5. Cabtyrecable
a)The useofacabtyrecablewhichhasan inferiorsection orasuperiorlengththen
recommended can makethe starting up ofthepumpimpossibleand provokedamages
tothe motor.
Concerning thecharacteristics ofthe cabletouse,pleaserefertothe technical
characteristics of thepump.
b)Toavoidtearingoutthecable,makesurethatthe lengthofthe alimentationcable
correspondstothe depthat whichthe pumpwillhavetowork.
Whenlengtheningthecable,whichisfixed tothe pumpwithasecond cable,you
shouldmakesurenot tosubmerge theirconnection.
6. Dischargehose
The diameterofthe discharge hosefixed tothe pumphastobe adapted tothe
diameterofthe hosenippleofthepump.Thedischargehosewillpreferablybe fixed
withhalf-circularcollars.
NOTES ONDRIVING
a)Foryoursafety,nevertouchthe agitatorwhenthe pumpisconnected,andneverpass
underneaththepumpwhileitissuspended.
b)When the pumpisinduty, it hastobe immersed untilthe levelindicated on the schema
representing the dimensionsofthe pump.
c)If possible,avoidusing the pumpinconditionsthatprovokean overload.
See inparticulartoimmersethe pumpprogressivelyuntilthe materialtopumpis
reached.
d)Inspectthe good working condition ofthe pumpbysecuring thatthe intensityofthe
currentdoesnot exceed the value indicated onthe identification plateof the pump.
e)Avoidsuspendingthepump(verticalmodels)insuchwaythat itmightget buriedatthe
bottom.
f)Oncethelevelofthepumped liquidbecomesinsufficient, noisy functioning and
abnormalweararegenerated. Inthiscase, add liquidorstop the pumpand wait forthe
liquidtorise.
g)Despitetheeffectofthe agitator,oversized materials,suchaspiecesofwood,etc.
havethe propensitytopresentthemselvesatthe entranceofthe pump.Thereforethe
pumphastobe equippedwithironbarspermitting objectsofthe samedimensionas
the holesof the strainer. Consult yoursupplier.