Threequickbeeps=Incorrectand mustbere-entered
Programming begins by entering aFunction Key Por Lor SthenyourPasscode, andthen
theproperfunctionwilldisplaytoshowontheLEDscreen.Youwouldthen enterthespecific
programmingoptionsasstated ineachprogrammingstep.When thatprogrammingstepis
completed,wait untiltheLEDdisplay isoff, followed by 3quick beeps.Thenproceedtothe
nextprogramming stepasdesired.TheControlPanelutilizesIntelligentStoringCapabilityto
storeprogramminginformation(data).Onceyouhaveenteredtheprogramming dataforany
function,theControlPanelwillautomaticallystorethat data.Thedatawillremainsecureinthe
unit’smemoryuntil changedbyauser,evenintheeventofapowerfailureoroutage.
Keep inmind thatyou can,atany time,change the programmedsettings ofany function.Justfollow
theprogrammingstepsoftheparticularfunctionyouwouldliketochange.
NOTE: Ifyoupausewhileenteringprogrammingsequence,theunitmaynotacceptit.Ifthis
occurs,enterthesequenceagain.
Step1–ProgramUserPasscode(Default:1234)
ThedefaultUserPasscodeis“1234”andcan bechanged if necessary.Tochange theUser
Passcode,followthestepsbelow.
1) Enterthe Pkey
2) Enterthedefault Passcode: 1234
3) Waituntil theLEDdisplays“P”
4) Enterthe Ýkey
5) Enteryournew4-digit Passcode
6) Youwillhearaconfirmationtone,andtheinformationisstored(Onelongbeep =
correctentry/Three quickbeeps =incorrectentrymustbere-entered)
Step2–ProgramAuto-DialerTelephoneNumbers
Thisfunctionallowsforuptosixphonenumberstobeenteredintothe Auto-Dialer, eachofwhich
willbecalledinsequenceintheeventofanalarmactivation.
NOTE: Inmost cases, it isrecommendedtohavethesystemcallouttousers,familymembers,
neighborsandsoon, ratherthanto911orthepolice. Thisallowsacall recipienttorespondto
the AlarmNotificationCall and decidewhetherit maybeafalsealarmornot.Thenthecall
recipientcancall 911, thepoliceorotheremergencyassistanceifdeemednecessary.
1) Enterthe Pkey
2) Enteryournew(ordefault)Passcode: xxxx
3) Waituntil theLEDdisplays“P”
4) Enterthe 1keytoprogramthefirstphonenumbertobedialed(Foreachof the
secondthroughsixthphonenumbers,repeat thisentireprogrammingstageandenter
2~ 6atthisstep)
5) Enterthephonenumberof choice,up to16digitsincludingpauses(Fordialingouton
aPBX systemorsimilar,youcanadda“pause”tothephonenumberbyentering Ý
withinthenumber.Forexample,9*12125551212woulddial 9, thenpausefor2
seconds, thendial1,theareacodeandnumber)
6) Withinafewsecondsyouwill hearaconfirmationtone,andtheinformationisstored
(One longbeep =correctentry/Threequickbeeps=incorrectentrymustbe
re-entered).TheLEDwillflashtheprogrammedphonenumberforconfirmation.
Step3–ProgramAutomaticDialingCycles(Default:2cycles)
Thisfunctionisforuserstoprogramtheamountof timesthe systemwilldialtheentiresequence
ofprogrammedphone numbers.Thefactorydefault issetupfor2times(2cycles).You can
programitforupto9cycles.
1) Enterthe Pkey
2) Enteryournew(ordefault)Passcode: xxxx
3) Waituntil theLEDdisplays“P”
4) Enterthe 7key(CommandCodeforthisfunction)
5) Enter 1~ 9dependingontheamountofcyclesyoudesire
6) Withinafewsecondsyouwill hearaconfirmationtone,andtheinformationisstored
(Onelongbeep =correctentry/Threequickbeeps=incorrectentrymustbere-entered)
Step4–ProgramZone1Entry/ExitDelayTime(Default:20seconds)
ThisfunctionisforuserstoentertheZone1entry/exitdelaytimeduringFull ArmingorPartial Arming
Mode. Thefactorydefaultis20seconds.Youcanprogramfrom0~90secondentry/exit delay.
1) Enterthe Pkey
2) Enteryournew(ordefault)Passcode: xxxx
3) Waituntil theLEDdisplays“P”
4) Enterthe 8key(CommandCodeforthisfunction)
5) Enter 0~ 9dependingontheamountofdelaytimeyoudesire(Thisnumberwillbe
automaticallymultipliedby10fortheactualamountofseconds)
6) Youwillhearaconfirmationtone,andtheinformationisstored(Onelong beep=
correctentry/ Threequickbeeps =incorrectentrymust bere-entered)
Step5–ProgramAlarm/SirenDuration(Default:4 minutes)
Thisfunctionisforuserstoprogramtheduration(lengthoftime)thatthesirenwillsoundupon
alarmactivation. Thefactorydefaultis4minutes. Youcanprogramfrom0~18 minutes.
Howtomanuallyresetbacktothefactorysettings?
Ifyou forgotyourPasscode,orwanttoresetthesystemtoitsoriginal defaults,followthe
procedurebelowtoperformaGlobalReset(resetsPasscodeand allprogramming
functionstothefactorydefaults):
1) UnplugthePowerAdaptorandremovethe RechargeableBackup Batteries
2) Pressandholdthe Ýand #keysat thesametime
3) Whileholdingdownthekeys, pluginthe PowerAdaptortopowerunit on
4) Afteronesecond,theunitwill beeptoconfirmthat theGlobal Resetwas
successful
5) ThePasscodeandall UserFunctionswillbesettothefactorydefaults
NOTE:IfGlobal Resetwasunsuccessful, repeatthesameprocedureabove