Stellar Hearth CML-58 Manual de usuario

MODELS: CML-58 & CTL-58
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
— Do not store or use gasoline or other
ammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier,
call the re department.
— Installation and service must be performed
by a qualied installer, service agency or
the gas supplier.
WARNING: If the information in these instructions
are not followed exactly, a re or explosion may
result causing property damage, personal injury
or loss of life.
This appliance may be installed in an aftermarket
permanently located, manufactured (mobile)
home, where not prohibited by local codes. A
manufactured home (USA only) or mobile home OEM
installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24
CFR, Part 3280, or when such a standard is not
applicable, the Standard for Manufactured Home
Installations, ANSI/NCSBCS A225.1, or Standard
for Gas Equipped Recreational Vehicles and Mobile
Housing, CSA Z240.4
DO NOT DISCARD
IMPORTANT: This appliance is only for use with
the type(s) of gas indicated on the rating plate.
An LP conversion kit is available when using Liquid
Propane gas; order separately.
These products have been tested and listed
for use in the USA and Canada by:
Underwriters Laboratories,
Northbrook, IL
File #MH47882
www.stellarhearth.com
Linear Direct Vent Gas Fireplaces
Installation and Operating Instructions
Page 1

INS_CXL58-REV I
Page 2
Listing Label Information & Homeowner Reference
This manual should be read thoroughly before installing or operating the replace.
Installers, please leave manual for the homeowner to use for future reference.
Please have the replace model information available when contacting a dealer or Stellar Hearth for additional
information and service work. The model information regarding your replace can be found on the rating plate located in
the valve control area underneath the burner assembly of the replace.
Once you have located the rating plate, record the following information and keep with your records:
Date Installed:_________________________________
Model Name:__________________________________ Type of Gas:___________________________________
MFG Date:____________________________________
Serial Number:_________________________________ Dealer Purchased From: _________________________
Note: Your particular rating plate may look dierent than the plate shown in this example.

Page 3
INS_CLX58_REV I
TABLE OF CONTENTS
Listing Label Information & Homeowner Reference 2
Table Of Contents 3-4
1Safety Information 5
2Commonwealth of Massachusetts Requirements 6
3Specications 7-10
A. Fireplace Dimensions 7
B. Clearances 8
C. Installation Overview 9
D. Placement Clearance Requirements 9
E. Decorative Fronts and Hearth 10
Clean Trim Front 10
Accent Decorative Front 10
Eminence and Inspiration Decorative Fronts 10
4Prepare The Fireplace 11
Stand-O Assembly and Installation 11
5Framing 12-15
A. Wall Enclosure Rough Opening 12
B. Minimum Finished Opening Dimensions 12-13
C. Horizontal Termination 13
D. Vertical Termination 14
E. Corner Installation 14
F. Nailing Flange Assembly and Installation 15
6Mantel Requirements 16
Non-combustible Zone 16
7Glass Frame Assembly 16-17
A. Remove Glass Frame Assembly 17
B. Install Glass Frame Assembly 17
8Optional Fan Kit Installation 18
9Thermostat Remote Control Installation 18
10 Gas Line Connection 19
A. Gas Conversion 19
B. Gas Line Connection 19
11 Venting 20-26
A. Approved Venting 22
4" x 6-5/8" M&G Dura-Vent DV-GD and Selkirk Direct Vent System
B. Horizontal Terminations 20
Vent System Clearances 20
Run Requirements 20
Elbow Requirements 20
C. Vertical Terminations 21
Vent System Clearances 21
Run Requirements 21
Elbow Requirements 21
D. Wall Pass-Throughs 22
E. Horizontal & Vertical Combo Terminations 23
F. Horizontal Term Cap Location & Clearances 24-25
G. Vertical Term Cap Locations & Clearances 26
12 Finishing The Wall 27-29
A. Non-combustible Zone 27
B. Clean Trim Decorative Front 27
C. Accent Decorative Front 28
Material Up To 1" Thick 28
Material Over 1" Thick 28
D. Eminence and Inspiration Decorative Fronts 29
Material Up To 1" Thick 29
Material Over 1" Thick 29
13 CTL-58 Log Identication & Installation 30-31
A. Log Set Identication 30
B. Log Set Installation 30-31
Step 1 Burning Embers 30
Step 2 Logs 1 & 2 Combined Logs 30
Step 3 Logs 3 & 4 Combined Logs 30
Step 4 Log 5 31
Step 5 Log 6 31
Step 6 - Log 7 31
Step 7 - Log 8 31
Step 8 - Log 9 31
Step 9 - Log 10 31

INS_CXL58-REV I
Page 4
TABLE OF CONTENTS
14 CML-58 Reective Panel & Log Installation 32-36
A. Reective Firebox Panels Installation 32
B. Log Set Placement Identication 33
C. Glass Log Set Identication & Installation 33-36
Set 1 - Logs 1 & 2 33
Set 2 - Logs 3 & 4 34
Set 3 - Logs 5 & 6 34
Set 3 - Logs 7 & 8 35
Set 4 - Logs 9 & 10 35
Set 5 - Logs 11 & 12 36
Media Dam, Embers & Glass Media 36
15 CML-58 Light Bulb Replacement 37
16 Valve & Pilot Assembly Components 38-39
A. Valve Wiring Schematic 38
B. IPI Pilot Assembly 39
C. IPI Gas Valve 39
17 Control Module Components 40
A. Main Control Module 40
B. Extension Module, Battery Back-up & AC 40
18 Remote Control Operating Instructions 41-46
A. Remote Control Icon Identication 41
B. Remote Control Information 41
C. Continuous Pilot - Cold Conditions 42
D. Operation Using Battery Power 42
E. Matching Security Codes 42
F. Initial Set-Up 43
G. Gas Type Conversion 43
H. Celsius/Fahrenheit Conversion 43
I. Important Safety Feature 43
J. Continuous Pilot Feature 43
K. Childproof Feature 43
L. Manual Mode 44
M. Fan Mode 44
N. Lighting Mode 44
O. Flame Mode 45
P. Thermostat Mode 45
Q. Operation Without Handheld Remote 46
R. System Operation Without Handheld 46
19 Lighting & Shutdown 47-48
A. Lighting 47
B. Turning O Gas To Fireplace 48
20 Pressure Testing - Inlet 49
21 Error Codes 50
A. Ignition Safety 50
B. Sensor Safety 50
C. Thermal Safety 50
D. Communication Safety 50
22 Finalizing The Installation 51-52
A. Flame Appearance 51
B. Factory Set Venturi Settings 51
C. Venturi Adjustment Guidelines 51
D. To Adjust Venturi 51
E. Restrictor Usage 52
F. Restrictor Troubleshooting 52
G. Restrictor Installation/Modication 52
23
23 Maintenance 53
A. IPI Board System 53
B. Fan 53
C. Vent System 53
D. Glass Cleaning & Replacement 53
24 Troubleshooting 54-55
A. Main Control Module Will Not Work 54
B. Pilot Will Not Light/Stay Lit 54
C. Pilot Flame Always On/Will Not Extinguish 54
D. Pilot Burner But Ignitor Continues To Spark 54
E. Main Flame Will Not Light 55
F. Flame Height Adjustments Not Working 55
G. Room Temp Display On Remote Not Correct 55
H. Fireplace Will Not Respond In Thermo Mode 55
25 Conversion Kit Instructions 56-58
A. Prepare The Fireplace 56
B. Convert Pilot Assembly 56
C. Replace Burner Orice 56
D. Gas Type Conversion 57
E. Convert Gas Control Valve 57
F. Complete The Conversion 57
G. Testing For Leaks 58
H. Inlet Pressure Test 58
26 Replacement Parts 59
Lifetime Limited Warranty 60

Page 5
INS_CLX58_REV I
1 - SAFETY INFORMATION
This replace has been tested to and complies with ANSI Z21.88a-2014·CSA 2.33a-2014
“VENTED GAS FIREPLACE” by Underwriters Laboratories, Northbrook, IL.
Installation must conform with local building codes or in the absence of local building codes, with the National
Fuel Gas Code, ANSIZ223.1/NFPA 54 - Current Edition, or the Natural or Propane Installation Code, CSAB149.1
• Installation and repair should be done only by a qualied service person. The appliance should be inspected by a
qualied service person before use. Annual inspection by a qualied service person is required to maintain warranty.
More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative
that control compartments, burners and circulation air passageways of the appliance be kept clean.
• If this appliance is installed directly on carpeting, tile or other combustible material other than wood ooring, the
appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.
• Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid
burns or clothing ignition.
• Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young
children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are
at risk individuals in the house. To restrict access to a replace or stove, install an adjustable safety gate to keep
toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
• Clothing or other ammable material should not be place on or near the appliance.
• Adequate accessibility clearances for servicing and proper operation must be maintained.
• This appliance must not share or be connected to a chimney ue serving any other appliance.
• Keep area around the appliance clear of combustible materials, gasoline and other ammable vapor and liquids.
• The ow of combustion and ventilation air must not be obstructed.
• Due to high temperatures the appliance should be located out of trac and away from furniture and draperies.
• The glass front or any part removed for servicing the appliance must be replaced prior to operating the appliance.
Work should be done by a qualied service technician.
• Clean glass only when cool and only with non-abrasive cleansers.
• Do not operate this appliance with the glass/frame assembly removed, cracked or broken. The glass assembly, part
# STL-1641 shall only be replaced as a complete unit, as supplied by Stellar Hearth Products. Replacement of the
glass assembly must only be performed by a licensed or qualied service person. DO NOT SUBSTITUTE MATERIALS.
• Do not strike or slam glass assembly.
• A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be
installed for the protection of children and other at-risk individuals.
• If the barrier becomes damaged, the barrier shall be replaced with only the manufacturer's barrier for this appliance.
• Any barrier removed for servicing the appliance must be replaced prior to operating the appliance.
• Under no circumstances should any solid fuel (wood, coal, paper or cardboard etc.) be used in this appliance.
• Keep burner and control compartment clean.
• Do not use this replace if any part has been under water. Immediately call a qualied service technician to inspect
this appliance and to replace any part of the control system and any gas control which has been under water.

INS_CXL58-REV I
Page 6
2 - COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
NOTE: The following requirements reference various Massachusetts and national codes not contained
in this manual.
For all sidewall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or
in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust
vent termination is less than (7) feet above nished grade in the area of the venting, including but not limited to decks and
porches, the following requirements shall be satised:
INSTALLATION OF CARBON MONOXIDE DETECTORS
At time of installation of side wall horizontally vented gas
fueled equipment, the installing plumber or gas-tter shall
observe that a hard wired carbon monoxide detector with
an alarm and battery back-up is installed on the oor level
where the gas equipment is to be installed. In addition,
the installing plumber or gas-tter shall observe that a
battery operated or hard wired carbon monoxide detector
is installed on each additional level of the dwelling,
building or structure served by the side wall horizontal
vented gas fueled equipment. It shall be the responsibility
of the property owner to secure the services of qualied
licensed professionals for the installation of hard wired
carbon monoxide detectors.
In the event that the side wall horizontally vented gas
fueled equipment is installed in a crawl space or attic,
the hard wired carbon monoxide detector with alarm and
battery back-up may be installed on the next adjacent
oor level.
In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply with
the above requirements; provided, however, that during
said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
APPROVED CARBON MONOXIDE DETECTORS
Each carbon monoxide detector as required in accordance
with the above provisions shall comply with NFPA 720
and be ANSI/UL 2034 listed and IAS certied.
SIGNAGE
A metal or plastic identication plate shall be permanently
mounted to the exterior of the building at a minimum of
eight (8) feet above grade directly in line with the exhaust
vent terminal for the horizontally vented gas fueled heating
appliance or equipment. The sign shall read, in print no
less the one-half inch (1/2) in size, “GAS VENT DIRECTLY
BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
INSPECTION
The state or local gas inspector of the side wall horizon-
tally vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector ob-
serves carbon monoxide detectors and signage installed
in accordance with the provisions of 248 CMR 5.08 (2) (a)
1 through 4.
EXEMPTIONS
The following equipment is exempt from 248 CMR 5.08
(2) (a) 1 through 4:The equipment listed in Chapter 10
entitled “Equipment Not Required To Be Vented” in the
most current edition of NFPA 54 as adopted by the Board;
and Product Approved side wall horizontally vented gas
fueled equipment installed in a room or structure separate
from the dwelling, building or structure used in whole or in
part for residential purposes.
MANUFACTURES REQUIREMENTS
GAS EQUIPMENT VENTING SYSTEM PROVIDED
When the manufacturer of Product Approved side wall
horizontally vented gas equipment provides a venting
system design or venting system components with the
equipment, the instructions provided by the manufacturer
for installation of the equipment and the venting system
shall include:
Detailed instructions for the installation of the venting
system design or the venting system components; and
a complete parts list for the venting system design or
venting system.
MANUFACTURES REQUIREMENTS
GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED
When the manufacturer of Product Approved side wall
horizontally vented gas equipment does not provide the
parts for venting the ue gases, but identies “special
venting systems”, the following requirements shall be
satised by the manufacturer:
The referenced “special venting systems” instructions shall
be included with the appliance or equipment installation
instructions and; the “special venting systems” shall be
Product Approved by the Board, and the instructions
for that system shall include a parts list and detailed
Installation instructions.
A copy of all installation instructions for all Product
Approved side wall horizontally vented gas fueled
equipment, all venting instructions, all parts lists for
venting instructions, and/or all venting design instructions
shall remain with the appliance or equipment at the
completion of the installation.

Page 7
INS_CLX58_REV I
B
E
F
G
A
►
▲
▼
◄
►◄
▲
▲
▼
28-1/8
(714 mm)
7-7/8
(200 mm)
I
►
▲
▼
◄
▲
▼
H
2-1/8
(54 mm)
8
(203 mm)
►
▲
▼
◄
►◄
C
D
►
▲
▼
◄
3 - SPECIFICATIONS
A. FIREPLACE DIMENSIONS
LETTER KEY A B CD E F G H I
DESCRIPTION Height Width Back
Width Depth Opening
Width
Glass
Frame
Height
Stand-o
Height
Front to
Vent Center
(Vertical)
Floor to Vent
Center
(Horizontal)
DIMENSIONS
INCHES 24-1/4 51 57-7/8 17 46-7/8 16-1/2 12 9-1/4 52-1/2
mm 616 129.5cm 147.0cm 432 119.1cm 419 305 235 133.4cm
Figure 3A

INS_CXL58-REV I
Page 8
3 - SPECIFICATIONS
WARNING: Top stand-o bracket must be attached to replace. Do not remove. Stand-o brackets are not load-
bearing. Non-combustible zone: Stand-os provide 12” (305 mm) minimum clearance to header. Use only non-
combustible material in this area for entire width of replace. Do not use wood, sheetrock, etc., in this zone. Other
clearances apply. All clearances must be maintained.
WARNING: NON-COMBUSTIBLE ZONE: STAND-OFFS PROVIDE 12” (305 mm) MINIMUM CLEARANCE TO
HEADER. USE ONLY NON-COMBUSTIBLE MATERIAL IN THIS AREA FOR ENTIRE WIDTH OF FIREPLACE.
DO NOT USE WOOD, SHEETROCK, ETC., IN THIS ZONE.
NOTE: OTHER CLEARANCES APPLY. ALL CLEARANCES MUST BE MAINTAINED.
REFER TO PAGE 14 FOR MORE INFORMATION.
B. CLEARANCES Inches mm
Top of unit face to header (cement board may be used in this area) 12 305
From unit left & right sides at rear of unit 1-3/4 45
From surround sides (ush) at front of unit 1/8 3
To ooring under replace 0 0
Unit top to ceiling 31" 788
Unit side to adjacent sidewall 12 305
Mantel 12” (305 mm) deep from top of replace 13-1/2 343
From unit back 1-3/8 35
1-3/4”
(45mm)
1/8”
(3mm)
1-3/8”
(35mm)
12”
(305mm)
▲
►
▼
◄
►◄
►◄
Figure 3B

Page 9
INS_CLX58_REV I
3 - SPECIFICATIONS
C. INSTALLATION OVERVIEW
1. Frame an opening for replace, allowing for vent installation and type of installation (corner, at wall, type of front to be used and/
or clean face application).
2. If masonry (optional) will be used, prepare foundation for the masonry load. A lintel is required to support the added weight
above the replace.
3. Install hearth if desired.
4. Bend out nailing tabs from replace.
5. Insert replace into framing.
6. Complete gas line installation.
7. Complete electrical hook-up. Install any standard or optional electrical components at this time.
8. Complete venting installation.
9. Secure replace to ooring through holes located in outer box bottom and to framing with nailing anges. Verify all clearances at
this point.
10. Install facing material, mantel or cabinetry, allowing room for optional full size fronts, if applicable.
11. Install logs or glass and ember material.
12. Install decorative front.
13. Verify proper operation of replace and all components.
NOTE: The qualied installer should follow the procedure best suited for the installation.
D. PLACEMENT CLEARANCE REQUIREMENTS
• This replace must be installed on a level surface capable of supporting the replace and venting.
• Fireplace must be placed directly on wood or non-combustible surface (not linoleum or carpet) extending entire depth and width
of replace.
• Due to high surface temperatures, replace should be located out of trac and away from furniture and draperies.
• This replace may be installed in a bedroom.
• Please be aware of the large amount of heat this replace will produce when determining a location.

INS_CXL58-REV I
Page 10
3 - SPECIFICATIONS
E. DECORATIVE FRONTS AND HEARTH - VERIFY PRIOR TO FRAMING
CLEAN TRIM FRONT AND HEARTH
ACCENT DECORATIVE FRONT
IMPORTANT: Keep the outer dimensions of the decorative front and hearth specications in consideration, up front, when
planning the framing and nishing of the replace. See Section 12 Finishing The Wall on pages 27-29.
Clean Trim dimensions are 48" x 22-3/4" (1,291mm x 577.8mm) and is an inside t front.
(Hearth) Bottom of fireplace.
53-1/2”
(1,359mm)
25-1/2”
(648mm)
3/4”
(19mm)
▲
►
▼
◄
▲
EMINENCE AND INSPIRATION DECORATIVE FRONTS - Inspiration Front Shown Below
62-1/2”
(1,588mm)
28-1/2”
(724mm)
2-1/4”
(57mm)
(Hearth) Bottom of fireplace.
▲
►
▼
◄
▲
▼
NOTE: PLEASE REFER TO SECTION 12 FINISHING THE WALL (PAGES 27-29) FOR MORE IMPORTANT INFOR-
MATION ON THE FINISHING MATERIAL CONSIDERATIONS FOR THE DIFFERENT DECORATIVE FRONTS.
Figure 3E.1
Figure 3E.2
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Chimenea de interior de Stellar Hearth

Stellar Hearth
Stellar Hearth GALAXY Series Manual de usuario

Stellar Hearth
Stellar Hearth SM-INS Manual de usuario

Stellar Hearth
Stellar Hearth IGL26 Manual de usuario

Stellar Hearth
Stellar Hearth VP-36M Viewpoint Series Manual de usuario

Stellar Hearth
Stellar Hearth VP-36M Manual de usuario

Stellar Hearth
Stellar Hearth GALAXY Series Manual de usuario

Stellar Hearth
Stellar Hearth CTL-58-AF Manual de usuario

Stellar Hearth
Stellar Hearth viewpoint VP-48TP Manual de usuario

Stellar Hearth
Stellar Hearth GALAXY Series Manual de usuario

Stellar Hearth
Stellar Hearth LG-INS Manual de usuario