................ - 3-
1.3 EMERGENCY SITUATION.................................... - 4-
CHAPTER 2 PRODUCT INTRODUCTION ............... - 5 -
2.1APPLICATION SCOPE OF PRODUCTS........................... - 5-
2.2 SPECIFICATION FOR PRODUCT MODEL ........................ - 5-
2.3 DATASHEET.............................................. - 6-
CHAPTER 3 INSTRUCTIONS FOR INSTALLATION ...... - 7 -
3.1 ITEMS IN THE PACKAGE .................................... - 7-
3.2 INSTALLATION POSITION ................................... - 8-
3.3 MOUNTING PROCEDURE .................................. - 10 -
CHAPTER 4 ELECTRICALCONNECTION ............. - 14 -
4.1 SPECIFICATIONS FOR ELECTRICAL INTERFACE ................ - 14 -
4.2 SLAVE CONNECTION ...................................... - 15 -
4.3 COMMUNICATION INTERFACE .............................. - 17 -
4.4 INSTALLTHE RIGHT COVER ................................ - 18 -
CHAPTER 5 DEBUGGING INSTRUCTIONS ............ - 19 -
6.1TRANSPORTATION........................................ - 19 -
6.2 STORAGE............................................... - 19 -
CHAPTER 7 CONTACT US........................... - 20 -

- 2 -
Chapter 1 Safety Precautions
The User Manual describes system configuration and detailed procedures for
installation, operation and maintenance of TSOL-B100E-S Series Inverter Battery.
However, this manual does not include any information about inverters that the
battery may be applied to. Please read the User Manual before using this product.
1.1 Safety Instructions
DANGER
•Do not expose the battery to temperatures in excess of 45°C.
•Do not subject the battery to any strong force.
•Do not place the battery near a heat source, such as direct sunlight, a fireplace.
•Keep inflammable and explosive dangerous items or flames away from the battery.
• Do not soak the battery in water or expose it to moisture or liquids.
WARNING
•Only qualified personnel who has full knowledge of local safety regulations and local
standards on battery can install, maintain, retrieve and process this product.
•TSUNESS shall not be liable for any loss or warranty claims arising from any unauthorized
change of product which may cause fatal injury to the operator, third party or equipment
performance.
•For personal and property safety, do not short-circuit the positive (+) and negative (-)
electrode terminals.
CAUTION
•Do not modify or change any components in the battery.
•Risk of damage due to improper modification
NOTICE
•During installation of the battery , circuit breaker must be disconnected from the battery
pack wiring.
•The battery can only be used as a set with TSUNESS ACU series AC Coupled Unit,
otherwise it cannot be used normally.

- 3 -
1.2 Explanations of Symbols
Symbol
Description
Dangerous electrical voltage
The device is directly connected to public grid, thus all work to
the battery shall only be carried out by qualified personnel.
No open flames
Do not place or install near flammable or explosive materials.
Danger of hot surface
The components inside the device will release a lot of heat
during operation. Do not touch metal plate housing of the
inverter during operating.
Attention
Install the product out of reach of children
An error occurred
Read the usage manual to troubleshoot problems
This device SHALL NOT be disposed of in residential waste
Please go to Chapter six “Battery maintenance” for proper
treatment.
CE Mark
The device is in compliance with Low Voltage Detective and
Electromagnetic Compatibility.
Recyclable

- 4 -
1.3 Emergency situation
Despite of its careful and professional protection design against any hazard results,
damage of the battery may still occur. If a small amount of battery electrolyte is
released due to a serious damage of the outer casing; or if the battery explodes due
to not being treated timely after a fire breaks out nearby, and leaks out poisonous
gases such as carbon monoxide, carbon dioxide and etc., the following actions are
recommended:
1)Eye contact: Rinse eyes with a large amount of running water and seek
medical advice
2)Contact with skin: Wash the contacted area with soap thoroughly and seek
medical advice
3)Inhalation: If you feel discomfort, dizziness or vomiting, seek medical
advice immediately.
4)Use Heptafluoropropane (FM-200) or carbon dioxide (CO2) fire
extinguisher for battery fire, If a fire breaks out in the place where the battery pack
is installed
5)Use an ABC fire extinguisher, if the fire is not caused by battery and not
spread to it yet.
Warning
•If a fire has just occurred, try to disconnect the battery circuit breaker and cut
off the power supply first, but only if you can do so without endangering
yourself.
•If the battery is on fire, do not attempt to extinguish the fire and evacuate the
crowd immediately.

- 5 -
Chapter 2 Product Introduction
2.1 Application Scope of Products
The battery is applied to domestic photovoltaic storage system. The battery is built
eternally with a battery management system (BMS), which is used to ensure
efficiency of the battery and to avoid phenomena of overcharge or over-discharge.
The battery employs modular design for easy installation and wiring, and can be
used by up to 3 parallel devices. Battery is also called slave machine in the
following text.
Figure 2.1 outside overview
2.2 Specification for Product Model
TSOL –B100E –S
①②③
①TSOL of the brand.
②Energy capacity of battery XXAh,for instance, 100 means 100Ah.
③S means standard voltage of 48V.

- 6 -
2.3 Datasheet
TSOL-B100E-S
Type
TSOL-B100E-S
Electrical Characteristics
Total Energy Capacity[Wh]
5120
Usable Capacity [Wh]
4600
Rated Voltage [V]
51.2
Voltage range [V]
42~58.4
Depth Of Discharge[DOD]
≤90%
Cycle Life
≥4000
Max.Charge Current [A]
60
Max.Discharge Current [A]
60
Physical Parameters
Battery Type
Lithium ion
Communication
CAN
Operating Temperature Range
0°C~50°C
Cooling Method
Natural Convection
Ambient Humidity
0-95% Non-condensing
Ingress Protection
IP65
Dimensions[H*W*D][mm]
410*650*186
Weight [kg]
50
Standard Warranty [Year]
5(Battery 4000 Cycle)
Applicable Standard
UN38.3、IEC62619

- 7 -
Chapter 3 Instructions for installation
3.1 Items in the package
Battery pack
Wall bracket
mounting bolts set *6
Cables
Ethernet cable&RJ45 plug
User Manual

- 8 -
3.2 Installation Position
3.2.1 The battery size shown as follows
186
410
650
Figure 3.1 TSOL-B100E-S External view and dimension
3.2.2 Installation Position
This device is cooled by natural convention and suggests an indoor installation or
an installation under a sheltered place to prevent the battery from exposure to
direct sun, rain and snow erosion.
Figure 3.2 Mounting Method

- 9 -
3.2.3 Mounting Method
A vertical mounting is recommended and the battery accepts backwards by
Max.15°. Never mount the battery horizontally or upside down.
√ √
× × ×
Figure 3.3 Mounting method
Please make sure the battery pack is at all times exposed to the ambient air. Poor
air circulation will affect the performance of internal electronic components and
shorten the service life of inverter.
50CM
50CM 50CM
0CM 0CM
Figure 3.4 Installation position
Tabla de contenidos