Pag. 5 / 9DMAN63W0000020-2Ways2 Manual - System100 Hydro STD2
Er18: Run out of pellet
Er23: Boiler probe or Buffer probe open
Er25: Error Engine cleaning Brazier
Er39: Air Flow Regulator Sensor broken.
Er41: Minimum air flow in Check Up not reached.
Er42: Maximum air flow Up reached (F40).
Er44: Open door error.
Er47: Auger Encoder error, no Encoder signal.
Er48: Auger Encoder error: auger speed regulation failed.
Er52: I/O I2C Module error
Er57: Test ’Forced Draught High’ in Check Up fail (FL70)
Service: It notifies that the planned hours of functioning (parameter T66) is reached. It is necessary to
call for service.
-Other messages:
Prob: Visualization of the state of temperature probes. The message displayed in Check-Up indicates
that the red temperature on one or more probes is equal to the minimum value (0°C) or maximum (it
depends on probe considered). Check that the probes aren’t open (0°C) or in short-circuit (maximum
value of the temperature scale).
Clean: This message notifies that the planned hours of functioning (parameter T67) is reached. It is
necessary to clean the stove or boiler.
Block-Ignition: The message appears if the system is turned off during Ignition (after Preload) by an
external device: the system will stop only when it goes in Run Mode.
Door: The message notifies that the door is open.
Cleaning On: Periodic Cleaning in progress.
-Battery Charge Level:
Battery discharged; replace the
battery as soon as possible. The
image blinks.
3The Menu
To enter the Menu press the SET key on the remote control. The Submenu list or the parameter list will
appear with the current set value:
The storage of a new value is associated to the transmission to the control board; if it fails the message
'Transfer not successful '
appears.
In this case try to modify again the parameter’s value.
Auger
C01 1.0_________
C02 1.2
C03 4.1
C04 5.6
C05 6.2
C05 7.4
C05 7.4
System Menu
Auger____________
Combustion Fan
Combustion Fan 2
Heating Fan
Thermostats
Timers
Auger
C01
Max: 60.0
Set: 1.0
Min: 0.0
Submenu
Parameter Code
Maximum Value
Current Value
Minimum Value