1514 GP8002.AGP8002.A
FILTER MONITOR (FAR LEFT) CONT.
When the batteries in the Filter Monitor are ready to be changed, the system will beep intermittently,
and a battery icon will appear in the upper center of the Monitor display.
RO WATER QUALITY MONITOR (CENTER)
The RO Monitor gives both source and RO water quality
readings. To get the source water quality, ensure the Monitor
is on with the white switch in the left hand position. To get
the RO reading, ensure the Monitor is on with the white
switch in the right hand position. To attain the most accurate
reading, run the water for 30 seconds prior to taking the
reading.
DI WATER QUALITY MONITOR (FAR RIGHT)
The DI Quality Monitor gives water quality readings for both
Stage 4 Cartridges. DI-1 refers to the leading (left-most) Stage
4 Cartridge. To get the water quality reading for DI-1, ensure
the Monitor is on with the white switch to the left. DI-2 refers
to the secondary (right-most) Stage 4 Cartridge. To get the
water quality reading for DI-2, ensure the Monitor is on with
the switch to the right.
STEP BY STEP FILTER REPLACEMENT INSTRUCTIONS
Thanks to internal valving, cartridge change outs are simple and easy. It is not necessary to shut off
the source water from the supply tee. Water flow is automatically shut off when a cartridge is removed.
Please have a towel nearby for excess water in cartridges.
IMPORTANT: After installing the new cartridges and UV light, please read the Monitor Reset
Instructions to properly reset the Filter Monitor.
1. Before removing a cartridge, place a large “X” on the cartridge to be replaced to avoid any confusion
when the new cartridge is introduced.
2. If you are changing the Stage 3 Cartridge, it will be necessary to remove Stage 1 and close the
Reserve Storage Tank before replacing. To fully unscrew the Stage 3, remove the stem elbow from the
bottom of the cartridge. Simply push in on the collet and pull out on the stem elbow to remove. You
will reinstall the stem elbow by pressing the fitting into the collet once the new Stage 3 Cartridge is in
place.
3. To remove a cartridge, rotate counter clockwise until the cartridge is free of the valve head. A small
amount of water may escape during this process. Don’t panic, this is normal.
4. Before placing a new cartridge in the system, write the installation date in the space provided on the
label. Remove the yellow cap from the top of the cartridge, and rotate the cartridge clockwise into the
valve head to secure it. Ensure cartridge is fully screwed in.
5. Reprogram the Filter Monitor. Reference Reset Monitor Instructions located at www.sterisil.com.
6. The final step when changing cartridges is to run water for 60 seconds. For change outs on Stages
1-4, close the Reserve Tank and run the autoclave water. For Stage 5 change outs, close the Dental
Storage Tank, and run the dental water (Stage 5).
7. Open all tanks to finish.
8. Cartridges can either be discarded in the trash or returned to Sterisil®for recycling. For more
information on our recycling program visit sterisil.com/recycle.
2
STERISIL®RECYCLING PROGRAM
Sterisil offers a free recycling program, allowing customers to recycle their used Sterisil®
Cartidges by a click of a button. Simply visit sterisil.com/green or call us directly to
request a free shipping label.
While other companies dispose 100% of their used products to a landfill, Sterisil is able to
recycle 91% of our Straws and Cartridges. In addition to recycling, Sterisil contributes to a
greener environment by being the only dental waterline company to offer a residual
disinfectant that meets BMP compliance by not increasing the mercury output in
amalgam separators.
Do not look at the light when on. The ultraviolet light can cause eye damage.
REPLACING THE UV LIGHT
1. Unplug the bulb from the unit.
2. Use a flat head screw driver to pry out the white/clear piece and remove light.
3. Insert the new bulb until it clicks into place.
IMPORTANT: Do not touch the bulb. Grease from hands can cause damage to the lamp.
LIMITED WARRANTY
Sterisil®warrants the Sterisil®System G4 to be free from defects in parts, materials, manufacturing,
or labor for a period of one year after the device is placed in service by the end user (the “Warranty
Period”), and on select electrical components from the date of Sterisil’s Purchase. This Limited
Warranty does not include user replaceable parts required for routine maintenance of the product,
or damage resulting from abuse or neglect of the product, and covers only use of the product for
its intended purpose, and not for any other use. End users should contact Sterisil or an authorized
distributor for claims arising during the Warranty Period. Sterisil reserves the right to repair or replace,
in its discretion, any product that may exhibit a defect during the Warranty Period. Please note that the
bladder tanks need to be replaced approximately every 2 years.
EXCEPT FOR THE FOREGOING LIMITED WARRANTY, ALL Sterisil®PRODUCTS ARE SOLD “AS IS.”
THE FOREGOING LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Sterisil®shall not be liable to any user of any product, or any other person, for any indirect, special,
incidental, exemplary or consequential damages (including, without limitation, lost profits) resulting
from use or inability to use any Sterisil product, arising from any cause of action whatsoever, including
contract, warranty, strict liability, or negligence, even if Sterisil has been notified of the possibility of
such damages. Under no circumstances shall the liability of Sterisil to the user or any other party
exceed the purchase price of the product. No action under the foregoing limited warranty may be
brought more than one (1) year after the expiration of the Warranty Period. Exclusive subject matter and
personal jurisdiction for all disputes arising under this Limited Warranty shall be in the El Paso County
District Court in Colorado Springs, Colorado.