- 7 -
INSTALLATION
FLEXIBLE COUPLING ALIGNMENT
There are two types of misalignment encountered with flexible
couplings: angular misalignment and parallel misalignment. To
check for angular misalignment and parallel misalignment, insert
a taper gauge or feeler gauge at four places located 90° apart
around the coupling as shown in figure three. The coupling
halves are properly aligned when the measurements are the
same at all check points.
To check parallel misalignment, place a straight edge across the
coupling half rims at the top, bottom and both sides, making sure
that the straight edge is parallel to the motor and pump shafts.
See figure four. The coupling are properly aligned when the
straight edge rests evenly on the coupling rims at all check
points.
Correct alignment is obtained by use of shims under the motor
mounting feet. See Figure Five. Adjustments made in one
direction may effect alignment in another direction. Therefore
several checks of both angular and parallel alignment should be
made.
GROUTING
When the alignment procedures have been completed, the
foundation bolts should be evenly tightened but not too firmly.
The unit can then be grouted to the foundation.
A form should be constructed around the base plate to hold the
grout. The base plate should be completely filled with grout, and
it may be desirable to grout the support blocks or wedges in
place. Do not tighten the foundation bolts until the grout has
hardened, usually 48 to 72 hours after pouring.
FINAL ALIGNMENT
After the grout has hardened, the foundation bolts should be
firmly tightened, the suction and discharge piping installed, and a
final alignment check made. Be sure the suction and discharge
piping is properly supported to avoid any strain on the pump
casing.
Note:
Check the direction of motor shaft rotation to make sure
it is the same as the arrow on the pump before
connecting the flexible coupling and starting the pump.
Connect the flexible coupling, and with the pump properly
primed, start the pump and operate it until temperatures are
stabilized. The unit should then be shut down and the alignment
immediately rechecked.
Straight Edge
Flexible Coupling
Taper
Gauge
Figure Four
Straight Edge
Flexible Coupling
Figure Five
Straight Edge
Flexible Coupling
Figure Three