Stanley NMARBI100 Manual de usuario

SAFETY INFORMATION
WARNING
If theinformationintheseinstructionsare
not followed exactly,afireorexplosion
mayresult causingpropertydamage,
personalinjuryorlossoflife.
Do not storeoruse gasolineorotherflammablevapors
and liquidsinthevicinity ofthisorany otherappliance.
INSTALLER:LEAVETHIS MANUALWITH THE APPLIANCE.
CONSUMER:RETAINTHISMANUALFOR FUTURE REFERENCE.
Version:202111
NMARBI100
NMARBI130
Argon Built In

2
TABLE OF CONTENTS
Please read and carefully follow all of the instruction found in this manual. The instructions
included here will assure that you have many years of dependable and enjoyable service
from your Stanley product.
IMPORTANT INSTRUCTIONS
.........................................................................................................................................
3
UNPACKING AND TESTING THE APPLIANCE
..........................................................................................................
4
LOCATING THE FIREPLACE
...........................................................................................................................................
4
NMARBI100
.........................................................................................................................................................................
5
NMARBI130
.........................................................................................................................................................................
6
SAFETY DRILL SCREW AREA
.....................................................................................................................................
..7
MANTEL CLEARANCE
...................................................................................................................................................
..7
INSTALLATION
................................................................................................................................................................
..
MEDIA OPTIONS
..............................................................................................................................................................
13
MEDIA INSTALLATION
.................................................................................................................................................
13
OPERATION
.......................................................................................................................................................................
14
MANUAL OPERATION
...................................................................................................................................................
14
REMOTE CONTROL OPERATION
................................................................................................................................
15
WIFI OPERATION
.............................................................................................................................................................
17
CARE AND MAINTENANCE
.........................................................................................................................................
20
REPLACEMENT PARTS
..................................................................................................................................................
21
EXPLODED VIEW
............................................................................................................................................................
22
TROUBLE SHOOTING
.....................................................................................................................................................
23
SERVICE HISTORY
..........................................................................................................................................................
24
WARRANTY
......................................................................................................................................................................
25

IMPORTANT INSTRUCTIONS
PLEASE RETA N TH S USER GU DE FOR FUTURE REFERENCE
When using electrical appliances, basic precautions should always be followed to reduce the
risk of fire, electric shock, and injury to persons, including the following:
1) Read all instructions before using this fireplace
2) The fireplace is hot when in use. To avoid burns, do not let bare skin touch hot surfaces.
Keep combustible material such as furniture, cushions, bedding, paper, clothes, curtains
at least 3 feet/ 915mm from the front of the unit
3) Extreme caution is necessary when any heater is used near children and whenever the
unit is left operating and unattended.
4) Do not operate a fireplace with a damaged cord or plug, or if the heater has
malfunctioned, the fireplace has drooped or damaged in any manner
5) This fireplace is not suitable for use in wet areas such as bathrooms or utility rooms.
6) Do not run the cord under carpeting. Do not cover cord with throw rugs, runners or the
like. Arrange the cord away from traffic area and where it will not be tripped over
7) Do not modify this fireplace. Use it as described in the manual. Any other use not
recommended by the manufacture may cause fire, shock or injury to persons
8) Do not use this heater with programmer, timer, separate remote-control system or any
other device that switches the heater on automatically, since a fire risk exists if the heater
is covered or positioned incorrectly
9) Disconnect all power supply before cleaning, maintenance or relocation of the fireplace
10) Keep the heater clean. Do not allow any objects to enter any ventilation or exhaust
opening as this may cause electric shock, fire or damage to the heater
11) Do not immerse the cord, plug or any part of the appliance in water or any other liquid
12) n order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this
appliance must not be supplied through an external switching device
CAUTION: Procedures and techniques, which, if not carefully followed, will result in damage to
the equipment.
WARNIN : Procedures and techniques, which, if not carefully followed, will expose the user to
the risk of fire, serious injury, illness or death.
Consult with professional electrician and adhere to all code requirements for
installations in bathrooms
SAVE THESE INSTRUCTIONS
3

UNPACKINGANDTESTINGAPPLIANCE
Carefullyremovetheappliancefromthebox. Priortoinstallingtheappliance,testtomakesurethe
applianceoperatesproperlybypluggingthepowersupplycordintoaconvenientlylocated240Volt
groundedoutlet.
LOCATINGTHEFIREPLACE
Planwhere tolocateandframethefireplace.This will savetimeandmoneylaterwhenyouinstall
thefireplace.Beforeinstallationconsiderthefollowing:
1. Where thefireplaceis locatedmust allowforwallandceilingclearances(see INSTALLATION)
2. Consideralocationwhere thefireplacescreenwill notbeexposedtodirectsunlight from
windowsordoors.
3. A15 ampere,240 Volt,50 Hz branchcircuit with properground mustbeavailableatthelocation.
Preferablyadedicatedbranchcircuitshouldbeprovidedtoavoidcircuitbreakerstotripoffuses
toblow.
4

Description Built-inAppliance
Voltage 230V ac 50 Hz
Watts 1900WMax
NOHEATER 25W
MOTOR HEATER 19W
ApplianceWidth 38 5/8”or98.1 cm
ApplianceHeight 23 5/8”or60 cm
ApplianceDepth 6 3/4”or17.2 cm
Gross Weight 88 lbsor40kg
PlugLocation Left side
Cord Length 707/8”or180 cm
RoughWall OpeningSize 40”25“or
101.6 cm 63.5 cm
BTU 6500
NMARBI100
5

ModelNumber BI-50-SLIM
Voltage 230V ac 50Hz
Watts 1900WMax
NOHEATER 25W
MOTOR HEATER 19W
ApplianceWidth 48 5/8”or123.5cm
ApplianceHeight 23 5/8”or60 cm
ApplianceDepth 6 3/4”or17.2 cm
Gross Weight 105.6 lbsor48kg
PlugLocation Left side
Cord Length 707/8”or180 cm
RoughWall OpeningSize 50”25“or
127 cm 63.5 cm
BTU 6500
NMARBI130
6

Thereis asafetydrillscrewareaasshow below.
Pleasemakesurethat thefixscrewsare inthis area.
Safetydrill screwarea
(Darkarea)
MANTEL CLEARANCE
4"
Fireplace Mantel
Wall (Combustible facing allowed)
Floor
Fireplace
SAFETY DRILL SCREW AREA
7
The clearance to the mantel should be 4”/ 105mm minimum when a mantel is applied
(Measurement is taken from the trim).

Theroughwall openingsizeof thefireplace:
1. Takeouttheunit fromthebox.Pleasedo thepre-testbeforeyouinstall the fireplace. Pull
outtheoptionaltrim fromtheunit as shows below.
optional trim
Note:Theoptional trim can bepulledoutdirectlyfromtheunit.Itwill need twopeopletodoit.
INSTALLATION
This series of models are designed to be built-in and allow for finishing material (drywall, stone, tile,
etc) to be built right down to the glass edge. However, that application is not always desirable or
available so the surround could be used as an alternate finish option.
w D H
NMARBI100
40”/ 101.6cm
7”/ 17.78cm
25”/ 63.5cm
NMARBI130
50”/ 127cm 7”/ 17.78cm
25”/ 63.5cm

2. Removetheframingplates fromtheunit
framing plate
3. Re-fixtheframingplates to theunit as thepicture shows
framing plate
9

4. Bend up theframingplates.
5. Puttheunit into theopening.
10
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Chimenea de interior de Stanley