TELCARE BGM Manual de usuario

Telcare®Blood Glucose Monitoring System ®
TelcareBlood Glucose
Monitoring System
User Manual
Thank you for choosing the
Telcare Blood Glucose Monitoring System.
The Telcare system is comprised of the
Telcare meter and the online website.
The meter provides accurate readings sent immediately to your online
account to store, track and chart. Personalized messages are also sent
from www.mytelcare.com to the meter.
This manual will provide you with all you need to know to use
your new meter. So let’s get started.
*Not intended for sale within the EU.
(All images are for reference only.)

Telcare®Blood Glucose Monitoring System
®
The Telcare Blood Glucose Monitoring system is intended for the
quantitative measurement of glucose in fresh capillary whole blood
samples drawn from the ngertips, forearm, or palm. It is intended
for lay use by persons with diabetes to aid in diabetes management.
It is indicated for use at home (over the counter [OTC]) and should be
used only by a single patient and should not be shared. Test results are
plasma-calibrated for easy comparison to clinical laboratory methods.
Testing is done outside the body (in vitro diagnostic use). The Telcare
Blood Glucose Monitoring System consists of the Telcare BGM®Blood
Glucose Meter, Telcare Blood Glucose Test Strips, and Telcare Glucose
Control Solutions. The Telcare Blood Glucose Monitoring system is not
indicated for the diagnosis or screening of diabetes or for neonatal
use. Palm and forearm testing should be done only during steady-state
times when glucose is not changing rapidly. The Telcare BGM Blood
Glucose Meter uses cellular data transmission to send test results to
Telcare’s remote database, Telserve, and to receive messages from
Telserve. The Telcare Blood Glucose Monitoring System is not intended
to provide automated treatment guidance or decisions, nor is it to be
used as a substitute for professional healthcare judgment.
Intended Use
(i)

Telcare®Blood Glucose Monitoring System ®
(ii)
Your Telcare Blood Glucose Meter
Getting Started 1
The Telcare BGM®Device 2
Telcare Test Strips 3
The Display Screen 4
Setting Up Your Telcare BGM 5
Settings Options 6
Control Solution Testing
Step-by-Step Guide to Control Testing 8
Testing Your Blood Sugar
Preparation and Safety 14
Step-by-Step Blood Sugar Testing 16
Prepare Your Lancing Device 17
Understanding Your Blood Glucose Test Results 28
View Your History on the Meter or Online 29
Maintenance of Your Telcare BGM and Lancing Device
Charging Your Telcare Blood Glucose Meter 30
Cleaning and Disinfecting Your Meter 32
Cleaning and Disinfecting Your Lancing Device 34
Storing Your Telcare BGM Meter and Test Strips 36
Troubleshooting 37
Terms of Warranty 40
Specications 41
About Telcare 42
Contact Telcare 43
Display Icon Denitions Inside Back Cover
Table of Contents

Telcare®Blood Glucose Monitoring System
®
(iii)
The Telcare Blood Glucose Monitoring System and lancing device is
for single patient use. Do not share it with anyone, including family
members! Do not use on multiple patients!
Because all parts of the kit may come in contact with your blood, all
parts are considered biohazardous. Kit parts can potentially transmit
infectious diseases, even after cleaning and disinfection.
Users should wash hands thoroughly with soap and water and dry
thoroughly after handling the meter, test strips, and any lancing device.
For Cleaning and Disinfecting procedures to prevent the spread of
diseases such as Hepatitis B, see Cleaning and Disinfecting Your Meter
(page. 32).
For Technical Support, contact Telcare at (888) 666-4530 (US) or
(1) (978) 610-4688 (International).
Hours of Operation: Monday - Friday, 9AM - 9PM EST
References
“FDA Public Health Notication: Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting
Bloodborne Pathogens: Initial Communication”(2010)
http://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm224025.htm
“CDC Clinical Reminder: Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting Blood-
borne Pathogens” (2010)
http://www.cdc.gov/injectionsafety/Fingerstick-DevicesBGM.html
“Protection of Laboratory Workers from Occupationally Acquired Infections; Approved Guideline–Third Edition.
Clinical and Laboratory Standards Institute (CLSI), document M29-A3, (ISBN 1-56238-567-4).
Important Safety Instructions

Telcare®Blood Glucose Monitoring System ®
1
Unboxing the Telcare BGM®for the rst time
Before we begin, take a moment to go over the contents of your Telcare
BGM kit. Your kit should include:
nTelcare BGM (battery included)
nAC Charger
nQuick Start Guide
nInstruction Manual
nTest Strip Insert
Getting startedImportant Safety Instructions
YOUR TELCARE®BLOOD GLUCOSE METER
nControl Solution Levels 1 & 2
(2.5 mL)
nLancing Device
nTelcare Lancets (10 Count)
nTelcare Test Strips (10 Count)
Using your new meter
Make sure you charge your glucose meter for at least 3 hours before rst use.
To charge your glucose meter, use the AC Charger included in your kit.
IMPORTANT: Slight delays occur when meter powers on. If delay is greater than
20 seconds, do not use meter. Contact technical support at (888) 666-4530 (US)
or (1) (978) 610-4688 (International).
You should use the Telcare BGM for:
nTesting blood glucose
nTesting only with fresh capillary whole blood samples
You should NOT use the Telcare BGM for:
nThe diagnosis of diabetes
nTesting blood glucose on newborn infants
n Testing of arterial blood
nTesting of venous blood

Telcare®Blood Glucose Monitoring System
®
The Telcare BGM®
2
1Power Button
2UP / DOWN
Keys to scroll
through the
menus
3Enter Button
4Display Screen
5Insert Test Strip
(white side up)
6Charging Port
(do not
attempt to
insert strip
here)
7Wireless Signal
Indicator
(Other carrier
names may
appear here.)
2
6
5
7
3
4
2
1
right side
left side
bottom

Telcare®Blood Glucose Monitoring System ®
3
Telcare Test Strips
Blood Sample End
Contact End
(put into device)
Important notes on test strips:
nBecause of the autocoding feature of this meter, the strip insertion will be
snug. This is to be expected and users nd it easy after a few attempts.
nCheck the expiration date printed on the test strip bottle and its package.
Do Not use expired test strips.
nUse each test strip immediately after removing it from the bottle.
nDo not use wet or damaged test strips.
nKeep away from direct sunlight and heat. Store the test strip bottle in a dry,
cool place.
nRecord the“date opened”on the bottle label. Discard the bottle and any
remaining test strips 6 months after the date of opening.
nDo not operate the meter outside the temperature range of 50˚F (10˚C) to
104˚F (40˚C).

Telcare®Blood Glucose Monitoring System
®
The Display Screen
4
In this Display Screen, use the UP/
DOWN buttons (located on the left
of your meter) to access the meter’s
options:
nTest Mode
nL1 Control Solution Mode (Low)
nL2 Control Solution Mode (High)
nHistory
nSettings Menu
On the Display Screen, you can
see the following:
1Wireless Signal Strength
2Current Time
3Battery Level
4Last Test Reading
5Date and Time of Last Reading
3 2
1
4
5
Up button
Down button
left side

Telcare®Blood Glucose Monitoring System ®
Setting Up Your Telcare BGM®
5
Your Telcare BGM time is automatically updated with the local date and time
when a cellular connection is established.
If you would like to view your meter’s preset settings, navigate to the
Settings screen.
Getting to the Settings Screen
1 Power (PWR) your Telcare BGM device on.
2 Use the UP/DOWN buttons
to reach the Settings Screen.

Telcare®Blood Glucose Monitoring System
®
6
Settings Options
Alarms
Create up to 3 alarms to help remind yourself when to test next.
Date and Time
This page allows you to view the Date and Time settings of your device.
Volume
This page allows you to select the volume of your meter. Use the UP/DOWN
keys to select the appropriate volume. There are six possible volumes you
may select from.
Brightness
Change the brightness of your meter’s screen.
Language Settings
Change the language displayed by your meter.
BG Tag Timeout
BG tag timeout determines the duration of the tagging time before a new
blood glucose reading is automatically sent to the server if no selection
is made.
Airplane Mode
Turning on Airplane Mode disables cellular network access. You will not
be able to transmit your readings while Airplane Mode is turned on. Your
meter’s clock will continue to work properly while in this mode.
Tabla de contenidos
Otros manuales de Medidor de glucosa en sangre de TELCARE
Manuales populares de Medidor de glucosa en sangre de otras marcas

ReliOn
ReliOn Prime Manual del operador

AgaMatrix
AgaMatrix Presto Manual de usuario

Polymer Technology Systems
Polymer Technology Systems A1C Now Self Check Manual de usuario

Medisana
Medisana GlucoDock Manual de usuario

Arkray
Arkray ASSURE PLATINUM Manual de usuario

Dexcom
Dexcom G4 Professional Manual de usuario

LabStyle
LabStyle Dario Manual de usuario

ACONLABS
ACONLABS ON CALL EXPRESS Manual de usuario

Higi Technology
Higi Technology iGlucose Manual de usuario

Bayer HealthCare
Bayer HealthCare CONTOUR NEXT Manual de usuario

Accu-Chek
Accu-Chek ADVANTAGE Manual de usuario

Sanofi-aventis
Sanofi-aventis BG STAR Especificaciones técnicas