Titan TT-ACP10C02 Guía

INSTALLATION & ASSEMBLY
PORTABLE(AIR(CONDITIONER(
TT-ACP10C02

Installation Safety
●Observe all applicable state and local codes and ordinances.
●Do not use a damaged or non-standard power cord.
●Use caution during installation and maintenance. Incorrect operation can
cause electric shock, resulting in injury or death.
WARNING
Selecting an installation location
Basic requirement
Installing the unit in the following areas may cause it to malfunction:
Air conditioner requirements
1. Keep the air inlet clear of obstacles. Blocking the inlet can affect radiation of the heat
discharge pipe.
2. Select a location where the noise and outflow air emitted by the outdoor unit will not pose
a nuisance.
3. Keep the unit as far away as possible from fluorescent lamps.
4. Do not install this appliance in a bathroom or laundry room.
20
1. Close to strong heat sources, flammable or explosive vapors or gas (such as sulphur
gas), or projectile objects.
2. Close to high-frequency devices such as welding machines or medical equipment.
3. Coastal areas.
4. Areas containing oil or fumes in the air.
5. Other locations with unusual features that may pose a hazard to the appliance. Consult
your local dealer for help with optimal placement.

Installation Safety
Requirements for electrical connection
Safety precaution
1. Follow all applicable state and local safety regulations when installing and grounding
this appliance.
2. Ensure the safety of the power supply circuit prior to installation.
3. Be sure to properly connect the live wire, neutral wire and grounding wire of the power
socket.
4. Be sure to cut off the power supply before proceeding with any work related to electricity
or safety.
5. Do not connect the appliance to a power source until installation is complete.
6. This air conditioner is a first class electrical appliance. It must be properly grounded by
an electrician or similarly qualified professional. Failure to ensure proper grounding may
result in electric shock.
7. The yellow-green or green wire in the air conditioner is the grounding wire. Do not use it
for other purposes.
8. For appliances with type Y attachment: If the supply cord is damaged, it must be
replaced by the manufacturer, service agent, or service professional in order to avoid
hazard.
21
WARNING:

Optional
Bracketscrew
22
Before You Install
Note: Check to ensure that all of the accessories listed here are included with this air
conditioning unit.
Note: The following accessories are not included with all models.
Accessory list
Tools needed for installation
cross screwdriver
gauge
straight screwdriver
scissors
saw
pencil
heat discharge pipe
Joint Window
adapter(top)
Window
adapter(bottom)
remote controll user's manual
battery
(AAA 1.5V)
screw
Foam seal A Insect guard net
wire hook
Adapter
Foam seal B
(adhesive type)
Rain guard
Window kit
Window panel
Exhaust cover
Adjustment panel
Extension panel

23
Installing Wire Hook
●Assemble the wire hook at the back of the unit with screws (orient the wire
hook as shown in the following figure).
●Wind the power cord around the wire hook.
direction of wire hook is upward
direction of wire hook is downward
screw
wire hook

24
Removing Collected Water
There are 2 ways to remove collected water:
1
Use the continuous drainage option from the bottom hole.
1.
■Drainsas follows.
2.
During cooling or drying operations, condensed water will drain to the chassis and
be spattered as it strikes the motor. As the condenser is hot, most of this
condensation will evaporate and drain to the outdoors on its own. Very little
condensed water will accumulate inside the chassis, so you will not need to
discharge the water frequently.
drainage port
Once the chassis is full of water, the unit will buzz 8 times and the "H8" code will
display to remind you to discharge the water:
Move the unit to a suitable place for discharging water. Keep the unit horizontal
when moving; do not tilt.
Remove the rubber plug at the drainage port to discharge the water.
Put the rubber plug back into the drainage port after the water has drained out.
The H8 display will disappear. Once the compressor has been stopped for 3
minutes, the unit will resume operation.

1.
2. Screw the drain connector (included)
to the spout by turning it clockwise.
3. Insert the drainage hose into the
drain connector.
Removing Collected Water
Note:Water can be automatically emptied into a floor drain by attaching a 14mm
inner diameter hose (not included).
Use the continuous drainage option from the middle hole
ATTENTION:
When using the continuous drainage option from the middle hole, place the unit
on a level surface and make sure your garden hose is clear of any obstructions
and is directed downward. Placing the unit on an uneven surface or failing to
attach the hose properly may result in water filling up the chassis, which will
cause the unit to shut off. If this occurs, empty the water in the chassis and
check to make sure that both the unit and the hose are properly set up.
25
2
Remove the continuous drain cap (1) by turning it counterclockwise, then remove
the rubber stopper (2) from the spout.

26
Installation in ADouble-hung Sash Window(Optional)
3.
4. Attach the window panel to the window stool.
Make sure that the exhaust cover is attached to the window panel.
Inner width of the window: 20.5"(520mm)
Use the window panel.
Cut the Foam seal B (adhesive type) to the proper length and attach it to the
window stool and to the bottom of the window sash.
Foam seal B (adhesive type)
1. Connect the rain guards to the insect guard net.
Insert all three projections on each rain guard into the holes in the insect guard net.
2. Attach the combined guard as shown above to the window panel.
Side “A” will now be at the top, as indicated in the diagram.
Push the insect guard net firmly to ensure that its four projections fit into the holes
in the window panel.
Side “A” will now be at the top, as indicated in the diagram.
Hole
Projec-
tion
Insect guard net Rain guard
"A"
Window panel
Projection
"A"

Installation in ADouble-hung Sash Window(Optional)
27
The window panel cannot be installed in windows less than 20.5" (520mm)
wide,as you will be unable to shut the exhaust cover.
Inner width of the window: 20.5" (520mm)-37.4" (950mm)
Use the window panel and the adjustment panel.
Inner width of the window:37.4" (950mm) - 56.7" (1440mm)
Use the window panel, the adjustment panel and the extension panel.
20.5"
Window panel
Exhaust cover
20.5" - 37.4"
37.4" - 56.7"
(1) Open the window sash and place the window panel on the window sill.
(2) Secure the window panel to the window stool with screws.
(1) Open the window sash and place the window panel on the window sill.
(2) Slide the adjustment panel to fit the window frame width.
(3) Secure the window panel to the sill with screws.
(1) Open the window sash and place the window panel on the window sill.
(2) Slide the adjustment and extension panels to fit the window frame width.
(3) Secure the window panel to the window sill with screws.
Adjustment panel
Extension panel
Adjustment panel

Installation in a Double-hung Sash Window(Optional)
28
6. Stuff the Foam seal A between the glass and the window to prevent air and insects
from getting into the room.
5. Close the window sash securely against the window panel.
Tabla de contenidos