TPI Scope Plus 460 Manual de usuario

460 Handheld 20MHz
Digital Oscilloscope
User’s Guide
Test Products International, Inc.
9615 SW Allen Blvd.
Portland, OR 97005
P : 503-520-9197 !Fax: 503-520-1225
E-mail: info@tpi-t evalueleader.com
The Value Leader
www.tpi-thevalueleader.com
TM

Copyrig t ©2001
Test Products International, Inc.
All Rig ts Reserved
08/01
460 User’s Guide
ii

Table of Contents
C1 - Introduction........................................................................................C1-1
Features ..........................................................................................C1-2
Specifications ..................................................................................C1-3
Scope Modes ........................................................................C1-3
Multimeter Modes ................................................................C1-5
C2 - Getting Started ..................................................................................C2-1
Equipment Needed ..........................................................................C2-1
460 Setup ........................................................................................C2-1
Measuring Voltage ..........................................................................C2-3
Measuring Frequency ......................................................................C2-3
Measuring Resistance......................................................................C2-4
Testing Continuity ............................................................................C2-4
Diode Test........................................................................................C2-4
C3 - Operation............................................................................................C3-1
Principal Connectors and Keys ........................................................C3-1
Key / Screen Menus ........................................................................C3-3
C4 - Advanced Functions ..........................................................................C4-1
Triggering ........................................................................................C4-1
Trend Mode......................................................................................C4-1
Glitc Capture ..................................................................................C4-2
Saving Screens ................................................................................C4-2
Using t e 10:1 Probe ......................................................................C4-3
10:1 Probe Compensation Adjustment ............................................C4-3
C5 - Using Adapters ..................................................................................C5-1
Temperature Adapter - A301............................................................C5-1
Hig Current Adapter - A251 / A256 / A296 ....................................C5-1
Low Current Adapter - A254............................................................C5-2
460 User’s Guide
iii

Current S unt Adapter - A130 ........................................................C5-2
Pressure Adapter - A620 ................................................................C5-2
PC Software & RS232 Cable - A404................................................C5-3
C6 - Safety Considerations ........................................................................C6-1
Instrument ......................................................................................C6-1
Environmental..................................................................................C6-2
Appendix A - Test and Calibration ................................................................A-1
Appendix B - Maintenance Considerations ..................................................B-1
Appendix C - Glossary ................................................................................C-1
Appendix D - Optional RS-232C / PC Interface............................................D-1
Appendix E - Troubles ooting ......................................................................E-1
iv
460 User’s Guide

Chapter 1
Introduction
T is manual describes t e TPI Scope Plus 460 and its functions. Normal and advanced functions
are covered in detail, as well as interactions wit computers and ot er instrumentation. A full
c apter is also devoted to safety considerations, bot instrument based and interactively. T e fol-
lowing is a brief c apter and appendix summary:
C apter 1 - Covers t e introduction, features and Specifications.
C apter 2 - Getting Started gets t e new user up and running in t e s ortest time possible.
T e basic functions are introduced in a ands on style designed to familiarize t e
user wit t e keypad and screen display.
C apter 3 - Explains all t e normal functions of t e TPI Scope Plus 460, including buttons,
menus, screen displays, and a sequencing guide for bot external key actions and
t eir interaction wit software driven menus.
C apter 4 - Explains more advanced functions suc as triggering, glitc capture, trend mode,
and saving screens.
C apter 5 - Explains and illustrates uses of probes and adapters including pressure,
temperature, and current s unt adapters. T is c apter also introduces general
aspects of t e optional optically isolated RS-232 interface.
C apter 6 - T is important c apter details operating met ods and tips designed to preserve
bot t e life of your instrument, and safety factors to prevent uman injury. T e
text is divided into Instrument and environmental safety subsections.
Appendix A - T is appendix covers w at to look for, and ow to make simple tests to find out if
your TPI Scope Plus 460 requires replacement parts or calibration.
Appendix B - T is Maintenance appendix gives tips on ow to keep your TPI
Scope Plus 460 in top operating condition by assuring constant
peak performance. T e appendix also covers battery servicing
and replacement.
Appendix C - A glossary describing t e meanings of terms associated wit t e
460 and its working environment.
Appendix D - T is appendix introduces and explains t e powerful RS-232C
Interface option. All aspects are covered from Installation to
460 User’s Guide Introduction
C1-1

Special Applications.
Appendix E - T is Troubles ooting appendix covers problems t at may arise
during installation or operation of your new TPI Scope Plus 460.
Features
The following features exist for the TPI Scope Plus 460:
"20 MHz Bandwidth
nough bandwidth to capture signals from AC/DC drive motors, sensors,
actuators, line and control voltages, UPS and industrial machines.
"Sample Rate
A real time sampling of 25 megasamples/sec to capture spikes and dropouts of
industrial signals.
"Dual Input
View two waveforms on the display for comparison and troubleshooting.
"T ue RMS DMM
Includes a 4000 count True RMS DMM that measures AC/DC volts to 600V,
frequency to 20MHz, resistance to 20M Ohm, diode test and continuity audible
tone.
"Auto anging
Autoranging capability across Voltage, Timebase and Frequency.
"B ight LCD Backlight
asy-to-see display in any light condition with user-adjustable backlight
brightness levels
"Optically Isolated RS232 Output
Transfer data safely without any direct connections to your computer’s systems
security.
"Optional Accesso ies
Temperature Adapter to measure temperature from -40 to 500oF (A301).
Pressure Adapter to measure pressure from -30 to 500psi (A620).
Protective Boot (A405).
Soft Carrying Case with Shoulder Strap (A905).
RS232 cable and software (A404).
Current Adapters:
o A254 - For measuring low current in milliamps
o A256 - Up to 400 AC/DC amps
460 User’s Guide Introduction
C1-2

o A296 - Up to 1000 AC/DC amps
Specifications
Display:
Size 76mm X 76mm (3" X 3")
Pixels 240 X 240 pixels
LCD type STN Normally Gray or Black
Back Lig t CCFL
Memo y:
Waveform Screens (2)
Setup User setup (1)
Powe :
External Power Adapter (5.5V / 2A)
Internal Battery Ni-MH 1.2V X 4
Battery Operating Time More t an 2.5 ours wit brig t backlig t
C arging Time 10 ours
SCOPE MODES
Ho izontal:
Samples per division 25 samples / div.
Time/division Equivalent sampling 50ns to 500ns/div
Real time sampling 1us to 2s/div
Modes Single, Normal, Auto, Glitc
Accuracy Real time sampling +/- (0.1% + 0.04 time/div)
Equivalent sampling +/- (0.5% + 0.08 time/div)
Ve tical:
Sampling Rate 25 Mega samples per second
Bandwidt DC Coupled 1:1 s ielded test leads ; DC to 10MHz
10:1 probe ; DC to 20MHz
AC Coupled 1:1 s ielded test leads ; 10Hz to 10MHz
10:1 probe ; 10Hz to 20MHz
Resolution 8 bits
C annel 2
Coupling AC,DC,GND
Input impedance Approx. 1M O m
Sensitivity 50mV to 200V/div 1,2,5 sequence
460 User’s Guide Introduction
C1-3

Accuracy +/- (3% + 0.05 range/div)
Display modes CH1, Dual
Maximum Input Voltage 600V
T igge :
Position Ver 1; Fixed Position / Ver 3; Adjustable Position
Mode Free run, normal
Source Internal (CH1/CH2)
Slope Positive/Negative
Sensitivity Real time sampling .... 2 divisions or more
Equivalent sampling .... 3 divisions or more
T end Plot:
Plot Time 30sec/div to 1- our/div
Plot Data Type Max / Min Selectable
Tempe atu e Measu ement:
Optional Adapter A301 (k - Type t ermocouple)
Range -40 F to 500 F
Accuracy +/- (1.5% + 5 digits)
P essu e / Vacuum Measu ement:
Optional Adapter A620
Range Pressure 500 psi
Vacuum 30 inHg
Accuracy Pressure +/- (5% + 5 digits)
Vacuum +/- (1.5% + 5 digits)
Cu ent Measu ement:
Optional Adapter 1 A251 (AC AMPS)
Range 0 - 40A / 40 - 400A
Accuracy ( 0 - 40A ) +/- (2.0% + 10 digits , 50 / 60 Hz)
(40 - 400A) +/- (2.0% + 10 digits , 50 / 60 Hz)
Optional Adapter 2 A256 (AC/DC AMPS)
Range 0 - 40A / 40 - 400A
Accuracy ( 0 - 40A ) +/- (2.0% + 10 digits , 50 / 60 Hz)
(40 - 400A) +/- (2.0% + 10 digits , 50 / 60 Hz)
Optional Adapter 3 A296 (AC/DC AMPS)
460 User’s Guide Introduction
C1-4

Range 0 - 400A / 400 - 1000A
Accuracy ( 0 - 400A ) +/- (2.0% + 10 digits , 50 / 60 Hz)
(400 - 1000A) +/- (2.0% + 10 digits , 50 / 60 Hz)
MULTIMETER MODES
DC Volts (CH1/CH2)
Range Resolution Accu acy
400mV 0.1mV +/- (0.5% + 5 digits)
4V 0.001V +/- (0.5% + 5 digits)
40V 0.01V +/- (0.5% + 5 digits)
400V 0.1V +/- (0.5% + 5 digits)
600V 1V +/- (0.5% + 5 digits)
AC Volts (CH1/CH2)
Range Resolution Accu acy
400mV 0.1mV 20Hz to 50Hz; +/- (2% + 20 digits)
4V 0.001V 50Hz to 1kHz; +/- (1% + 10 digits)
40V 0.01V 1kHz to 20kHz; +/- ( 2% + 10 digits)
400V 0.1V 40Hz to 400Hz; +/- (1% + 10 digits)
600V 1V 40Hz to 400Hz; +/- (1% + 10 digits)
F equency (CH1/CH2)
Range Resolution Accu acy
100Hz 0.01Hz +/- (1.0% + 10 digits)
1KHz 0.1Hz +/- (0.5% + 5 digits)
10KHz 1Hz +/- (0.5% + 5 digits)
100KHz 10Hz +/- (0.5% + 5 digits)
1MHz 100Hz +/- (0.5% + 5 digits)
10MHz 1kHz +/- (0.5% + 5 digits)
20MHz 10kHz +/- (2.5% + 5 digits)
OHM (CH1 ONLY)
Range Resolution Accu acy
400 O m 0.1 O m +/- (0.75% + 5 digits)
4k O m 1 O m +/- (0.5% + 5 digits)
40k O m 10 O m +/- (0.5% + 5 digits)
400k O m 100 O m +/- (0.5% + 5 digits)
4M O m 1k O m +/- (1.0% + 10 digits)
20M O m 10k O m +/- (3.0% + 20 digits)
460 User’s Guide Introduction
C1-5

Continuity (CH1 ONLY)
Range Resolution Accu acy
4 K o m 1 o m Beeps < 0.1 K o m , +/- (2% + 5 digits)
Diode (CH1 ONLY)
Range Resolution Accu acy
4 V 1 mV Open circuit voltage < 5 V
S ort circuit current < 5 mA
Reading accuracy; +/- (2% + 5 digits)
460 User’s Guide Introduction
C1-6
Tabla de contenidos
Otros manuales de Equipo de prueba de TPI
Manuales populares de Equipo de prueba de otras marcas

SMART
SMART KANAAD SBT XTREME 3G Series Manual de usuario

Agilent Technologies
Agilent Technologies BERT Serial Manual de usuario

Agilent Technologies
Agilent Technologies N3280A Manual de usuario

Vernier
Vernier Go Direct Voltage Manual de usuario

Lifeloc
Lifeloc R.A.D.A.R. Manual de usuario

Fluke
Fluke T5-600 Instrucciones de funcionamiento e instalación