Adjust operational function (x2 for 24V system)
You
must fit the ignition feed for this function to work. Warning and helpful hint. The first time you try this
the odds are you will get confused, at any stage if
you get confused simply stop. Do not randomly
push the button, wait about 10-15 seconds and the
program will reset to its original setting where upon
you can start again.
restrictions on some operations, and, if you miss simply press the Program/Setup button for up to 60
The unit has 3 different function settings to cover the time slot then one could become confused. seconds until an LED comes on. Then release the
all charging requirements, each function can be button.
2)To adjust in the unit in position, there are 3 times
selected by using the green switch marked SETUP 2)At least one LED should now show the unit is
when you can adjust the functions.
/ADJUSTMENT on the front panel, this allows active. Press and hold down the green button for
A) When the unit is first activated ( it will select 12-
program and voltage value changes, all the about 8 seconds until all 3 green LEDs are flashing,
24V operation ) after the voltage selection
changes will remain until changed again by using then release the button. After you realise the button
operation it will remain active for about 5-8 mins
this function. they will flash at a faster rate, this is to show you
before going into sleep mode, this gives you the
default(factory are now in the function adjust mode.
opportunity to change the function setting if
setting) relay on when engine voltage reaches 3) With the 3 LEDs flashing fast, its a simple case
required.
13.3 volts (automatic, no ignition feed required).Off of pushing and releasing the button, the first time
B) At any stage when the unit is active you can also
when the voltages on both sides drop below 13V you do this the 3 flashing LEDs will go off and only
change the functions.
relay on one LED will flash, to select a different LED simply
c) If the unit is on sleep mode ( i.e. installed but the
with voltage above 13.3V on either side of the push the button again, each time you push and
input voltage is too low to actually engage the unit
unit, i.e. charge both ways, off when both drop release the button you will select a different green
) then the unit can be forced out off sleep mode (
below 13V (no ignition feed required). LED (and so a different function)
i.e. no LEDs are on and the applied voltage is
when the flashing LED is on the function legend
below 13V but greater than 6V) then simply press
relay on when you desire then simply hold the button down for
the green select button for up to 60 seconds until a
ignition feed live and voltage above 13.3, relay off about 5 seconds, the LED will flash for the 5
LED comes on.
when ignition feed off or V below 13V. One way
charge only, no back feed with engine off. seconds you hold the button then the LED will lock
With at least 1 LED on: on (stop flashing and become permanent) and save
you selection. Release the button, there is no need
to touch the button again.
The factory setting (default) should fit
the largest percentage of operations. At any time you wish to alter the basic functions
To adjust the preset factory setting use the green simply go through the above procedures again.
adjust button.
1) Please read through this section before 1)If in sleep mode (no LED on, but connected)
attempting the process as there are time
fig 1
Function 1
Function 2
Function 3
To adjust function settings
function 1
auto activation one way
auto activation either way
ignition activation mode
Adjust factory preset voltages
To get out of program :
To continue to set the relay voltage off setting.
Relay On setting x 2 for 24 volt unit Relay off voltage setting x 2 for 24 volt unit
Warning and helpful hint. The first time you try
this the odds are you will get confused, at any
stage if you get confused simply stop, do not
randomly push the button, wait about 10-15
seconds and the program will reset to its original
setting where upon you can start again.
voltage adjust mode. At this stage you have 2 choices, either continue
3) To actually adjust the preset voltage, please and set the relay off voltage or get out of the
Not recommenced unless absolutely necessary look at the table below. Choose the voltage you program having set the relay on setting only.
as this can get rather complex. require and push the button that number of times. (please note, it’s important for obvious reasons
The voltages which can be adjusted are : I.e. for 13.1 volts for the relay to engage push the that the on setting must be a minimum of 0.2 volts
Relay on: pre-factory set at 13.3 volts button 4 times to select that voltage. Then stop. ( higher than the off setting, if you have overlooked
Relay off : pre-factory set at 13.0 volts see fig 3 ) a green LED will flash according to your this, the software will automatically adjust the
To adjust the preset factory setting use the green settings, i.e. it will flash 4 times then stop, then 4 relay off setting to this minimum requirement )
adjust button. times then stop etc. if you are happy with this Having released the green
1) Please read through this section before setting then press the green button and hold it for a button and the yellow LED is fast flashing, then
attempting the process as there are time minimum of 10 seconds until the yellow program press and hold the green button again for about
restrictions on some operations, and if you miss LED starts to flash. ( see below to carry on from 10 sec until all 3 green LEDs come on, then
the time slot then one could become confused. this position ). If you are not happy with the setting release the green button and the unit will be set to
2) To adjust in the unit in position, there are 2 of ( for example 4 ) and you really wanted 5 then the new voltages.
options, you can either adjust the unit with the unit simply push the button again until you get 5 green At
operational ( i.e. over 13.3V has been applied to flashes, if you are already at 4 and, for example, the above position where the yellow LED is on
the input and at least one LED is on to show the you really wanted 3 then simply keep pushing the fast flash you are now in relay off voltage control,
unit is active ) or if you wish to adjust the unit and button through the whole sequence where it will simply select the voltage you require and push
the unit is on sleep mode ( i.e. no LEDs are on then return to 1 flash again, then keep going to 3 the button the number of times to select the
and the applied voltage is below 13V but greater etc . voltage. Please note you cannot select an off
than 6 volts ) then simply press the If you want to exit this stage for any reason simply voltage which is within 0.3 volts of the on voltage.
Program/Select button for up to 60 seconds until do not push the button for 30 secs and the unit will The internal software will prevent you doing this
a LED comes on. Release the button. reset to the settings it was at before programming. for obvious reasons .
With at least 1 LED on or flashing:
0 flash = factor preset 13.3 v 0 flash factor setting 13 volts
1 flash = 12.8V 1 flash = 12.5V
2 flashes = 12.9V 2 flashes = 12.6V
3 flashes = 13.0V 3 flashes = 12.7V
4 flashes = 13.1V 4 flashes = 12.8V
5 flashes = 13.2V 5 flashes = 12.9V
1) If in sleep mode press the Program/Select 6 flashes = 13.3V 6 flashes = 13.0V
button for up to 60 seconds until an LED comes 7 flashes = 13.4V 7 flashes = 13.1V
on. Release the button. 8 flashes = 13.5V 8 flashes = 13.2V
2) At least one LED should now be on or flashing 9 flashes = 13.6V 9 flashes = 13.3V
to show the unit is active. Press and hold down 10 flashes = 13.7V 10 flashes = 13.4V
the green button for a minimum of 16 seconds 11 flashes = 13.8V 11 flashes = 13.5V
(you will see all 3 green LEDs flashing but keep After holding the green button down for 10 The green LED will flash in accordance with the
pressing the switch!!) until the yellow program seconds ( and the yellow LED starting to flash to voltage selected as per above table.
adjust LED is flashing, then release the button. confirm this setting the green LED will switch off ) On completion simply hold the button down for 10
After you release the button the yellow LED will to confirm your relay on voltage selection, then secs until all 3 green LEDs come on flashing, this
remain on constantly. ( no flashing ) this is to release the button and the yellow LED will flash is the program new setting complete.
show you that you are now in the Relay on faster.