17
7 - 9 PHOTOCELLS
N.C. photocell input - it cuts in during the closing. Bridge the connectors
if not used. (7= COM - 9= FOT)
Note: the photocell transmitter must always be supplied by termi-
nals no. 12 and no. 13, since the safety system test (phototest) is
carried out on it. Without this connection, the control unit does not
work. To override the testing of the safety system, or when the pho-
tocells are not used, set dip-switch no. 6 to OFF.
7 - 10 SENSITIVE
EDGE
SENSITIVE EDGE input (resistive sensitive edge or xed edge); It works only
during the closing phase and causes the total reopening of the boom.
Bridge the terminals if not used.
In case of an active automatic closing: After the rst intervention of the xed
edge and the consequent total opening, the boom will try an automatic
closing. If the CF contact is engaged again, the automation will reopen
up to the opening limit switch and temporarily disable the automatic
closing. It will return to normal operation only after the rst maneuver of
the automation, which requires a manual command. (7 = COMMON - 10
= SENSITIVE EDGE)
11 - 12 ** AUX auxiliary circuits output 18 V DC max. 15 W for photocells, receivers, etc...
(11= NEGATIVE - 12= POSITIVE)
12 - 13 ** TX PHOTOCELLS 18V DC output for transmitter photocell – phototest - max. no. 1 photocell
transmitters. (12 = POSITIVE - 13 = NEGATIVE)
14 - 15 **
FLASHING LIGHT
(LED CABINET
LUXE)
18V DC max. 20W output for ashing light supply, ashing signal sup-
plied by the control unit, rapid for closing, slow for opening. (14 = POSI-
TIVE - 15 = NEGATIVE)
16 - 17* ** ELECTROMAGNET
(VANDAL-PROOF)
Output for vandal-proof 18V DC, 3 W max;
Output for electromagnet to be connected to the end of the rod to hold
the barrier closed (vandal-resistant device). With the barrier closed, the
electromagnet is constantly powered. Every time a command is given,
the electromagnet is turned o before the motor starts running. (16=
POSITIVE - 17= NEGATIVE)
16 - 18* ** BAR LED (WHITE) bar LED power output. (16=POSITIVE - 18= NEGATIVE). See instructions
LA4/8 LARG 4/8
19 - 20* 2nd CH RADIO
2nd radio channel output - for control of an additional automation or for
switching on lights, etc... (N.O. clean contact)
Warning: to connect other devices to the 2nd Radio Channel (area
lighting, pumps, etc.), use an additional auxiliary relay (see note at
end of paragraph).
WARNING: the default outlet is active monostable 2 sec. To switch it
to active bistable or to modify the activation time it is necessary to
use the TAUPROG hand-held programmer (see relative instructions).
21 - 22 AERIAL plug-in radio-receiver aerial input , for 433.92 MHz receivers only. (21 =
GROUND - 22 = SIGNAL)
23 - 24 -
28 - 29 MOTOR motor supply output 18V DC max. 50 W.
(23-28 = POSITIVE - 24-29 = NEGATIVE). See note below.
25 - 26 - 27 OPTIONAL
ENCODER
encoder supply and input (25 = WHITE signal - 26 = BLUE negative - 27 =
BROWN positive). See note below.
30 - 31 - 32 MAIN
ENCODER
encoder supply and input (30 = WHITE signal - 31 = BLUE negative - 32 =
BROWN positive).
* The outlets can be congured using the TAUPROG (see relative instructions). The standard congu-
ration is shown in the table.
** If Jumper 6 is not plugged in, energy saving mode will be activated and, at the end of each
manouvre, outputs 11-12, 12-13, 14-15, 16-17 and 16-18 will be switched o.
ENGLISH