Tesla BP100 Manual de usuario

1
USER MANUAL
TESLA BREAST
PUMP BP100
EN
CZ
SK
PL
HU
SL
DE

2
DESCRIPTION
1. Dust cap
2. Massage cushion
3. Pump body
4. Silicone diaphragm
5. Cap
6. Silicone tube
7. Silicone valve
8. Feeding bottle
9. Bottle cap with nipple
10. Pump motor
11. Power adaptor

3
MOTOR UNIT
ASSEMBLY INSTRUCTIONS
a. On/off
b. Change mode
c. Increase level
d. Decrease level
1. Insert the valve (7) into the
pump from below. Push it all the
way.
2. Screw the feeding bottle
(8) into the pump body (3) and
tighten.
Before the first use, all components of the breast pump should be cleaned
and disinfected in accordance with the chapter „Cleaning and disinfec-
tion“. All components need to be cleaned after each use and all compo-
nents must be disinfected before each use. Please wash hands thoroughly
before touching the cleaned components.

4
3. Insert the diaphragm (4) into
the top part of the pump body
(3). Press the diaphragm down to
ensure it is stable.
4. Attach the cap (5) to the pump
body (3). Connect one end of the
tube (6) to the cap connector and the
other end to the pump motor (10).
5. Insert the massage cushion (2) into the pump body (3). Press it down to
ensure it fits properly. Connect the power adapter to the motor.

5
OPERATION INSTRUCTIONS
PUMPING PROCEDURE INSTRUCTIONS
CLEANING AND DISINFECTION
1. Press the ON/OFF button (starts in „stimulation“ mode automatically)
2. Press the mode button (switch between „massage“ - „stimulation“ -
„suction“ modes)
3. Massage mode (9 levels)
4. Stimulation mode (9 levels)
5. Suction mode (9 levels)
Each click on the „13“ and „14“ buttons will display the current level.
6. Working time of the pump is 30 minutes. After 30 minutes, the pump
will shut down automatically.
7. The feeding bottle should not be overfilled. Please follow indication line.
8. 2 hours of charging will provide 90 minutes of working time.
1. Wash hands thoroughly and ensure that your breast is clean. Relax and
sit comfortably.
2. Place the breast into the pump, make sure the nipple is in the center.
3. Press “11“ button to turn on the pump. Press “12“ button to cycle
between modes.
White - “massage“ mode
Yellow - “stimulation“ mode
Blue - “suction“ mode
Press “13“ and “14“ buttons to increase/decrease power to match your
comfort.
Note: You don‘t need to use the maximum suction, choose the suction
that makes you feel comfortable.
4. After pumping, turn off the breast pump, and then carefully remove the
breast from the breast pump.
5. Unscrew the feeding bottle from the breast pump to prepare for nursing
or storage. To clean the used breast pump components, follow instruction
in chapter „Cleaning and disinfection“.
Warning! The motor unit should only be wiped down with a damp cloth.
Never wash the motor unit.
„Before first use, clean and disinfect all parts of the pump. Wash all the
parts every time before use. The breast pump must be disassembled
before every cleaning.

6
Be careful when removing and cleaning the silicone valve “7“. If the valve
is damaged, the breast pump will not work properly. To remove the valve,
gently pull the sides of the valve. Clean all the components with hot water
and a little dish washing soap and rinse thoroughly. To clean the valve, rub
it gently, using warm water and dish washing soap. Do not insert any ob-
ject into the valve, it might lead to damage. Alternatively, the components
can be washed in the dishwasher. Place the parts in upper basket. Disinfect
all the components except the by sterilizing for 5 minutes.
STORAGE AND HEATING OF BREAST MILK
Breast milk storage
After the breast milk is collected, close the container cover tightly or seal
the storage bag, the milk must be put into the refrigerator immediately and
can be refrigerated or frozen. Milk can be refrigerated for 3 days or frozen
for 6-12 months. Never refreeze breast milk. Do not add fresh breast milk
into frozen milk.
Breast milk heating
Use the milk/food warmer or warm water to thaw breast milk. Never use a
microwave or boiling water to heat breast milk.
Attention
1. If you are freezing the breast milk, fill the container only to approxima-
tely two thirds of the capacity to leave space for volume expansion when
freezing.
2. Don‘t place breast milk in the refrigerator door to avoid temperature
fluctuations.
3. Gently shake the bottle to mix the contents.
5. Do not heat the frozen breast milk in a microwave or boiling water to
avoid loss of nutrition and scalding.
Warning
This is a personal product, do not share it to avoiding health risks. When
removing or connecting parts, operate carefully, do not overexert to avoid
damage. This product should not be exposed to sun and should be kept
away from children.

7
TROUBLESHOOTING
Lack suction power
Check whether the breast pump components are correctly assembled and
the valve is not damaged. Make sure the massage cushion „2“, silicone
diaphragm „3“ are firmly attached to the pump body to achieve ideal seal.
Unable to collect milk
Check the suction with your hand. Check the assembly of the pump. Try to
relax when pumping. Repeat attempts with different settings.
Breast pain when pumping
Pain may be caused by excessive sucking force. You do not need to use
the most powerful setting. Start over and try to find comfortable lower
setting. You can also consult breast feeding specialist.

8
EU DECLARATION OF CONFORMITY
Hereby, Tesla Global Llimited declares that the radio equipment type TSL-PC-BP100
is in compliance with Directive 2014/53/EU. The full text of the EU declaration of
conformity is available at the following internet address: tsl.sh/doc
Manufacturer
Tesla Global Limited
Far East Consortium Building
121 Des Voeux Road Central
Hong Kong
www.teslasmart.com
INFORMATION ABOUT DISPOSAL AND RECYCLING
This product is marked with the symbol for separate collection. The product must be
disposed of in accordance with the regulations for disposal of electrical and electronic
equipment (Directive 2012/19/EU on waste electrical and electronic equipment).
Disposal together with regular municipal waste is prohibited. Dispose of all electrical
and electronic products in accordance with all local and European regulations at the
designated collection points which hold the appropriate authorisation and certification
in line with the local and legislative regulations. Correct disposal and recycling help
to minimise impacts on the environment and human health. Further information
regarding disposal can be obtained from the vendor, authorised service centre or local
authorities.

9
BENUTZERHANDBUCH
TESLA BREAST
PUMP BP100
EN
CZ
SK
PL
HU
SL
DE

10
BESCHREIBUNG
1. Staubschutzkappe
2. Massageaufsatz
3. Pumpenkörper
4. Silikonmembran
5. Kappe
6. Silikonschlauch
7. Silikonventil
8. Saugflasche
9. Flaschenverschluß mit Nippel
10. Pumpenmotor
11. Netzadapter
Tabla de contenidos
Idiomas: