ENGLISH
Technical data
Safety instructions
First configuration
Package checklist
- Audiofy P1 / Audiofy P4
- Power cable
- Terminal connector for speakers and bus
- Installation Sheet
- Rack mounting brackets
- Brackets mounting brackets
- Nr. 8 screws (M4x10) for brackets
- Screws and caged nuts for rack mounting
ThinKnx Audiofy must be installed in compliance with
electrical installation rules of your country.The device must
be installed in a dust free place, not subject to water infiltration
and must not be placed near a source of heat or in direct contact
with the sun.
To reduce the risk of electric shock, this product
should only be opened by an authorized
technician when service is required.
- Use only the provided screws (not longer than 10 mm) to
fix the brackets to the device.
- Not attending to these safety instructions might cause fatal
accidents, injuries and damages to persons and properties.
The manufacturer / supplier assumes no liability for damages
caused by failure to comply with the intended use.
Disclaimer
The WEEE logo means that this device
contains electronic parts and it must be
discarded properly.
Power input
Property name
Power consumption
Operating temperature/humidity
Cooling
Mounting
Enclosure type
Frequency response
THD + Noise
Rackmount device measurements
Brackets mount device measurements
Package measurements
Pre-amplified outputs
-20 dB to 80 dB
Audiofy P1 Audiofy P4
200W Max
Rackmount, Brackets mount
Metal
20 Hz to 20 KHz
0.03% @ 1 KHz at nominal level
480 x 205 x 43 mm
440 x 205 x 43 mm
510 x 300 x 65 mm
Output volume range
4
Amplified outputs 4
Power for each output 50 watts stereo @ 4 ohms
Speaker impedance 4 to 16 ohms
Inputs 5 analog + 1 internal player 2 analog + 4 internal players
Input gain adjustment 0 dB to 20 dB
Analog input impedance > 10 K ohms
100-250 VAC
0
°
C to +45
°
C/ 10 % to 90% noncondensing
Convection, no vents
First connection
For the first connection of the device it is necessary to connect
power supply, outputs and ethernet cables. Connecting the
analog inputs and KNX cable is optional, connect them if you
are going to use them.
The first configuration of the device is via web console.To reach web console, an internet browser
must be used (Firefox or Chrome is recommended). Please write the following address into browser:
http://<ip address>:5051 where «ip address» is the device one.At first login use following
credentials:
User:service
Password:password
To find the IP address of the device, a search utility is available and can be downloaded from:
www.thinknx.com.
The server is configured to use DHCP. If DHCP fails, the device will acquire the following address by
default: 192.168.0.200.
If a static IP address has been set, the device is always reachable at the address: 192.168.24.254
(with subnet mask 255.255.254.254).
ThinKnx Audiofy deve essere installato secondo le disposizioni
nazionali che regolano l’installazione di materiale elettrico.
Il dispositivo deve essere installato in un luogo non polveroso,
non soggetto ad infiltrazioni d’acqua, lontano da fonti di calore e non
a contatto diretto con il sole..
Per ridurre il rischio di scariche elettriche,
in caso di assistenza, questo prodotto deve
essere aperto solo da un tecnico autorizzato.