Trolex TX6351 Manual de usuario



TX6351 • TX6352 User Manual
P5536.1600 rev A 3
TX6351 • TX6352 Sentro 1 Universal Gas Detector
Contents
1. Product Overview 4
1.1 Operating Features 4
1.2 Application 5
1.3 Product Options 5
1.4 Dimensions 6
1.5 Technical Information 7
1.6 Electrical Details 9
1.7 Sentro eModules 11
2. Certification 18
3. Installation 20
3.1 Safety Precautions 20
3.2 Tools and Test
Equipment Required 21
3.3 Siting Recommendations 21
3.4 Connections 23
3.4.1 0.4 to 2 V Analogue
Output Signal 23
3.4.2 4 to 20 mA Analogue
Output Signal 24
3.4.3 5 to 15 Hz Output Signal 25
3.4.4 Contact Output Signal 25
3.4.5 RS485 Data Output Signal 26
3.5 Connecting in Hazardous
Areas 27
4. Setup and Calibration 28
4.1 Controls and Indicators 28
4.2 Main Display 30
4.3 Security Code Access 31
4.4 Main Menu 32
4.4.1 Calibrate 33
4.4.2 Sentro 1 Setup 36
4.4.3 Output Setup 38
4.4.4 Modbus 41
4.4.5 Module Setup 41
4.4.6 Support 44
5. Diagnostics and
Maintenance 45
5.1 Diagnostic Messages 45
5.2 Maintenance 46
5.3 Maintenance and
Calibration Log 49
5.4 Disposal 50
Disclaimers 51
Trademarks 51
Contact Details 51
Document History 51
www.trolex.com

4 P5536.1600 rev A
1. Product Overview
TX6351 3/4 wire device with separate output signal and power lines.
Can be used with any Sentro eModule
TX6352 2-wire line powered 4 to 20 mA output signal.
Can ONLY be used with electrochemical Sentro eModules
1.1 Operating Features
• Fixed sensor for detection of Toxic Gases and Flammable Gases
• Exclusive pre-calibrated plug-in gas sensing modules for many types of gas and
climatic conditions
• LCD readout and visual LED alarm indicators
• Choice of supply voltage and output signal format
• Heavy duty housing to IP65, EMC compliant
• STEL and TWA monitoring for selected gases
www.trolex.com

TX6351 • TX6352 User Manual
P5536.1600 rev A 5
1.2 Application
Fixed point gas detection for safety monitoring in hazardous areas and general
purpose applications.
Underground Mining andTunnelling
Ex ia I Ma
TX6351.01
TX6352.01
Supply Voltage: 12 V dc from an
approved power source
Type of protection:
Intrinsically safe. Ex ia
Category: I M1
General Purpose
TX6351.03
TX6352.03
Supply Voltage: 24 V dc
1.3 Product Options
4-wire connection Mining Ex ia General Purpose
0.4 to 2 V output TX6351.01.11 -
4 to 20 mA output TX6351.01.12 TX6351.03.12
5 to 15 Hz output TX6351.01.13 -
Contact output TX6351.01.14 TX6351.03.14
RS485 output TX6351.01.15 TX6351.03.15
*2-wire line powered Mining Ex ia General Purpose
4 to 20 mA output TX6352.01.12 TX6352.03.12
*For use with Toxic Gas Sentro eModules only
www.trolex.com

6 P5536.1600 rev A
1.4 Dimensions
www.trolex.com

TX6351 • TX6352 User Manual
P5536.1600 rev A 7
1.5 Technical Information
Ambient temperature limits -20 to +40°C
Storage temperature -20 to +60°C
Ambient pressure 800 to 1100 mbar
Humidity 90% non-condensing
Protection classification Dust and waterproof to IP65. Gas Port: IP54.
Housing material Reinforced polymer
Nett weight 150 g
Cable entries 2 x M20
Electrical connections 4 mm barrier/clamp terminals
Conductors A maximum of two per terminal
Conductor size A maximum of 2.5 mm²
Terminal torque 2.4 Nm maximum
Information display 128 x 64 dot graphic backlit LCD
Vibration limits Vibration limits (EN 60079-29-1):
• 10 to 30 Hz - 1.00 mm total excursion
• 31 to 150 Hz - 19.6 m/s2acceleration peak
Impact limits 20 joules (housing)
Calibration and setup Digitally controlled ZERO and SPAN pushbutton
setting
Signal fix The analogue output signal of the sensor is fixed
during calibration to prevent false alarms from
being initiated
Fault indication Under range signal transmitted and fault display
for:
• Loss of communications from the sensing
module
• Sensing module absent for more than 10
seconds
• Sensor over-range protect
Key coding Coding stops prevent insertion of a non-valid
sensing module.
www.trolex.com

8 P5536.1600 rev A
Alarms Programmable GENERAL alarms and HIGH
alarms with an LED indicator.
The two adjustable alarm setpoints are preset
during manufacture to default values appropriate
to the type of sensor, determined by the sensing
module being used.
STEL andTWA Automatic calibration of STEL and TWA limits to
EH40 standards.
STEL: Exposure over 15-minute successive
periods
TWA: Exposure over a continuous rolling 8-hour
period
Output signals 0.4 to 2 V
4 to 20 mA
5 to 15 Hz
Dual contacts
RS485 Modbus datacomms
www.trolex.com

TX6351 • TX6352 User Manual
P5536.1600 rev A 9
1.6 Electrical Details
General Purpose
TX6351 3/4 wire. Remote powered
4 to 20 mA analogue output
Supply voltage: 18 to 28 V
Max. line load: 500 R at 24 V
Type of sensor: Toxic Flammable Infrared
Supply current: 40 mA 40 mA 60 mA
TX6351 3/4 wire. Remote powered
Dual output contacts
Supply voltage: 20 to 28 V
Type of sensor: Toxic Flammable Infrared
Supply current: 35 mA 45 mA 60 mA
TX6351 3/4 wire. Remote powered
RS485 datacomms output
Supply voltage: 14 to 28 V
Line: Modbus protocol
Type of sensor: Toxic Flammable Infrared
Supply current: 40 mA 40 mA 60 mA
TX6352 2 wire. Line powered
4 to 20 mA analogue output
Supply voltage: 18 to 28 V
Max. Line Load: 300 R
Type of Sensor: Toxic only
www.trolex.com

10 P5536.1600 rev A
Mining and Tunnelling
TX6351 3/4 wire. Remote powered
4 to 20 mA
Supply voltage: 10 to 14 V
Max. line load: 220 R maximum @ 12 V dc
Type of sensor: Toxic Flammable Infrared
Supply current @ 12 V: 48 mA 70 mA 91 mA
TX6351 3/4 wire. Remote powered
Dual output contacts
Supply voltage: 10 to 14 V
Type of sensor: Toxic Flammable Infrared
Supply current @ 12 V: 60 mA 85 mA 105 mA
TX6351 3/4 wire. Remote powered
RS485 datacomms output
Supply voltage: 10 to 14 V
Line: Modbus protocol
Type of sensor: Toxic Flammable Infrared
Supply current @ 12 V: 25 mA 60 mA 80 mA
TX6351 3/4 wire. Remote powered
0.4 to 2 V analogue output
Supply voltage: 10 to 14 V
Min. line load: 10 KR
Type of sensor: Toxic Flammable Infrared
Supply current @ 12 V: 20 mA 60 mA 80 mA
TX6351 3/4 wire. Remote powered
5 to 15 Hz analogue output
Supply voltage: 10 to 14 V
Max. line load: Opto isolated to 2 mA maximum
Type of sensor: Toxic Flammable Infrared
Supply current @ 12 V: 20 mA 60 mA 80 mA