TIBCO LogLogic LX series Manual

TIBCO LogLogic®
Log Management Intelligence (LMI)
Hardware Installation Guide
Software Release: 5.3.1
August 2012

Important Information
SOME TIBCO SOFTWARE EMBEDS OR BUNDLES OTHER TIBCO SOFTWARE. USE OF SUCH EMBEDDED OR
BUNDLED TIBCO SOFTWARE IS SOLELY TO ENABLE THE FUNCTIONALITY (OR PROVIDE LIMITED ADD-ON
FUNCTIONALITY) OF THE LICENSED TIBCO SOFTWARE. THE EMBEDDED OR BUNDLED SOFTWARE IS NOT
LICENSED TO BE USED OR ACCESSED BY ANY OTHER TIBCO SOFTWARE OR FOR ANY OTHER PURPOSE.
USE OF TIBCO SOFTWARE AND THIS DOCUMENT IS SUBJECT TO THE TERMS AND CONDITIONS OF A
LICENSE AGREEMENT FOUND IN EITHER A SEPARATELY EXECUTED SOFTWARE LICENSE AGREEMENT,
OR, IF THERE IS NO SUCH SEPARATE AGREEMENT, THE CLICKWRAP END USER LICENSE AGREEMENT
WHICH IS DISPLAYED DURING DOWNLOAD OR INSTALLATION OF THE SOFTWARE (AND WHICH IS
DUPLICATED IN THE LICENSE FILE) OR IF THERE IS NO SUCH SOFTWARE LICENSE AGREEMENT OR
CLICKWRAP END USER LICENSE AGREEMENT, THE LICENSE(S) LOCATED IN THE “LICENSE” FILE(S) OF
THE SOFTWARE. USE OF THIS DOCUMENT IS SUBJECT TO THOSE TERMS AND CONDITIONS, AND YOUR
USE HEREOF SHALL CONSTITUTE ACCEPTANCE OF AND AN AGREEMENT TO BE BOUND BY THE SAME.
This document contains confidential information that is subject to U.S. and international copyright laws and treaties.
No part of this document may be reproduced in any form without the written authorization of TIBCO Software Inc.
TIBCO and LogLogic are either registered trademarks or trademarks of TIBCO Software Inc. and/or subsidiaries of
TIBCO Software Inc. in the United States and/or other countries.
All other product and company names and marks mentioned in this document are the property of their respective
owners and are mentioned for identification purposes only.
THIS SOFTWARE MAY BE AVAILABLE ON MULTIPLE OPERATING SYSTEMS. HOWEVER, NOT ALL
OPERATING SYSTEM PLATFORMS FOR A SPECIFIC SOFTWARE VERSION ARE RELEASED AT THE SAME
TIME. PLEASE SEE THE README.TXT FILE FOR THE AVAILABILITY OF THIS SOFTWARE VERSION ON A
SPECIFIC OPERATING SYSTEM PLATFORM.
THIS DOCUMENT IS PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, OR NON-INFRINGEMENT. THIS DOCUMENT COULD INCLUDE TECHNICAL
INACCURACIES OR TYPOGRAPHICAL ERRORS. CHANGES ARE PERIODICALLY ADDED TO THE
INFORMATION HEREIN; THESE CHANGES WILL BE INCORPORATED IN NEW EDITIONS OF THIS DOCUMENT.
TIBCO SOFTWARE INC. MAY MAKE IMPROVEMENTS AND/OR CHANGES IN THE PRODUCT(S) AND/OR THE
PROGRAM(S) DESCRIBED IN THIS DOCUMENT AT ANY TIME.
THE CONTENTS OF THIS DOCUMENT MAY BE MODIFIED AND/OR QUALIFIED, DIRECTLY OR INDIRECTLY, BY
OTHER DOCUMENTATION WHICH ACCOMPANIES THIS SOFTWARE, INCLUDING BUT NOT LIMITED TO ANY
RELEASE NOTES AND "READ ME" FILES.
Copyright © 2002- 2012 TIBCO Software Inc. ALL RIGHTS RESERVED.
TIBCO Software Inc. Confidential Information

1
Congratulations on purchasing a LogLogic Appliance!
The LogLogic® Appliance-based solution enables you to capture and manage log data
from all types of sources in your enterprise. LogLogic Appliances install within minutes
and begin collecting and aggregating data from connected log sources immediately.
Follow these steps to quickly install your LogLogic Appliance. For logging in and
configuring your Appliance refer to the LogLogic Installation and Upgrade Guide.
Step 1: Unpack and Verify Parts in the Kit
Unpack and verify the following parts are available in the kit.
Table 1 Appliance Kit Components
Item Qty Part Number Description
1. 1 N/A LogLogic Appliance
2. 2 403-0002-00 Power cords (Note: LX820 Appliance has only 1 power cord)
3. 1 706-0063-00 Rail Kit
4. 1 403-0014-00 Null modem cable, DB9 F/F, 6 feet
5. 1 100-0712-01 Documentation & Supplemental CD
6. 1 100-0725-01 Pre-ship FQC Checklist
7. 1 100-0736-01 Packing list
Rail Kit Components
1. 1 TW1-S28-96012-G
28” RAIL
2. 2 TW1-S28-20030-B
4” Adjust Bracket
3. 2 TW1-S28-20040-B
5” Adjust Bracket
4. 4 3E-100-03000-B
M5 Nut Plate
5. 4 3E-100-04000-B
M4 Nut Plate
6. 12 TW-000-30320-AR
M5 x 10.0L screws
7. 20 CS4+10FN
M4 x 10.0L screws
8. 10 CS4+4FN
M4 x 4.0L screws
9. 10 TW-000-30230-A
M5 x 10.0L screws

2
Step 2: Attach Mounting Rail Brackets
Figure 1 Rail Kit Components
Step 2: Attach Mounting Rail Brackets
The position of chassis and rails with a side view of cabinet with one-2U system is shown
below.
Figure 2 Side View of the Appliance
1. Remove the two identical main rails and the inner rails from the box.
2. Attach inner rails to chassis (either left or right side) by using M4x4.0L screws. Use 4
screws for 1U and 3 screws for 2U on each side.

3
Step 2: Attach Mounting Rail Brackets
Figure 3 Attach Inner Rails
3. For Cabinet with square mounting holes: Attach and screw in the adjustable rear
bracket to the outer rail as shown below (the rear bracket should be movable in front
and back).
Figure 4 Attach Rear Bracket
4. Follow the orientation specified below to install the outer rail and rear bracket with
screws and nut plates on the cabinet. Tighten the screws (as show in Figure 4) after the
whole outer rail set is mounted to the cabinet posts.

4
Step 2: Attach Mounting Rail Brackets
Figure 5 Install Outer Rails
5. For Cabinet with round mounting holes: Attach and screw in the adjustable rear
bracket to the outer rail as shown below (the rear bracket should be movable in front
and back).
Figure 6 Attach Rear Bracket
6. Follow the orientation specified below to install the outer rail and rear bracket with
screws and nut plates on the cabinet. Tighten the screws (as show in Figure 6) after the
whole outer rail set is mounted to the cabinet posts.

5
Step 2: Attach Mounting Rail Brackets
Figure 7 Install Outer Rails
7. Slide the chassis into the cabinet by inserting inner rails to the outer rail mounted in
the cabinet.
Figure 8 Slide the Chassis

6
Step 3: Connect Cables
Step 3: Connect Cables
1. Connect the power cables (located at the back side of the Appliance) as shown below.
Figure 9 Connected Power Cable (LX820 - 1 Power Cable)
Figure 10 Connected Power Cables (for 1U system)
Figure 11 Connected Power Cables (for 2U system)

7
Step 3: Connect Cables
2. Connect the Ethernet cables (located at the back of the Appliance) as shown below.
Note: These cables are not included in the kit.
Figure 12 Connected Ethernet Cables (for 1U system)
Figure 13 Connected Ethernet Cables (for 2U system)
3. For Setting up with Console – Connect one end of the Null modem cable located at
the back of the Appliance and attach the other end to a laptop or terminal device, for
example, HyperTerminal or puTTY.
Note: This step is required only when you are setting up the Appliance using the Console. If you
are setting up with a Browser, skip this step and go to Step 4: Power up the Appliance.
Figure 14 Connected Null modem cable (for 1U system)
Figure 15 Connected Null modem cable (for 2U system)

8
Step 4: Power up the Appliance
Step 4: Power up the Appliance
1. Press the Power button (located on the front side). In few seconds, the Power button
turns blue as shown below. When the operating system starts booting up, the LEDs
show blue color.
Figure 16 Power Button (for 1U system)
Figure 17 Power Button (for 2U system)
2. Wait for about 3 to 5 minutes for system to boot up. During this time, you can see
various messages appearing on the screen. Once the system boots up, the screen
displays the following prompt.
Figure 18 Appliance Booting Process Completed
Congratulations! You have successfully installed the LogLogic Appliance.
Step 5: Log into the Appliance
For instructions on how to log in to the Appliance using either Web browser or Console,
refer to the LogLogic Installation and Upgrade Guide.
Este manual sirve para los siguientes modelos
10
Otros manuales de Hardware de red de TIBCO
Manuales populares de Hardware de red de otras marcas

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manual de usuario

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manual de usuario

Yudor
Yudor YDS-16 Manual de usuario

D-Link
D-Link ShareCenter DNS-320L Manual de usuario

Samsung
Samsung ES1642dc Instrucciones de uso

Honeywell Home
Honeywell Home LTEM-PV Instrucciones de montaje