3
EN: OUTDOOR GAS HEATER | User Manual
Purchase LPG tanks only with these required measurements: (31.8cm) (diameter) x 58cm)
(tall) with 15kg capacity maximum. -In case of violent wind particular attention must be taken
against tilting of the appliance;
- The injector in this appliance is not removable and the injector is only assembled by
manufacture. This appliance is forbidden to convert from one gas pressure to another
pressure.
- Do not connect the gas cylinder directly to the appliance without regulator. Use only the
type of gas and the type of cylinder specied in the instructions.
A regulator(compliees with EN16129:2013 and the national regulation) of the correct pressure
corresponding to the appliance category. - with 30mbar max pressure.
Use 30mbar regulator for butane/propane under the category 13B/P(30).
It‘s recommended to use exible hose that approved by EN16436: 2014. with length no more
than 1.5m
CAUTION
PLEASE READ CAREFULLY THE FOLLOWING SAFETY GUIDELINES BEFORE OPERATION.
• Do not use the patio heater for indoors, as it may cause personal injury or property damage.
• This outdoor heater is not intended to be installed on recreational vehicles and/or boats.
• Installation and repair should be done by a qualied service person.
• Improper installation, adjustment, alteration can cause personal injury or property damage.
• Do not attempt to alter the unit in any manner.
• Never replace or substitute the regulator with any regulator other than the factory-
suggested replacement.
• Do not store or use gasoline or other ammable vapors or liquids in the heater unit.
• The whole gas system, hose, regulator, pilot or burner should be inspected for leaks or
damage before use, and at least annually by a qualied service person.
• All leak tests should be done with a soap solution. Never use an open ame to check for
leaks.
• Do not use the heater until all connections have been leak tested.
• Turn o the gas valve immediately if smell of gas is detected. Turn Cylinder Valve OFF. If
leak is at Hose/ Regulator connection: tighten connection and perform another leak test.
If bubbles continue appearing should be returned to hose‘s place of purchase. If leak is at
Regulator/Cylinder Valve connection: disconnect, reconnect, and perform another leak check.
If you continue to see bubbles after several attempts, cylinder valve is defective and should be
returned to cylinder‘s place of purchase.
• Do not transport heater while it‘s operating.
• Do not move the heater after it has been turned o until the temperature has cooled down.
• Keep the ventilation opening of the cylinder enclosure free and clear of debris.