For versions with mounted Ex db eb adapter (PLFM ...- 2) there are specific conditions of use:
- the user must ensure adequate fastening of the cable outside the cable gland because the cable gland of the multi-core
conductor insulator with a connection chamber has been tested with a lower pulling force in accordance with p. A.3.1.1 of
EN IEC 60079-0,
- the device must be installed in places with a lower risk of impact because the multi-core conductive insulator with a
connection chamber has been tested with a lower impact energy in accordance with EN IEC 60079-0.
Threaded joints:
- M125x1,5 - 6H / 6g, medium tolerance according to ISO 965-3, thread DIN 13 T.24, 11 full threads,
- M20x1,5 - 6H / 6g, medium tolerance according to ISO 965-3, thread DIN 13 T.24, 7 full threads.
For luminaires type PLFM 100 / 1-3 (versions with direct entry) it is necessary to use a cable with a temperature resistance not
less than 90 ° C. For luminaires type PLFM 70 HSE-3 (version with direct introduction) it is necessary to use a cable with a
temperature resistance not less than 140 ° C.
6. TYPE
PLFM ... - .
basic type code
maximal wattage and type of sources:
-100 - A incandescent lamp 100W max,
-A ECO halogen lamp 105W max,
-QT halogen lamp 100W max.
-100/1 - LME mixed discharge lamp 100W max.
-100/2 - TC-SB compact fluorescent lamp 23W max.
-100/3 - LED BULB lamp 15W max.
-20 LED - LED MODUL special 20W max.
-FLASH - XENON MODUL special 5W max.
-70 HSE - HSE-I high pressure sodium discharge lamp 70W,
-HSE-I high pressure sodium discharge lamp 50W.
-LUXOMAT 10 –light switch 10A,
-LUXOMAT 16 –light switch 16A.
Type of entries:
-1 –indirect entry –type with Ex eb junction box,
-2 –indirect entry –type with Ex db adapter ADP 23/1,
-3 –direct entry –type with Ex db cable gland.