NOTE: PLEASE NOTE THAT YOUR COOKER HOOD CAN BE USED EITHER IN
RECIRCULATION MODE OR IN EXTRACTION MODE. TO USE THE HOOD IN RE-
CIRCULATION MODE, YOU WILL NEED TO FIT THE CARBON FILTER.
IF YOU WANT TO USE YOUR COOKER HOOD IN EXTRACTOR MODE, YOU WILL
NEED TO FIT DUCTING (DIAMETER OF 125MM) TO THE SPIGOT (SEE
INSTALLATION DIAGRAM) AND WORK IT THROUGH A HOLE OF 130MM SO THAT IT
IS EXPELLING FUMES THROUGH A DEDICATED FLUE SYSTEM THAT ISN’T
COMBINED WITH OTHER EXHAUSTS.
o
Any installation work must be
carried out by a qualified
electrician or competent person.
o
The hood must be installed in
accordance with the installation
instructions and all measurements
followed.
oIf the cooker hood is installed for use
above a gas appliance then the provision for
ventilation must be in accordance with the
Australian Standard AS 5601.
oIt is dangerous to alter the
specifications or to modify this
product in any way. Do not tamper
with it or attempt to alter it in the
attempt to customise it further.
oWhen installing the hood,
ensure that the following
recommended distances are being
observed between the cooker top
and the bottom of the cooker hood:
Electric cookers:
700 mm
Gas cookers:
700 mm
Coal/ oil cookers:
800 mm
* NOTE -
DO NOT SET YOUR
COOKER HOOD LESS THAN
600 mm ABOVE YOUR
COOKER!
oWhen installed between
adjoining wall cabinets,
the cabinets must not
overhang the hob and
their undersides must be
at least 50 mm off from
the hob edges.
oThe edges of the cooker
hood are sharp –be
mindful of this as you
handle your appliance,
especially during
installation and cleaning.
DO NOT CLEAN IN
BEHIND THE GREASE
FILTERS!
oIf the room where the
cooker hood is to be used
contains a fuel burning
appliance such as a
central heating boiler
then its flue must be of
the sealed or balanced
flue type.
oIf other types of flue or
appliances are fitted,
ensure that there is an
adequate supply of air in
the room.
oWhen the hood is being
used in its extractor
Important Safety Information: Please Read this before installing & using.