AM1-AM15
Bia ostoczek26,gm.Zab udów,15
592 Bia ystok; Poland ; Tel. +48 857431246; VATPL5420008413
Minimalflowofwaterisnot required.
Increased flowthroughthe sterilizerlowersthe dosagedelivered tomicroorganismsand
lowersefficiencyofdisinfection,however,itallowsforuseininstallationswithoutthe need
foradditionalbypasses.
StandardFeatures:
-electricalenclosure,
-lampworkinghourscounter,
-audibleand opticalalarm
-terminalsforconnectingelectromagneticvalveshuttingoff flowincaseofpoweror
lampfailure
OptionalAccessories:
1. UV intensitysensor.
4.Description
Sterilizer’schamberismade fromstainless steel.QuartzsleeveswithUVlampsare
mounted inthe chamber.
When mounted vertically,the inletshouldbe located inthe bottompartofthe chamber
and the outletinthe upperpart. When mounted horizontally,the arrangementisoptional.
At the bottomofthe chamberthe drainplugislocated,whichisused toemptythe
chamberfromfluid.The powersupplysystemismounted inthe electricalenclosureand
connected withthe sterilizerbyhi-potentialwires.The enclosurehouses,besidesthe
powersupply,the lampworkinghourscounter,the audibleand opticalalarm,and
indicatinglightswiththe terminalsforelectromagneticshutoff valveincaseoflampor
powerfailure.
4.1.Leading outthealarm signal inAM1model
Tothe terminals1& 2on electronicplate/neutral/ connect alarmsignal.
·Contactsclosed -sterilizerworkingproperly
·Contactsopen -UV lampdamage
-Alarmon
-Powercut off
4.2.Connection ofsolenoidvalveinAM1model
Tothe terminals1& 2/neutral/ on the electronicplateinelectricalenclosure/ connect
solenoidvalvetype NZ(normallyclosed)max. 2a.
·Contactsclosed -sterilizerworkingproperly
·Contactsopen -UV lampdamage
-Alarmon
-Powercut off
4.3.Remote-controlledswitchinAM1model
Afterremovingthe bridge, it ispossibletoconnect remote-controlled switchtothe
terminalsON/OFF /caution:voltage230V!/.
·Contactsclosed -sterilizeron
·Contactsopen -sterilizeroff