Tesla TSL-SEN-GAS Manual de usuario

1
USER MANUAL
TESLA SMART
SENSOR GAS
EN
SK
SL
HR
DE
PL
UA
RU
CZ
HU

2
Packing List
After you unpack the product package, check whether the
product is intact and that all accessories are included and
complete. The following figures show the items that should
be contained in the product package.
combustible gas detector 3M sticker x1
power adapter x1 QC PASS certificate x1
QC PASS
Two expansion tubes and
two screws
User manual x1

3
Product Description
Status indicator
Short Press: simulation test.
Long Press: Rest/Network setting
Buzzer
Air exchange
window
Power port
Air intake vent
Mounting base
Indicator and Buzzer States
Red LED flashes. The buzzer beeps. Gas leakage alarm.
Yellow LED flashes. The buzzer does not beep. Detector preheats.
Green LED is on. The buzzer does not beep. Working properly.
Yellow LED flashes. The buzzer beeps. -Sound. Internal problem.
Red LED flashes. Buzzer beeps for eight times. In simulation testing status.
Green LED flashes quickly. The buzzer does not beep. In network setting.

4
Network Setting
1.After power on, the detector will preheat for 1-3 minutes,
yellow LED flashes.
2. Press the reset button for 5S and release, the green LED
will flash for network setting.
• Network access status: Press the button for 5-10 seconds
to join a network. After pressed, the red indicator is steady
on, after 5 seconds release the button, the green indicator
flashes rapidly to start distribution of the network. If the
network access is successful, the green LED remains on for
5 seconds, the green light is always on, and the alarm enters
the normal monitoring state.
• If the product fails to enter the network configuration
mode within 60s, the status indicator will be steady yellow
for 5s and then off.
Connect the product to the power supply.
Press and hold
the button for 5s.

5
Installation Instructions
1. Precautions
(1) Install the product indoors where devices use combusti-
ble gas (methane).
(2) Do not install the product outdoors.
(3) Ensure that the temperature of the installation envi-
ronment is within the range of 0°C to +55°C.
(4) Do not install the product in places where the product
will be affected by heat, steam, or smoke residual generated
by gas appliances (for example, above a gas stove).
(5) Ensure that there are no obstacles between the product
and gas devices, or the product may fail to detect gas
leakage.
(6) Do not install the product in places with a large airflow,
such as air intake vents, ventilators, windows, and doors, or
the product may fail to detect gas leakage.
(7) Ensure that the product is properly connected to a
power socket and that the power socket has power.
(8) You are advised to use screws to install the product. If
you use a 3M sticker to install the product, any product
damage or safety accidents incurred therefrom will be your
responsibility. However, if you choose to use a 3M sticker,
affix the product to a smooth, even, dry, and clean surface.
(9) Regularly check whether the product is attached to the
surface securely to prevent it from falling down.

6
90
2. Installation positions
Ceiling mount: Install the product in the annular zone about
1.5 m to 3 m above the gas source.
Wall mount: Install the product on a wall, about 0.2 m
to 0.6 m below the ceiling and 1.5 m away from the gas
source.

7
3. Installation methods
3M
3M
(1) Using screws
Use screws to fix the mounting
base to the ceiling or wall.
(2) Using a 3M sticker
Rotate the product clockwise
into the mounting base.
Affix the 3M sticker to the rear
of the mounting base. Affix the product to the target
position.

8
Using this Product
1. Preheating state
The product enters the preheating state after being powe-
red on. During the preheating period, the status indicator
is flashing yellow lights. After preheating is completed (no
more than 3 minutes), the status indicator will become
steady green.
2. Working state
When the product is working properly, the status indicator
will be steady green with no alarm sound.
3. Alarm state
If the product is working properly and the gas concentration
is higher than the preset alarm threshold, Red indicator is
flashing and the buzzer will generate an audible alarm.
4. Trouble Status
When detector is in trouble, yellow LED flashes, buzzer
beeps every 6-10s.
5. Simulation test
When the product is working, press the mute/self-diagnos-
tic button to enter the simulation test mode. After entering
the simulation test mode, the product will send a wireless
alarm signal. After the test is completed, the product will
send a wireless alarm clearance signal.
Routine Maintenance and Protection
To ensure that the product works properly, maintain and
protect the product as follows:
1. Correctly install, operate, and maintain the product in
accordance with the user manual.
2. Perform a self-diagnostic test on the product every

9
month. When the product is working, press the mute/
self-diagnostic button and ensure that the product can
generate an audible and visual alarm.
3. Once every three months, use a slightly damp towel to
clean the product cover and remove dust and oil stains
from the air intake vent of the product to ensure smooth
airflow and a normal alarm sound. Do not use a wet towel
or chemical solvents, such as alcohol or acetone to clean
the product.
4. Calibrate the product annually. Only qualified institutions
with standard gas and calibration tools are authorized to
calibrate the product.
Handling Gas Leakage
When the combustible gas concentration in the air reaches
or exceeds the preset alarm threshold, the product will
enter the alarm state. Handle the problem as follows:
1. Close the gas pipeline valve immediately.
2. Open doors and windows for ventilation.
3. Extinguish all sources of fire such as cigarette lighters,
matches, and gas burners, and do not use items that may
generate fire or any kind of electrical spark, such as electro-
nic ignition devices for water heaters or gas burners.
4. Do not turn any home appliances on or off.
5. Check the causes of the gas leakage and notify relevant
departments and professional personnel of handling the
problem.

10
Troubleshooting
Troubles: Always in preheating status when powered on.
(yellow indicator is flashing) | Yellow indicator flashes,
buzzer beeps “DI”.
Trouble Analysis: 1. Long time no powered on. 2. There is
combustible gas in the environment during the preheating
period. | Detector is defected.
Solution: 1. Power on the product for 24 hours. 2. Eliminate
combustible gas, and then power on the product to pre-
heat. | Contact the vendor for repairing.
Other Precautions
1. The product can only be used for pipeline natural gas
(methane) and cannot be used for bottled liquefied gas
(LPG).
2. Do not change the internal structure of the product.
3. Do not directly use high-concentration combustible gas,
for example, butane lighter gas or pure natural gas on the
product. The sensitivity of the product‘s detector will be re-
duced, and the product may even become non-functional.
4. Do not use a large amount of hair spray, pesticides, paint,
adhesives, or thinners near the product to avoid false alarms
and maintain the product‘s lifespan.
5. Typically, the product‘s built-in sensor can be used for
five years. Maintain the sensor or replace the product after
having using the product for five years.
6. Periodically check whether the product is working
properly. If the product is faulty, contact the vendor and
describe the fault symptoms to rectify the fault. Do not disa-
ssemble the product yourself. After-sales service engineers