This Manual is prepared for the use of qualified personnel. It should not be used by those not properly
qualified. Before proceeding with any work, you should read, in its entirety, the procedure you wish to
perform in order to determine if you have the necessary tools and skill required to perform the procedure.
Procedures for which you do not have the necessary tools and/or skill should not be performed.
TRAULSEN RBC50, RBC100 & RBC200
BLAST CHILLERS
service guide
basic

Table of Contents
1TRAULSEN RBC50, RBC100 & RBC200 BLAST CHILLER BASIC SERVICE GUIDE
One button start
means safe food every cycle!
Page
Programming The Control....................................................... 2
General Troubleshooting......................................................... 3-4
Replacing The Control Board.................................................. 5
Replacing Either Printer...........................................................6
Repairing Moisture Damage....................................................7
Verifying Control Version......................................................... 8
Locating Refrigerant Leaks..................................................... 9
Resetting The Control..............................................................10
Parts List..................................................................................11
Interior air
temperature
Press to chill BY
PRODUCT
Press to quickly
start a Chill Cycle
Press to access
additional menus
Press to chill
BY TEMP
Press to start
a chill cycle
BY TIME
Time
Main Menu
LEGEND:
Push button to left or right of any feature marked by or to select that feature.
Push button to left or right of any feature marked by or to change value of that feature.
↓↓
↓↓
↓↑↑
↑↑
↑

1. From the Main Menu Screen press MORE, then
SETUP. The display will change to the Password
Screen.
2. From the Select Supervisor Screen, use the UP and
DOWN arrows to the left and right of PASSWORD to
select 57. Press ENTER. The display will change to
the Set Up Screen.
3. From the Set Up Screen press the button to the right
of SYSPAR.
4. The ITEM list will display date and time elements in
the following order.
a) MONTH (JANUARY – DECEMBER)
b) DATE (1 – 311)
c) YEAR (2003 – 2079)
d) DAY OF WEEK (SUNDAY – SATURDAY)
e) HOUR (0 – 23)
f) MINUTE (0 – 59)
g) DLS - Daylight Savings TIme (ENABLED – DISABLED)
e) LOW ALARM (-30 – 0)
5. Press the button to the left of ITEM to select between
the different items. Adjust the VALUE for each ITEM
using the UP and DOWN buttons.
6. Press ENTER to return to the MAIN MENU.
2
Programming the Control
How to Set Correct Date & Time
SYS PAR: SET CLOCK
ITEM:MONTH
VALUE:APRIL
CANCEL ENTER
SYS PAR: SET CLOCK
ITEM:MONTH
VALUE:APRIL
CANCEL ENTER
MAIN MENU AIR 35°F
BY TEMP BY PROD
BY TIME
08:05:01 MORE
MAIN MENU 08:06:01
HOLD PROD PRINT
DEFROST SETUP
BACK
SYS PAR: SET CLOCK
ITEM:YEAR
VALUE:04/14/10
CANCEL ENTER

General Troubleshooting
3TRAULSEN RBC50, RBC100 & RBC200 BLAST CHILLER BASIC SERVICE GUIDE
PROBLEM: Extended or unsafe chill times.
a. Is the door closed properly? If not close door.
b. Excessive product load. Reduce product loaded.
c. Has pan been covered with a lid, plastic wrap or foil, and is this not in direct
contact with the product? Cover product correctly.
d. Product too large or loaded too deep in pans. Reduce product size or depth.
e. Too much ice on evaporator coil. Cover product (if not already) and/or run manual
defrost prior to next chill cycle.
f. Dirty condenser coil. Clean condenser.
g. Evaporator coil iced (below). Press MORE - DEFROST to start a manual defrost.
h. Refrigeration system issue. Contact service.
PROBLEM: Upon cycle start probe temps appear cooler than expected.
a. Product temp within cooked batches vary. Verify actual product temp with
thermometer (probed piece).
b. Probe placed incorrectly. Reset probe placement.
c. Very small product (potsticker). Use chill by time.
d. Product held too long at room temp prior to chilling. Verify actual product temp
with thermometer (probed piece).
PROBLEM: Previously observed/expected high product temps differ from those
shown on cycle data printout.
a. See above for possible causes.
b. Bad food probe. Replace probe.
c. Batch started incorrectly. Start chill cycle according to owner’s manual
instructions.
d. Moisture damage to the control. Replace control.
PROBLEM: Occasional defrost sensor warning.
Coil did not defrost to target temp, usually the result of too much ice build-up from either:
a. A very long chill cycle/large product load.
b. Starting a new cycle close to when the chiller would need to automatically defrost.
c. Product releasing a lot of moisture during chilling.
d. A combination of 2 or more of the above.
PROBLEM: No data available for printing or later than actual start time or start
temperature data appears on cycle/data printouts for a given probe.
a. Product (probe) added to active chill cycle incorrectly (i.e. failure to press
ADD/REMOVE and/or CONTINUE).
PROBLEM: Product freezing.
a. Chilled product not removed and additional product added. Remove when DONE.
b. Chill cycle By Time set for too long. Reduce chill time.
c. High water content product (ex. soup). Use SOFTCHILL.

4
General Troubleshooting (cont’d.)
PROBLEM: Incorrect date/time shown on display and/or printouts.
a. Incorrect time and/or date setting. Correct date and/or time settings.
b. Control issue. Replace control.
PROBLEM: Defrost appears to have occured before chill cycle completion.
Defrost will not occur until all food probes have reached target temp (DONE).
a. Chiller completed chill cycle for all probes. Retrieve cycle data after defrost.
PROBLEM: Chiller will not print or display reads MEDIA ERROR.
a. Check to insure paper is properly loaded, remove any paper jam.
b. If upon completing above the control continues to display MEDIA ERROR,
cycle power OFF, then ON again (req’d for control versions prior to 2.0).
c. Printer requires replacement.
PROBLEM: Evaporator Coil Icing.
a. Hot product placed in chiller for long time without starting a chill cycle.
b. Uncovered liquid product, cover product with plastic wrap.
c. Refrigerant leak. Call service.
d. Failed coil sensor. Call service.
e. Other system problem. Call service.
PROBLEM: Continuous defrost sensor warning.
a. Failed defrost heater. Call service.
b. Failed defrost sensor. Call service.
PROBLEM: No data available for printing or later than actual start time or start
temperature data appears on cycle/data printouts for a given probe.
a. Product (probe) added to active chill cycle incorrectly (i.e. failure to press
ADD/REMOVE and/or CONTINUE).
PROBLEM: Probe(s) display -99 temperature.
a. Check the probe plug connection. Properly secure probe connection.
b. Food probe failure. Damaged or defective food probe. Replace food probe.
PROBLEM: Food probe in use does not display product temperature.
a. Check the probe plug connection. Properly secure probe connection.
PROBLEM: Power loss notification.
a. Power was lost to the Blast Chill unit. If product was inside the unit see the
printout to determine if product temperature was compromised. The printout
will show the temperature before and after the interruption.
PROBLEM: Cannot program a new batch.
a. Unit may be in a defrost cycle. Wait until defrost cycle completes.

1. Remove thumb screws & control cover (see fig. 1).
2. Remove Five (5) #2 Phillips head screws (see fig. 2).
3. Disconnect ten (10) electrical connections (see fig. 3).
4. Re-assemble in reverse order.
5. Restore power.
6. If previously authorized by Traulsen, insert original control in pre addressed mailer
and return to Traulsen.
Replacing The Control Board
5TRAULSEN RBC50, RBC100 & RBC200 BLAST CHILLER BASIC SERVICE GUIDE
WARNING
DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND
FOLLOW PROPER LOCKOUT/TAGOUT PROCEDURES.
Fig. 1
Fig. 2
Fig. 3

6
Replacing Either Printer
WARNING
DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND
FOLLOW PROPER LOCKOUT/TAGOUT PROCEDURES.
1. Remove four (4) thumb screws & control cover (see fig. 1).
2. Remove paper or labels and spindle
3. Remove two (2) #2 Phillips head screws securing the
printer (see fig. 2).
4. Disconnect two (2) electrical connections (see fig. 3).
Discard old printer.
5. Re-assemble in reverse order using a new printer.
6. Restore power.
Fig. 2
Fig. 3
Fig. 1
Printer Details
LEGEND
1) Printer Power Port-Red Harness
2) Printer Data Port-White Harness
3) Cutting Wheel Cartridge
4) Paper Folded To Point For Easy
Feed
5) Feed Roller
6) Feed Roller Tension Arm
7) Thermal Paper or Label
Stock
NOTE:
Order printer supplies from Traulsen or your local Hobart Sales/Service Office. Record
Paper: p/n 400-60003-00, Labels: p/n 400-60004-00.
NOTE:
Record paper is also available from: Office Depot (item# 302-224) or Staples (item# PMF-5233).

1. Access the control boardand/or printers by
removing four (4) thumb screws & control cover
(see fig. 1).
2. Remove the control board (see page 5) and/or
printers (see page 5 and 6) which might be
effected moisture or grease.
3. Spray any electrical contacts (see fig. 2) which
exhibit evidence of grease or water damage
(indicated by a green color, see inset) with a
commercial contact cleaner. This will dislodge
the contamination.
5. Wipe away any debris or excess contamination
using a cotton swab. Allow adequate time to dry.
6. Reassemble the control in reverse order.
Repairing Moisture Damage
7TRAULSEN RBC50, RBC100 & RBC200 BLAST CHILLER BASIC SERVICE GUIDE
Fig. 1
Fig. 2
WARNING
DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND
FOLLOW PROPER LOCKOUT/TAGOUT PROCEDURES.

8
Verifying The Control Version
1. On the main menu display press MORE.
2. Press SETUP. The SELECT SUPERVISOR screen
will be displayed.
3. Enter PASSWORD/PIN 85.
4. Press the top left, top right, and bottom right buttons
at the same time.
5. The control version will appear on the display.
SELECT SUPERVISOR:
↓↓
↓↓
↓PRESET SUPERVISOR↑↑
↑↑
↑
↓↓
↓↓
↓PASSWORD (PIN): 00↑↑
↑↑
↑
CANCEL ENTER
SELECT SUPERVISOR:
↓↓
↓↓
↓TIM SMITH ↑↑
↑↑
↑
↓↓
↓↓
↓PASSWORD (PIN): 85↑↑
↑↑
↑
CANCEL ENTER
MAIN MENU AIR 35°F
BY TEMP BY PROD
BY TIME
08:05:01 MORE
MAIN MENU 08:06:01
HOLD PROD PRINT
DEFROST SETUP
BACK
FACTORY SETTINGS
VERSION 2.0
S/N:T00000A00
RESET NEXT

Locating Refrigerant Leaks
9TRAULSEN RBC50, RBC100 & RBC200 BLAST CHILLER BASIC SERVICE GUIDE
1. Access the refrigeration system, recovering remaining refrigerant per EPA guidelines.
2. Connect the low (BLUE) side of gauge manifold to schrader valve..
3. Connect refrigerant bottle to center of gauge manifold and open valve on bottle to purge
hose to manifold gauge.
4. Open valve on low side of gauge manifold and charge system with a small amount of R-22
refrigerant (1-2 ounces).
5. Close bottle valve and gauge valve.
6. Disconnect refrigerant bottle and connect nitrogen bottle.
7. Set output valve on nitrogen bottle to equal the appropriate pressure, for the design rated
refrigerant at 100 degrees F on the P/T chart (see system data plate for design
refrigerant).
8. Open nitrogen bottle and gauge manifold valve (low side) and allow pressure to equalize.
9. Shut off both valves and disconnect the nitrogen bottle.
10.Using a leak detector, check for leaks at all tubing connections.
a) If any leaks are detected, repair leak and recheck for additional leaks.
b) If no leaks are discovered, evacuate system as per accepted industry procedures.
11. Install a permanent high side access port for future system diagnostics.
12.Charge the system and check for proper operation.
WARNINGS
DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND
FOLLOW PROPER LOCKOUT/TAGOUT PROCEDURES.
WARNING: THIS PROCEDURE REQUIRES THE USE OF REFRIGERANTS. BE
CERTAIN THE WORK AREA IS WELL VENTILATED. SAFETY GOGGLES AND
GLOVES SHALL BE WORN SINCE REFRIGERANTS MAY CAUSE INJURY TO THE SKIN.
Otros manuales para KROGER RBC100
3
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Enfriador de Traulsen

Traulsen
Traulsen TBC13 Manual de usuario

Traulsen
Traulsen KROGER RBC100 Guía de configuración

Traulsen
Traulsen KROGER RBC100 Manual de usuario

Traulsen
Traulsen TBC5 Manual de usuario

Traulsen
Traulsen KROGER RBC50 Manual de usuario

Traulsen
Traulsen KROGER RBC200 Manual de usuario

Traulsen
Traulsen RBC400 Manual de usuario

Traulsen
Traulsen TBC5 Guía de configuración