Teledyne OT-3 Manual de usuario

Trace Oxygen Analyzer
Teledyne Analytical Instruments i
OPERATING INSTRUCTIONS FOR
MODEL OT-3MODEL OT-3
Trace Oxygen Analyzer
DANGER
Toxic gases and or flammable liquids may be present in this monitoring system.
Personal protective equipment may be required when servicing this instrument.
Hazardous voltages exist on certain components internally which may persist
for a time even after the power is turned off and disconnected.
Only authorized personnel should conduct maintenance and/or servicing.
Before conducting any maintenance or servicing, consult with authorized
supervisor/manager.
P/N M74173
10/28/2001
ECO#

Model OT-3
Teledyne Analytical Instruments ii
Copyright © 2000 Teledyne Analytical Instruments
All Rights Reserved. No part of this manual may be reproduced, transmitted, transcribed,
stored in a retrieval system, or translated into any other language or computer language in
whole or in part, in any form or by any means, whether it be electronic, mechanical,
magnetic, optical, manual, or otherwise, without the prior written consent of Teledyne
Analytical Instruments, 16830 Chestnut Street, City of Industry, CA 91749-1580.
Warranty
This equipment is sold subject to the mutual agreement that it is warranted by us free from
defects of material and of construction, and that our liability shall be limited to replacing or
repairing at our factory (without charge, except for transportation), or at customer plant at
our option, any material or construction in which defects become apparent within one year
from the date of shipment, except in cases where quotations or acknowledgements provide
for a shorter period. Components manufactured by others bear the warranty of their
manufacturer. This warranty does not cover defects caused by wear, accident, misuse,
neglect or repairs other than those performed by Teledyne or an authorized service center.
We assume no liability for direct or indirect damages of any kind and the purchaser by the
acceptance of the equipment will assume all liability for any damage which may result from
its use or misuse.
We reserve the right to employ any suitable material in the manufacture of our apparatus,
and to make any alterations in the dimensions, shape or weight of any parts, in so far as
such alterations do not adversely affect our warranty.
Important Notice
This instrument provides measurement readings to its user, and serves as a tool by which
valuable data can be gathered. The information provided by the instrument may assist the user
in eliminating potential hazards caused by his process; however, it is essential that all
personnel involved in the use of the instrument or its interface, with the process being
measured, be properly trained in the process itself, as well as all instrumentation related to it.
The safety of personnel is ultimately the responsibility of those who control process
conditions. While this instrument may be able to provide early warning of imminent
danger, it has no control over process conditions, and it can be misused. In particular, any
alarm or control systems installed must be tested and understood, both as to how they
operate and as to how they can be defeated. Any safeguards required such as locks, labels,
or redundancy, must be provided by the user or specifically requested of Teledyne at the
time the order is placed.
Therefore, the purchaser must be aware of the hazardous process conditions. The purchaser
is responsible for the training of personnel, for providing hazard warning methods and
instrumentation per the appropriate standards, and for ensuring that hazard warning devices
and instrumentation are maintained and operated properly.
Teledyne Analytical Instruments, the manufacturer of this instrument, cannot accept
responsibility for conditions beyond its knowledge and control. No statement expressed or
implied by this document or any information disseminated by the manufacturer or its
agents, is to be construed as a warranty of adequate safety control under the user’s process
conditions.

Trace Oxygen Analyzer
Teledyne Analytical Instruments iii
Specific Model Information
The instrument for which this manual was supplied may
incorporate one or more options not supplied in the standard instrument.
Commonly available options are listed below, with check boxes. Any
that are incorporated in the instrument for which this manual is supplied
are indicated by a check mark in the box.
Instrument Serial Number: _______________________

Model OT-3
Teledyne Analytical Instruments iv
Important Notice
Model OT-3 complies with all of the requirements of the
Commonwealth of Europe (CE) for Radio Frequency Interference,
Electromagnetic Interference (RFI/EMI), and Low Voltage Directive
(LVD).
The following International Symbols are used throughout the
Instruction Manual for your visual and immediate warnings and when
you have to attend CAUTION while operating the instrument:
STAND-BY: Instrument is on Stand-by, but circuit is
active
GROUND: Protective Earth
CAUTION: The operator needs to refer to the manual
for further information. Failure to do so may
compromise the safe operation of the equipment.
CAUTION: Risk of Electrical Shock
Note: Additional information in the form of notes are
included which emphasize specific topics regarding the
present discussion.
No
Symbol

Trace Oxygen Analyzer
Teledyne Analytical Instruments v
This instrument is designed for CL1 DIV II hazardous locations. It
is the customer's responsibility to ensure safety especially when
combustible gases are being analyzed since the potential of gas
leaks always exist.
The customer should ensure that the principles of operating this
equipment are well understood by the user. Misuse of this product in
any manner, tampering with its components, or unauthorized
substitution of any component may adversely affect the safety of this
instrument.
Since the use of this instrument is beyond the control of Teledyne, no
responsibility by Teledyne, its affiliates, and agents for damage or
injury from misuse or neglect of this equipment is implied or assumed.
CAUTION: THE ANALYZER SHOULD ONLY BE USED FOR THE
PURPOSE AND IN THE MANNER DESCRIBED IN
THIS MANUAL.
IF YOU USE THE ANALYZER IN A MANNER OTHER
THAN THAT FOR WHICH IT WAS INTENDED,
UNPREDICTABLE BEHAVIOR COULD RESULT
POSSIBLY ACCOMPANIED WITH HAZARDOUS
CONSEQUENCES.
This manual provides information designed to guide you through
the installation, calibration and operation of your new analyzer. Please
read this manual and keep it available.
Occasionally, some instruments are customized for a particular
application or features and/or options added per customer requests.
Please check the front of this manual for any additional information in
the form of an Addendum which discusses specific information,
procedures, cautions and warnings that may be peculiar to your
instrument.
Manuals do get lost. Additional manuals can be obtained from
Teledyne at the address given in the Appendix. Some of our manuals are
available in electronic form via the internet. Please visit our website at:
www.teledyne-ai.com.

Model OT-3
Teledyne Analytical Instruments vi
Table of Contents
List of Figures.............................................................................viii
Introduction....................................................................................1
1.1 Overview 1
1.2 Main Features of the Analyzer 1
1.3 Front Panel Description 2
1.4 Rear Panel Description 4
Operational Theory........................................................................6
2.1 Introduction 6
2.2 Micro-fuel Cell Sensor 6
2.2.1 Principles of Operation 6
2.2.2 Anatomy of a Micro-fuel Cell 7
2.2.3 Electrochemical Reactions 8
2.2.4 The Effect of Pressure 9
2.2.5 Calibration Characteristics 9
2.3 Electronics 10
2.3.1 General 10
2.3.2 Signal Processing 11
Installation ...................................................................................13
3.1 Unpacking the Analyzer 13
3.2 Location and Mounting 14
3.2.2 Installing the Micro-fuel Cell 14
3.3 Electrical Connections 14
3.3.1 Primary Input Power 15
3.3.2 Analog Outputs 15
3.3.3 Alarm Relays 16
3.3.4 Relay Ratings 17
3.3.5 Solid State Relay Output 18

Trace Oxygen Analyzer
Teledyne Analytical Instruments vii
3.4 Gas Connections 18
3.5 Sample System 20
3.6 Installation Checklist 21
Operation......................................................................................23
4.1 Introduction 23
4.2 Using the Function and Data Entry Buttons 24
4.3 Setting the Analysis Ranges 24
4.3.1 HI Range 25
4.3.2 LO Range 25
4.4 Setting the Alarm Setpoints 25
4.4.1 Set Alarm 1 25
4.4.2 Set Alarm 2 26
4.4.3 Power Failure Alarm 26
4.5 Alarm Delay 26
4.6 Keypad Lockout 27
4.7 Selecting a Fixed Range or Autoranging 28
4.8 Calibration 28
4.9 Displaying Percent & PPM on the LED Display 29
4.10 Supplementary Information 29
Maintenance.................................................................................31
5.1 Replacing the Fuse 31
5.2 Sensor Installation or Replacement 32
5.2.1 When to Replace a Sensor 32
5.2.2 Ordering and Handling of Spare Sensors 33
5.2.3 Removing the Micro-fuel Cell 33
5.2.4 Installing a Micro-fuel Cell 34
5.2.5 Cell Warranty Conditions 35
Appendix ......................................................................................36
A.1 Specifications 36
A.2 Spare Parts List 37
A.3 Reference Drawing 38
A.4 Miscellaneous 38

Model OT-3
Teledyne Analytical Instruments viii
List of Figures
Figure 1-1: Front Panel...................................................................3
Figure 1-2: Rear Panel (AC Version)..............................................5
Figure 1-3: Rear Panel (DC Version)..............................................5
Figure 2-1: Cross Section of a Micro-fuel Cell................................7
Figure 2-2: Characteristic MFC Input/Output Curve .....................10
Figure 2-3: Block Diagram of the Signal Processing Electronics..11
Figure 3-1: Electrical Connectors for AC Control Unit ..................15
Figure 3-2: Contact ID for FAILSAFE Relay Operation ..............166
Figure 3-3: Gas Connections.........................................................19
Figure 3-4: OT-3 Sample System.................................................21
Figure 4-1: Front Panel Control and Indicators.............................23
Figure 5-1: AC Fuse Replacement...............................................32

Trace Oxygen Analyzer Introduction
Teledyne Analytical Instruments 1
Introduction
1.1 Overview
The Teledyne Electronic Technologies Analytical Instruments
(TET/AI) Model OT-3 is a microprocessor-based trace oxygen analyzer
for real-time measurement of the parts per million of oxygen in inert
gases, or in a wide variety of gas mixtures. It features simple operation,
fast response, and a compact, rugged construction. Typical applications
of the Model OT-3 include monitoring natural gas pipelines, wellheads,
and compressor/blowers.
1.2 Main Features of the Analyzer
•The main features of the analyzer include:
•Insta-Trace sensor technology
•Stainless steel sample system (with PVC scrubber and
Nylon cell block)
•Pressure regulator
•Coalescing filter
•Acid gas scrubber (clear, rebuildable )
•Flow control restrictor
•Sample shut off valve
•Bypass/filter drain valve
•Flowmeter
•Viewing window
•Sample/Span selector valve
•NEMA 4 enclosure (15.8” x 11.8” x 8.1”).
•Viewing window 3300/OT-3 Control Unit

Introduction OT-3
Teledyne Analytical Instruments 2
The Model 3300/OT-3 Control Unit has its own long list of features
including:
•Keypad lockout feature
•Two user settable fail-safe alarms (with a user settable 0-20
min. time delay )
•Two user settable ranges (from 0-10PPM – 0-9999PPM)
with user selectable auto-ranging.
•Power fail alarm
•SSR power output (Solid State Relay power available on AC
control units)
•Micro processor based electronics 8 bit ADC & 18 bit DAC
•Large 3 ½ digit LED O2 concentration read-out
•7 button user interface keypad
•Alarm condition indicator LED
•100-240 VAC 50/60 Hz power (optional 9-36VDC )
•0-10 VDC output
•4-20 mA output
•0-10 VDC range ID output
•Electronic temperature compensation
•Optional RS323 interface
•Accuracy: +/- 2% of range (at constant temp.)
•Response time: 90% in 65 sec of less @ 25 degrees C
•Temperature range (0-50 degrees C)
1.3 Front Panel Description
All controls are accessible from the front panel. See Figure 1-1.
The front panel has seven push-button membrane switches, a digital
meter, and an alarm indicator LED for operating the analyzer. These
features are described briefly here and in greater detail in Chapter 4,
Operation.
Tabla de contenidos
Otros manuales de Equipo de oxígeno de Teledyne

Teledyne
Teledyne MX300-I Manual de usuario

Teledyne
Teledyne 356WA Manual de usuario

Teledyne
Teledyne MX300-I Manual de usuario

Teledyne
Teledyne 3020T Manual de usuario

Teledyne
Teledyne 319R Manual de usuario

Teledyne
Teledyne 3160 Manual de usuario

Teledyne
Teledyne 329R Manual de usuario

Teledyne
Teledyne MD300 Manual de usuario

Teledyne
Teledyne MX300 Manual de usuario