Tab R4824 Manual de usuario

www.tab.si
Lithium-Ion Phosphate Energy Storage System
R4824 Operation Manual
R4824_Operating_Manual_17.05.2021.indd 1R4824_Operating_Manual_17.05.2021.indd 1 17.5.2021 14:15:5117.5.2021 14:15:51

R4824_Operating_Manual_17.05.2021.indd 2R4824_Operating_Manual_17.05.2021.indd 2 17.5.2021 14:15:5117.5.2021 14:15:51

Contents
1. Symbol in label, manual and product 5
2. Safety Precautions 6
2.1 Before Connecting 6
2.2 In Using 7
3. Introduction 7
3.1 Features 7
3.2 Specication 9
3.3 Equipment interface instruction 11
4. Safe handling of lithium batteries guide 15
4.1 Schematic diagram of solution 15
4.2 Danger label 15
4.3 Tools 15
4.4 Safety Gear 16
5. Installation and operation 16
5.1 Package items 16
5.2 Installation location 18
5.3 Grounding 18
5.4 Put into cabinet or racks 19
5.5 Put into bracket 21
5.6 Suitable breaker 23
5.7 Power on 24
5.8 Power off 25
5.9 Multi-group mode 25
6. Trouble shooting 27
7. Emergency Situations 30
8. Remarks 31
R4824_Operating_Manual_17.05.2021.indd 3R4824_Operating_Manual_17.05.2021.indd 3 17.5.2021 14:15:5117.5.2021 14:15:51

R4824_Operating_Manual_17.05.2021.indd 4R4824_Operating_Manual_17.05.2021.indd 4 17.5.2021 14:15:5217.5.2021 14:15:52

1. Symbol in label, manual and product
Caution! Warning! Reminding.
Safety related information.
Risk of battery system failure or life cycle reduces.
Do not reverse connection the positive and negative.
Do not place near open ame.
Do not place at the children and pet touchable area.
Warning electric shock.
Warning Fire.
Do not place near ammable material.
Read the product and operation manual before operating the
battery system!
Grounding.
Recycle label.
The certicate label for EMC.
Label for Waste Electrical and Electronic Equipment (WEEE)
Directive (2012/19/EU).
The certicate label for Safety by TÜV Rheinland.
5
R4824_Operating_Manual_17.05.2021.indd 5R4824_Operating_Manual_17.05.2021.indd 5 17.5.2021 14:15:5217.5.2021 14:15:52

2. Safety Precautions
Reminding
1. It is important and necessary to read the user manual carefully (in the accessories)
before installing or using battery. Failure to do so or to follow any of the instructions
or warnings in this document can result in electrical shock, serious injury, or death,
or can damage battery, potentially rendering it inoperable.
2. If the battery is stored for long time, it is required to charge them every six months,
and the SOC should be no less than 90%.
3. Battery needs to be recharged within 12 hours, after fully discharged
4. Do not install the product in outdoor environment, or an environment out of the oper-
ation temperature or humidity range listed in manual.
5. Do not expose cable outside
6. Do not connect power terminal reversely.
7. All the battery terminals must be disconnected for maintenance
8. Please contact the supplier within 24 hours if there is something abnormal.
9. Do not use cleaning solvents to clean battery.
10. Do not expose battery to ammable or harsh chemicals or vapors.
11. Do not paint any part of battery, include any internal or external components.
12. Do not connect battery with PV solar wiring directly.
13. The warranty claims are excluded for direct or indirect damage due to items above.
14. Any foreign object is prohibited to insert into any part of battery.
Warning
2.1 Before Connecting
1. After unpacking, please check product and packing list rst, if product is damaged or
lack of parts, please contact with the local retailer
2. Before installation, be sure to cut off the grid power and make sure the battery is in
the turned-off mode
3. Wiring must be correct, do not mistake the positive and negative cables, and ensure
no short circuit with the external device
4. It is prohibited to connect the battery and AC power directly
5. The embedded BMS in the battery is designed for 48VDC, please DO NOT connect
battery in series
6
R4824_Operating_Manual_17.05.2021.indd 6R4824_Operating_Manual_17.05.2021.indd 6 17.5.2021 14:15:5217.5.2021 14:15:52

6. Battery must connect to ground and the resistance must be less than 0.1Ω
7. Please ensured the electrical parameters of battery system are compatible to related
equipment
8. Keep the battery away from water and re.
2.2 In Using
1. If the battery system needs to be moved or repaired, the power must be cut off and
the battery is completely shutdown
2. It is prohibited to connect the battery with different type of battery.
3. It is prohibited to connect batteries with faulty or incompatible inverter
4. It is prohibited to disassemble the battery (QC tab removed or damaged);
5. In case of re, only dry powder re extinguisher can be used, liquid re extinguishers
are prohibited
6. Please do not open, repair or disassemble the battery except staffs from TAB or
authorized by TAB. We do not undertake any consequences or related responsibility
which because of violation of safety operation or violating of design, production and
equipment safety standards.
3. Introduction
R4824 lithium iron phosphate battery is the new energy storage products developed and
produced under TAB’s quality requirements, it can be used to support reliable power for
various types of equipment and systems.
R4824 has built-in BMS battery management system, which can manage and monitor cells
information including voltage, current and temperature.
3.1 Features
1. NEW: Build-in soft-start function able to reduce current strike when inverter need to
start from battery.
2. NEW: Dual active protection on BMS level.
3. NEW: Automatic address setting when connect in multi-group.
4. NEW: Support wake up by 5~12V signal from RJ45 port.
5. NEW: Support upgrade battery module from upper controller via CAN or RS485
communication.
7
R4824_Operating_Manual_17.05.2021.indd 7R4824_Operating_Manual_17.05.2021.indd 7 17.5.2021 14:15:5317.5.2021 14:15:53

6. NEW: Enable 95% depth of discharge, available for the inverter which completely
follow TAB latest protocol to operate.
7. The module is non-toxic, non-pollution and environmentally friendly.
8. Cathode material is made from LiFePO4 with safety performance and long cycle
life.
9. Battery management system (BMS) has protection functions including over-dis-
charge, over-charge, over-current and high/low temperature.
10. The system can automatically manage charge and discharge state and balance
voltage of each cell.
11. Flexible conguration, multiple battery modules can be in parallel for expanding
capacity and power.
12. Adopted self-cooling mode rapidly reduced system entire noise.
13. The module has less self-discharge, up to 6 months without charging it on shelf, no
memory effect, excellent performance of shallow charge and discharge.
14. Small size and light weight, standard of 19-inch embedded designed module is
comfortable for installation and maintenance.
15. Compatible with R4836.
*Mixture using master battery priority: R4836>R4824
For same type of module always use the latest production unit as master.
*Mixture using battery deployment option:
Master battery (1st) R4836/R4824
Slave 2nd ~8th R4836/R4824
Slave 9th ~16th R4836/R4824
8
R4824_Operating_Manual_17.05.2021.indd 8R4824_Operating_Manual_17.05.2021.indd 8 17.5.2021 14:15:5317.5.2021 14:15:53

3.2 Specication
9
R4824_Operating_Manual_17.05.2021.indd 9R4824_Operating_Manual_17.05.2021.indd 9 17.5.2021 14:15:5417.5.2021 14:15:54

Basic Parameters R4824
Nominal Voltage (V) 48
Nominal Capacity (Wh) 2400
Usable Capacity (Wh) 2280
Dimension (mm) 440*410*89
Weight (Kg) 22.5
Discharge Voltage (V) 44.5 ~ 53.5
Charge Voltage (V) 52.5 ~ 53.5
Recommend Charge/Discharge Current (A) 25
Max. Charge/Discharge Current (A) 50-89@60sec
Peak Charge/Discharge Current (A) 90~200@15sec
Communication RS485, CAN
Depth of discharge (%) 95
Conguration (max. in 1 battery group) 16pcs
Working Temperature 0°C ~50°C Charge
-10°C ~50°C Discharge
Shelf Temperature -20°C ~60°C
Short current/duration time <4000A/2ms
Protective class I
IP rating of enclosure IP20
Humidity 5 ~ 95%(RH) No Condensation
Atitude (m) <4000
Certication TÜV / CE / UN38.3
Design Life 15+ Years (25°C/77°F)
Cycle Life >6,000 25°C
Reference to standards IEC62619, IEC63056 UL1642,
IEC61000-6-2, IEC61000-6-3, UN38.3
10
R4824_Operating_Manual_17.05.2021.indd 10R4824_Operating_Manual_17.05.2021.indd 10 17.5.2021 14:15:5417.5.2021 14:15:54
Tabla de contenidos
Manuales populares de Paquete de baterías de otras marcas

IOGear
IOGear GBP24V Series Manual de usuario

Inventus Power
Inventus Power PROTRXion S-12V100-TRX-HD Manual de usuario

Clas Ohlson
Clas Ohlson PW-290A Manual de usuario

EINHELL
EINHELL MULTI-Ah Power X-Change Plus Manual de usuario

Samsung
Samsung EB-U3300 Manual de usuario

ECTIVE
ECTIVE LC Series Manual de usuario