T-SPA T-800 VERSION 4 Manual de usuario

Page 1
Version: T-800
VERSION: T-800
MODEL: MURANO PEDICURE CHAIR
OWNER MANUAL
PLEASE SAVE THIS MANUAL FOR FUTURE REFERENCE

Page 2
Version: T-800
TABLE OF CONTENTS
Safety & Precaution 03
Specification 08
Identify Your Foot Spa 09
Foot-spa Clearance 10
Installations 11
Operation & Use 17
Maintenance & Use 19
Warranty & Service 21
UL Certificate 23
Warranty Registration Form 14

Page 3
Version: T-800
DANGER: Risk of Electric Shock. Connect only to a circuit protected by a ground fault
circuit interrupted
GROUNDING IS REQUIRED. The unit should be installed by a qualified service
representative and grounded.
Install to permit access for servicing.
CAUTION: Risk of electric shock. Disconnect electric power before servicing.
WARNING: Risk of accidental injury or drowning; children should not use hydro
massage bathtub with- out adult supervision.
WARNING: Risk of accidental injury or drowning; do not use hydro massage bathtub
unless all suction guards are installed to prevent body and hair entrapment.
WARNING: To avoid injury, exercise care when entering or exiting the hydro massage
bathtub.
WARNING: Risk of accidental injury or drowning, do not use drugs or alcohol before or
during the use of a hydro massage bathtub equipped with heater to avoid
unconsciousness and possibledrowning
WARNING: Risk of fetal injury; pregnant or possibly pregnant women should consult a
physician before using a hydro massage bathtub equipped with heater.
WARNING: Risk of hyperthermia and possible drowning; do not use a hydro massage
bathtub equipped with heater immediately following a strenuous exercise
WARNING: Risk of electric shock; do not permit electric appliances (such as a hair dryer,
lamp,telephone, radio, or television) within 1.SM (5 feet) of this hydro massage bathtub.
CAUTION: Test the ground fault circuit interrupted protecting this appliance periodically
in accordance with the manufacturer’s instructions
SAFETY & PRECAUTION

Page 4
Version: T-800
WARNING: Risk of hyperthermia and possible drowning; water temperature
inexcessof38°C(100.4°F) may be injurious to your health. Check and adjust water
temperaturebeforeuse.
WARNING: Risk of hyperthermia; people using medications and/or having an adverse
medical history should consult a physician before using a hydro massage bathtub
equipped with heater.
WARNING: It is very important that you carefully follow the basin cleaning procedures
on page 17 to ensure that the spa is sanitized after each use. T-SPA is not liable for any
infections or disease that may result from improper cleaning or failure to adhere to
sanitation requirements.
This pedicure spa unit should only be operated in a room temperature between 40°F (4°C) and
100°F(38°C). DO NOT
use unit outdoorsorin excessively humidordusty environments.
DO NOT use unit where aerosol (spray) products are being used or oxygen is being
administered. DO NOT operate unit if it has been damaged.
Always connect this unit to a properly grounded electrical outlet. This unit is designed
only to operate on a standard 110 Volt 60Hz current. Exceeding this standard may cause
injury and/or seriousbodily harmand/ordamage to property.
DO NOT use this unit if noise above normal sound is heard.
To reduce the risk of burns, fires, and electrical shock, never leave this unit unattended if
plugged in and always unplug when not in use for an extended period, before
installation, cleaning, or removal of parts. Keep the power cord away from heated
surfaces.
DO NOT operate unit if the power cord or plug has been damaged.
If this unit is operating abnormally or malfunctioning, immediately turn off the
power and disconnect the power cord from the outlet; do not operate unit if it is
not working properly.
SAFETY & PRECAUTION

Page 5
Version: T-800
Intheeventofapowerfailure,alwaysturnthepowerswitchtoitsOFFposition. Whennotin
use alwaysturn the powerswitchOFFposition.
To disconnect unit, turn all controls to OFF position and remove power cord from the
outlet. Keepallelectrical devices awayfrom this unit.
This unit only has a weight capacity of 300pounds (136.06 kg). Enter and exit the unit
slowly and carefully.
Never drop or insert any object into any opening of the unit.
Close supervision is necessary when this unit is used by, on or near children, invalids, and
disabled persons. Do
notstandorallowanyonetostandinthespabasin.
Please be aware that a spa basin filled with water is a potential drowning hazard.
Check the water temperature before each use; water temperature should not exceed
105°F (41°C) and water temperature in heater should not exceed 150°F (65°C).
Disinfect the spa basin and jets, after each use with an approved cleaner.
Do not massage any area of the body that is swollen, inflamed, or covered with skin
eruptions. Before operating the massage chair, make sure the chair arms are down.
If there is severe discomfort during the massage, discontinue use and consult a
physician. Donotusethe massagechairformorethan15minutesatonetime.
Do not put hands or fingers near massage mechanism or rollers while the chair is
operating; touching the mechanism can result in injury from the rollers squeezing
together.
Keepthemassagechairanditsairopeningscleanandfreeof hair and dust;neveroperate
themassage chair if the air openings areblocked.
Misuse or failure to properly clean pedicure spa unit may result in serious health issues,
bodily injury, and/or death.
SAFETY & PRECAUTION

Page 6
Version: T-800
HEALTH RISK WARNING:
Use of the pedicure spa unit should be pleasant and comfortable; if there is any pain or
discomfort, stopuseofthe
pedicure spaimmediately.
A physician should be consulted before use of the massage chair by anyone with the
following conditions: Malignant tumor, heart disease, pregnancy, Conditions requiring
rest, and back disease or trouble from an injury or accident.
A physician should be consulted before use of the spa basin and jets, by anyone with
diabetes,swelling,fracture,or
persistent pain.
Anyone with inflamed legs or feet, open wounds, or fungal infections should not use the
spa basin and jets.
Misuse or failure to properly clean pedicure spa unit may result in serious health issues,
bodily injury, and/or death.
WARNING - GROUNDING INSTRUCTIONS AND METHODS:
This unit must be grounded. If it should malfunction or break down, grounding provides
a path of least resistance for electrical current to reduce the risk of electric shock. All
outlets connected to epicures as must include a GFCI device (Ground Fault Circuit
Interrupter). Thiswillreducetheriskofelectric shock.
This unit is for use on a standard 110 Volt 60Hz current.
This unit is equipped with a cord having an equipment grounding conductor and a
grounding plug. The plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
If you are in doubt as to whether this unit is properly grounded, check with a qualified
electrician or serviceman. Fatal electric shock and fire could occur with improper
connection of the equipment- grounding conductor. Do not modify the plug provided
with the product for any reason; if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAFETY & PRECAUTION

Page 7
Version: T-800
WARNING: THERMAL RESETTING PROTECTION DEVICE
The massage chair is equipped with a thermal resetting protection device. This is a
safety feature to protect it from overheating. If the chair should suddenly stop and will
not start, turn the main power switch off, and do not operate the chair for at least 30
minutes. Failure to turn the chair off may result in the chair starting unexpectedly when
the device cools.
SAFETY & PRECAUTION

Page 8
Version: T-800
VERSION: T-800
Dimension (Shipping)
Pedicure Spa
Massage Chair
Stool
55L x 28W x 20H
44L x 31W x 24H
21L x 27W x 17H
Weight (Shipping)
Pedicure Spa
Massage Chair
Stool
150 lbs.
120 lbs.
17 lbs.
Capacity
T-800
4.5 US Gal
Switch
On/Off Air Activated Switch
Power Source
Dedicated 15A Wall Outlet.
Require Pipe-less whirlpool
motor
120V, 0.4A, 60Hz
Water Pump Power Source
Discharge Pump motor
(optional)
115V, 3.2A, 60Hz
Massage System
120V, 60Hz
Plumbing Source
Hot Water
Cold Water
Drain
3/8 inches
3/8 inches
1-1/4 inches –1-1/2 inches
Warranty
Unit
Optional Item
1 year
120 Days
SPECIFICATION

Page 9
Version: T-800
SEAT OPERATION
SPA DIMENSION
IDENTIFY YOUR FOOT-SPA
Armrest can be raised up/down
Reclining 25’’
Chair Sliding
Length 50”
Front Width 22”
Rear Width 27”
Height 60”

Page 10
Version: T-800
WALL CLEARANCE
TYPICAL FOOT-SPA
FOOT-SPA CLEARANCE
22” between
edge of spa and wall
23” between
manicure trays
50” between each spa
Tabla de contenidos