5
AUTOMATIC CODE LEARNING (opon #1)
Note: Code all the sensors to the display BEFORE screwing
them onto the re valve stem unless otherwise noted.
1. Push and hold the “SET” buon unl it beeps. You are
now in the programming mode. The “HI PRESSURE SET”
parameter will blink at the boom of the screen. Push
the (+) buon and scroll through the parameters unl
“LEARN ID” appears.
2. Quickly press and release the “SET” buon. The rst
re on the display will blink. If you want to program a
dierent re, press the (+) buon to move to the correct
re. Push the “SET” buon again and “FFF FFF” will ash.
Put the sensor for that re posion next to the display
and press the “GO” buon. The display will capture
the sensor code and show it on the screen. Again, push
and release the “SET” buon to save the code to that
posion. If a double beep is heard, try pressing the “GO”
buon again. When coded correctly, a single beep will be
heard and a six (6) digit code will be shown.
3. Use the (+) buon to move to the next re posion you
want to program. Again, press the “SET” buon and
“FFF FFF” will blink. Put the sensor for that re posion
next to the display and press the “GO” buon to capture
the sensor code. Press “SET” again to save.
4. When you are nished programming all of your sensors,
press the “BACK” buon to return to the parameter
at the boom of the screen. Use the (+) or (-) buons
to scroll to another parameter, if necessary. If nished
programming, press the “BACK” buon again to go to
the Main Screen. (Your sensors will begin reading “0”
pressure and will alarm. Press the (+) buon to silence
the alarm while you connue your set-up).
TST-Doc-507 WSD Manual-(A)