1. INDEX
2. GENERAL
2.1 GENERAL INSTRUCTIONS 3
2.2 OPERATING & INSTALLING CONDITIONS 3
2.3 SYMBOLS USED 4
2.4 WARRANTY DETAILS 5
2.5 PRODUCT FEEDBACK 5
3. TECHNICAL DESCRIPTION
3.1 INTENDED USE 6
3.2 REASONABLY FORSEEABLE MISUSE 6
3.3 SYSTEM COMPONENTS 7
3.4 WIND TURBINE COMPONENTS 8
4. PARAMETER & DIMENSIONS
4.1 PARAMETER & DIMENSIONAL DETAILS 9
4.2 POWER CURVE 10
4.3 GENERAL ARRANGEMENT 11
5. CHARGE CONTROLLER
5.1 TECHNICAL DETAILS 12
5.2 WIRING DIAGRAM 13
5.3 STORAGE & OPERATION 16
6. SAFETY INFORMATION
6.1 MODIFICATIONS BY THE USER 17
6.2 RESIDUAL RISKS 17
6.3 PERSONNEL REQUIREMENTS 17
6.4 IMPORTANT SAFETY INSTRUCTIONS 18
7. PRE-USE PREPERATION
7.1 SHIPPING CONDITIONS 19
7.2 PRE-REQS AT THE PLACE OF USE 19
7.3 PERMISSIBLE WIND CLASS AND MINIMUM CLEARANCES 19
7.4 MOUNTING DETAILS 20
7.5 UNPACKING THE COMPONENTS 21
7.6 ASSEMBLING THE WIND TURBINE 21
7.7 ELECTRICAL CONNECTIONS 25
8. REGULAR OPERATION
8.1 SWITCHING ON THE WIND TURBINE SYSTEM 26
8.2 RESTART AFTER EMERGENCY 26
9. SHUTTING DOWN WIND TURBINE
9.1 EMERGENCY SHUTDOWN 27
9.2 TEMPORARY SHUTDOWN 27
9.3 AUTOMATIC BRAKE 27
10. MAINTENANCE
10.1 SAFETY PRECAUTIONS DURING MAINTENANCE 28
10.2 INSPECTION & MAINTENANCE SCHEDULE 28
10.3 MAINTENANCE & CLEANING BY THE USER 29
11. REMOVAL FROM SERVICE & DISPOSAL
11.1 FINAL DECOMISSIONING OF WIND TURBINE 30
11.2 DISPOSAL OF THE SYSTEM & COMPONENTS 30
2TESUP Electronics Ltd. All rights reserved. ©2023 | www.tesup.com
HERA WIND PRO USER MANUAL
1. Index

3TESUP Electronics Ltd. All rights reserved. ©2023 | www.tesup.com
2. General
HERA WIND PRO USER MANUAL
2.1 GENERAL INSTRUCTIONS
Before you begin installing, read this entire owner’s manual. Following the instruction and
recommendations in this manual will help assure safe and enjoyable use of your new renewable
energy system. Please take the time to read through this manual prior to assembly.
• Place this instruction manual in a safe place for reference.
• TESUP Wind Turbines can only be used with TESUP Charge Controllers and TESUP selling
Inverters.
• There has to be constant load consumption for the wind turbine system (wind turbine,
charge controller and inverter) to work smoothly without stopping and heating. That is why
we recommend grid connected systems only.
• Wind turbines, charge controllers and inverters have to be installed outdoors.
• Do not install your wind turbine on a windy or dusty day with wind speed more than 8m/s.
Wait until a calm day to install or perform maintenance on your turbine with activation of
brake.
• Listen to your turbine, if you hear any mechanical noise, maintenance may be required,
please contact your turbine dealer.
• After installation re-adjust and tighten the screws and bolts.
• Adhere to proper grounding techniques as established by the National Electrical Code.
• Your wind turbine must be installed in accordance with this manual and local and national
building code. Incorrect installation may void your warranty.
• Wind Turbine blades spin at a potentially dangerous speed, this must be respected. Never
approach a turbine in motion.
• Never open the turbine body and expose the generator unless you are instructed to do so by
a TESUP engineer. Opening the turbine body and modications to the turbine system will
void your warranty.
• Do not place your charge controller, inverter or battery under direct sunlight or close to any
heat source. Make sure to have a dry environment where there is no damp, rain, corrosion,
vibration and electromagnetic interference.
• Note wire size prior to wiring. Any under sizing of wire can be potentially dangerous.
• Check the manual brake periodically.
• Check the battery health periodically. The low battery voltage and improper connection can
cause over-spin issues.
2.2 OPERATING & INSTALLING CONDITIONS
Please make sure that:
• The wind turbine system has been erected correctly by a suitably trained person.
• All operating personnel have read and fully understood this translation of the original
instructions
• The wind turbine system is properly maintained and repaired.

2.3 SYMBOLS USED
IN THIS MANUAL:
IMPORTANT: Please take a note.
DANGER: Immediate danger can cause serious injury.
WARNING: Potential Danger, can cause Serious injury.
CAUTION: Potential Danger, can cause moderate injury.
NOTE: Useful Tips
OTHER SIGNS USED:
GENERAL WARNING
HIGH VOLTAGE
MAY START WITHOUT WARNING
ENVIORNMENTAL HAZARD
4TESUP Electronics Ltd. All rights reserved. ©2023 | www.tesup.com
2. General
HERA WIND PRO USER MANUAL

2.4 WARRANTY DETAILS
The “General Terms & Conditions of Sale and Delivery” of the manufacturer or his authorized
representative apply.
• TESUP Limited Warranty does not warrant that the operation of the Wind Turbine will be
uninterrupted, nor does this Limited Warranty guarantee specic performance or energy
production under any conditions.
• TESUP Limited Warranty does not apply to claims arising from installation of your HERA
Wind Pro Wind Turbine at improper or decient site locations as described in this user
manual. TESUP Limited Warranty does not cover any part that was not manufactured by
TESUP, nor does it cover the costs of any repairs or adjustments to your Wind Turbine that
might be needed because of the use of non-HERA Wind Pro parts, components, equipment,
or materials.
• TESUP Limited Warranty does not apply to: (i) consumable parts; (ii) cosmetic damage,
including scratches or dents unless such damage compromises the product’s function;
(iii) damage caused by overload, surges, use with any unsuitable power source, voltage
irregularities or utility system failures that enter the Wind Turbine through the output
side; (iv) damage caused by acts of God (including ood, re, earthquake, lightning, hail
damage, ying debris, wind speeds in excess of 50m/s, tornadoes, hurricanes or other
cyclonic windstorms), misuse, negligence, accident, abuse, or vandalism; (v) damage due to
a failure to service and maintainance, and/or operate the Wind Turbine in accordance with
its User Manual or provided instructions; (vi) a Wind Turbine or any of its parts that has been
modied to alter functionality or capability without the written permission of TESUP; (vii) any
Wind Turbine part whose serial number has been removed or defaced; (viii) damage or loss
to any items or products not manufactured by TESUP that are connected to, powered by, or
otherwise attached to, the Wind Turbine; (ix) any expenses incurred from travel to and from
the repair location, troubleshooting, diagnostic and repair services, equipment expenses, or;
(x) damage due to improper installation of the Wind Turbine that is not in accordance to the
user manual or, (xi) use of the wind turbine in wind regimes with an annual average of 8 m/s
or greater.
2.5 PRODUCT FEEDBACK
Please notify the manufacturer or his authorized representative about any of the following:
• Accidents
• Potential safety hazards associated with the wind turbine system
• Ambiguities in this translation of the original instructions
• Description of the wind turbine system
5TESUP Electronics Ltd. All rights reserved. ©2023 | www.tesup.com
2. General
HERA WIND PRO USER MANUAL

6TESUP Electronics Ltd. All rights reserved. ©2023 | www.tesup.com
3. Technical
Description
HERA WIND PRO USER MANUAL
3.1 INTENDED USE
• The wind turbine system may only be used as a “small wind turbine system” (SWTS) to
generate power in accordance with EN 61400-2.
• The wind turbine system may only be operated in accordance with the ratings and in the
approved wind class (refer to the technical data).
• Observance of the original instructions and compliance with the maintenance and repair
instructions are essential preconditions of use for the intended purpose.
3.2 REASONABLY FORSEEABLE MISUSE
• All forms of use which deviate from or exceed the limits of use described above are contrary
to the intended purpose. The manufacturer is not liable for any damage resulting from such
use.
• No liability will be accepted by the manufacturer if the equipment has been altered as
well as in the event of improper assembly, installation, start-up, operation, maintenance, or
repair.
• Only original parts supplied by the manufacturer are approved as spare parts or accessories.
Any spare parts or accessories not supplied by the manufacturer have not been tested
for operation and could be detrimental to reliability. No liability will be accepted by the
manufacturer for any damages which result from the use of non-approved spare parts or
accessories.
• Reasonably foreseeable misuse includes:
• Operation outside the manufacturer’s specication.
• All modications or changes to the wind turbine system without the manufacturer’s
written approval.
• Use of parts other than HERA Wind Pro original parts.
• Operation in non-approved SWTS classes.
• Operation in strong winds or hurricanes.

7TESUP Electronics Ltd. All rights reserved. ©2023 | www.tesup.com
3. Technical
Description
HERA WIND PRO USER MANUAL
3.3 SYSTEM COMPONENTS
HERA Wind Pro
CHARGE CONTROLLER
INVERTER

3.4 WIND TURBINE COMPONENTS
Top Flange (x1)
Blades (x2)
Bottom Flange (x1)
Mounting Base (x1)
Turbine Body (x1)
Rotor Shaft (x1)
8TESUP Electronics Ltd. All rights reserved. ©2023 | www.tesup.com
3. Technical
Description
HERA WIND PRO USER MANUAL

WARNING: If a hurricane scale III (50–58 m/s) or above occurs,
please cover wind turbine blades.
SPECIFICATIONS
Designation 24V to 48V (Regulated by the Charge Controller)
GENERATOR
Type 7KW vertical axis wind permanent magnet
generator
Weight 24.5kg (54lbs)
Max. Power 7kW
Operating Circuit Voltage 0-220V
Current 3-Phase
Start Of Charging 4m/s
Base Plate Material Metal
Direction Of Rotation Clockwise
Test Standards
EN 61000-6-1
(electromagnetic compatibility – immunity)
EN 61000-6-3
(electromagnetic compatibility – emissions)
ROTOR BLADES
Material Aluminium
Diameter 400 mm (1.31 Feet)
Weight Per Rotor Blades 850 g (1.87 lbs)
Direction Of Rotation Clockwise
Starting Wind Speed 4m/s (3m/s afterwards)
No. Of Blades 2
Max Rpm 950
Max Speed 50m/s
Noise 35 dB
9TESUP Electronics Ltd. All rights reserved. ©2023 | www.tesup.com
4. Parameter &
Dimensions
HERA WIND PRO USER MANUAL
4.1 PARAMETER & DIMENSIONAL DETAILS

IMPORTANT: Humidity and the ion levels in the air can impact
your turbine’s performance.
10TESUP Electronics Ltd. All rights reserved. ©2023 | www.tesup.com
4. Parameter &
Dimensions
HERA WIND PRO USER MANUAL
4.2 POWER CURVE
Tabla de contenidos
Otros manuales de turbina eólica de Tesup