Timpani BATTERYPAR45 Manual de usuario

www.timpani.it
BATTERYPAR45
9PCS*12W RGBWA+UV LED PAR (6IN1)

www.timpani.it
USER MANUAL
P
le
a
se
rea
d
t
he
ins
t
r
u
ction
s
ca
refu
ll
y before use

www.timpani.it
TABLE OF CONTENTS
1.
S
af
ety
I
nst
r
uctions.................................................................................................
4
2. Technical Specifications........................................................................................
7
3. How To Control The Unit.......................................................................................
7
4. Menu...................................................................................................................9
5. DMX Channel.....................................................................................................10
6
. Remind..................................................................................................................
11

www.timpani.it
statement
The product has well capability and intact packing when leave factory. All of the
user should comply with warning item and manual, any misuse cause of the
damages are not included in our guarantee, and also can not be responsible for
any malfunction & problem owing to ignore the manual.
1. SafetyInstructions
Please keep this User Guide for future consultation. If you sell the unit to another user,
be sure that they also receive this instruction booklet.
Unpack and check carefully there is no transportation damage before using the unit.
Before operating, ensure that the voltage and frequency of power supply
match the power requirements of the unit.
It’s important to ground the yellow/green conductorto earth in order to avoid electric
shock.
The unit is for indoor use only. Use only in a dry location.
The unit must be installed in a location with adequate ventilation, at least 50cm
from adjacent surfaces. Be sure that no ventilation slots are blocked.
Disconnect main power before replacement or servicing.
Make sure there are no flammable materials close to the unit while operating as it is fire
hazard.
Use safety cable when fixes this unit. DO NOT handle the unit by taking its head only,
but always by taking its base.
Maximum ambient temperature is Ta: 40℃. DO NOT operate it where the temperature is
higher than this Unit surface temperature may reach up to 85℃. DO NOT touch the

www.timpani.it
housing bare-hand during its operation. Turn off the power and allow about 15 minutes
for the unit to cool down before replacing or serving.
In the event of serious operating problem, stop using the unit immediately.Never try
to repair the unit by yourself. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical assistance
center. Always use the same type spare parts.
DO NOT touch any wire during operation as high voltage might be causing electric
shock.
Warning:
Please set one light only as master when used Master-slave model in the same
channel.
DO NOT set any light as master when used DMX hold model.
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain
or moisture.
DO NOT open the unit within five minutes after switching off.
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
damaged.
Caution:
There are no user serviceable parts inside the unit. DO NOT open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact your nearest dealer.
Installation:
The unit should be mounted via its screw holes on the bracket. Always ensure that the
unit is firmly fixed to avoid vibration and slipping while operating. And make

www.timpani.it
sure that the structure to which you are attaching the unit is secure and is able to
support a weight of 10 times of the unit’s weight. Also always use a safety cable that
can hold 12 times of the weight of the unit when installing the fixture.
The equipment must be fixed by professionals. And it must be fixed at a place where is
out of the touch of people.

www.timpani.it
2. Technical Specifications
Light Sources: 9pcs*12W RGBWA+UV LED
Beam Angle: 15°
Power Consumption: 160W
Voltage: 12.6V
Stored electricity: 14ah
Lifespan: charge-discharged for about 400 times
Net Weight: 5Kgs
Control
DMX Channel: 7/11 Channel
Control Modes: DMX and wireless
Construction
Display: OLED Display
Data In/Out socket: 3-pin XLR sockets
Power Socket: Powercon in/out
Protection Rating: IP65
Features
* OLED display
* Powercon True One in/Out
* Option for change LED Power (Eco, Medium, High power)
* Battery Charging Information and Wireless Channel change in Display
* Emergency Mode (enable / disable)
* DMX hold (on/off)in display

www.timpani.it
* Working hours: battery could run over 20hrs (single white color)/ 4.5 hrs ( full color)
on a full charge;
3.
How To Control The Unit
Th
e
D
M
X512
is
w
id
ely
us
ed
in intellig
ent
ligh
ti
ng
co
n
tr
ol,with a DMX 512
controller.connect several lights together,dmx in and dmx out,
3
pin
XLR
co
nn
ectors
:
Pin
1:
G
ND
,
Pin
2:
Nega
tive
s
ig
n
a
l
(-),
Pin
3:
P
o
s
itive
s
i
g
na
l
(+)

www.timpani.it
Display:
MENU To select the programming functions
DOWN To go backward in the selected functions
UP To go forward in the selected functions
ENTER To confirm the selected functions
Set DMX Address Code
1. Press "Menu" to "Set DMX Address",and press"ENTER" keys to enter into
2. Show "Set DMX Address DMX Address:001",Press the "UP and DOWN"
keys to amended
4.Turn on operation: when in charging or turn off, press "MENU" for more than 4s,
then screen will display clients' logo and model of products,
there are "MENU","UP"."DOWN" for your selection to choose the function,press" E
NTER" to confirmed and enter the next menu,press "MENU" could back
to the last menu.
When turn on , press" MENU" for more than 4s,the screen will display " Power Off",
and will close LED output by then.
If charger connect with electricity,the screen will display charging icon and percenta
ge of battery power. Or will be turn off directly,
and the battery powered wll be totally cut off
5. When using Master-Slave model,apart from the first one as Master without
setting,the others need to set as Slave.
6. When using DMX512 controller,all the lights need to set as DMX model.

www.timpani.it
MENU
Choose Pattern
Static Color
Static Color
Show Mode
Sound model
User Colors
User Run
RGBW (0-255) Strobe( 0-255)
001-016
AUTO / FADE / SNAP / STRO(RGBA)
Sound ( 1-3) outdoor no the function
RGBW ( 000-255) Bank: 1/16
1. Static Color
2. Auto Mode
User setting
Channel
DMX512 Address
Slave Mode
7-CH / 11CH
001-512
System setting
White balance
Show Battery
Display sleep
Dimmer option
RF 2.4 setting
RF 2.4 FREQ
Power Setting
Emergency Lamp
DMX Hold
RGBW ( 0-255)
Yes / No?
Open/5Sec/10Sec/15Sec
Normal - lowest
Yes/No
1CH-7CH
High / Medium / Low
Yes / No
Yes / No
Tabla de contenidos
Otros manuales de Equipo de DJ de Timpani
Manuales populares de Equipo de DJ de otras marcas

thomann
thomann Stairville DJ Lase 40-G MK-III Manual de usuario

Eagletone
Eagletone 6 Eyes Flower Manual de usuario

EuroLite
EuroLite FLD-1508 Manual de usuario

Technical Pro
Technical Pro LG8xSEA Manual de usuario

JB Systems
JB Systems Lounge Laser DMX Manual de usuario

Lightmaxx
Lightmaxx Vega Halo 90 Manual de usuario

Elation
Elation FUZE WASH Z350 Manual de usuario

Maverick
Maverick MK3 WASH Manual de usuario

Infinity
Infinity TF-260C7 Fresnel Manual de usuario

Chauvet
Chauvet EVE E-50Z Manual de usuario

Eliminator Lighting
Eliminator Lighting E 138 Manual de usuario

EuroLite
EuroLite Mini Multicolor LED Flashing Light SC Manual de usuario







