ADIR Semi –Automatic 2”-3” filters TDS
Installation and maintenance instructions
Box contents
•Main filter body –picture
1
•Flush valve 2" FF –picture 2
•Flush valve 1/2" FM –picture 3
•Pressure indicator kit –picture 4
oPressure indicator.
o6 mm tube length 20cms (long).
o6 mm tube length 15cms (short).
o2 Female threaded couplers 6 mm
o2 connectors 1/4"M to 6 mm elbow
o1 connector 1/4"F to 6 mm elbow
o1 connector 1/4"F to 6 mm adaptor
Assembly
•Connect the 2” flush valve to the bottom of the filter cup,
(no need to use Teflon, valve is self-seal).
Make sure handle open position is away from filter cup.
•Connect the ½” flush valve to the flush screen outlet, (no
need to use Teflon, valve is self-seal).
•Pressure indicator:
oConnect two 1/4"F couplers to filter body top
outlets.
Connect two elbow 1/4"M to the couplers.
oConnect elbow 1/4"F to the bottom of the
indicator.
oConnect 1/4"F adaptor to side of the indicator.
oPress fit the indicator to the slots on the filter
body.
oConnect long 20cms tube from Filter inlet port to
indicator bottom (marked "+").
oConnect long 15cms tube from Filter outlet port
to indicator side (marked "-").
oHydraulic fitting may require Teflon to seal.
•Filter is ready for installation –picture 5
Installation
•Filter can be installed in vertical position or at 90° to the
pipe, (Flush valve pointing down or to the side).
•Ensure proper flow direction as clearly marked on the
filter.
•Make sure both flush valves are closed.
•It is recommended to install a shut off valve before the
filter for maintenance.
•Filter is ready for first operation