Stanley Solis ECO Hoja de especificaciones

Solis ECO Monoblock
Air to Water Heat Pump
Operation and Installation Manual

Contents
1. Preface ...................................................................................................................................................... 2
2. Safety Instructions ..................................................................................................................................... 3
3. Features .................................................................................................................................................... 5
4. Unit Dimension (mm) ................................................................................................................................. 8
5. Handling & Installation ............................................................................................................................... 8
6. Parameters .............................................................................................................................................. 11
7. Hydronic installation................................................................................................................................. 13
8. Maintenance ............................................................................................................................................ 14
9. Wiring ( including 200 litre cylinder c/w 50 litre buffer internal Unit)......................................................... 16
10. Display Operation Guide ...................................................................................................................... 17
11. Failure List & Troubleshooting .............................................................................................................. 26
1. Preface
In order to provide customers with high-quality, reliable and versatile products, this heat pump is manufactured by
strict design and manufacturing standards.
This manual includes all the necessary information about installation, debugging and maintenance. Please read the
manual carefully before you start or maintain the unit.
The manufacturer of this product will not be held responsible if someone is injured or the unit is damaged, as a
result of improper installation, debugging, unnecessary maintenance which is not in line with this manual.
The unit must be installed by qualified personnel.
It is vital that the below instructions are adhered to at all times to keep the warranty.
—
The unit can only be turned on or repaired by a qualified installer or an authorized dealer.
—
Maintenance and operation must be carried out according to the recommended time and frequency, as stated in
this manual.
—
Use standard spare parts only.
Failure to comply with these recommendations will invalidate the warranty.
Inverter air to water heat pump is a high efficiency, energy-saving and environment-friendly equipment, which is
mainly used for house heating/cooling and hot water. It can work with indoor units such as fan coils, radiators, or
floor heating, for provision of domestic hot water it should be paired with the designated cylinder from Waterford

Stanley which has been tested and approved to the relevant standard to verify compatibility.
2. Safety Instructions
To maintain the safety of the operator and engineers and avoid damage to the unit or to the property it is necessary
to use the heat pump properly, please read this manual carefully and understand the following information correctly.
Symbol Meaning
WARNING
Incorrect operation may lead to death or serious injury to people.
ATTENTION
Incorrect operation may lead to harm of people or loss of material.
Prohibition. What is prohibited will be nearby this icon.
Compulsory implement. The listed action need to be taken.
ATTENTION (include WARNING)
Please pay attention to what is indicated.
Installation Meaning
Professional installer
is required.
The heat pump must be installed by qualified personals, to avoid
improper installation which may lead to water leakage, electrical
shock or fire.
Earthing is required.
Please make sure that the unit and electrical power supply
have good
earthing, otherwise may cause electrical shock.
Operation Meaning
DO NOT put fingers or others into the fans or evaporator of the unit,
Warning
Symbols

PROHIBITION
otherwise harm may occur.
Shut off the
power.
When there is something wrong or strange smell, the power supply
needs to be shut off to stop the unit. To continue running may cause
short circuit or fire.
Move and Repair
Meaning
Entrust
When the heat pump needs to be moved or installed again, please
entrust dealer or qualified person to carry it out. Improper installation
will lead to water leakage, electrical shock, injury or fire.
Entrust
It is prohibited to for the user to repair the unit by the user by
themselves otherwise electrical shock or fire may occur.
Prohibit
When the heat pump needs to be repaired, please entrust dealer or
qualified person to carry it out. Improper movement or repair on the
unit will lead to water leakage, electrical shock, injury or fire.
Installation Meaning
Installation Place
The unit CANNOT be installed near the flammable gas. Once
there is any leakage of the gas, fire may occur.
Fix the unit.
Make sure that the basement of the heat pump is strong
enough, to support the heat pump and will not collapse or
deteriorate.
Need circuit
breaker.
Make sure that there is circuit breaker for the unit, lack of circuit
breaker may lead to electrical shock or fire.
ATTENTION
The appliance shall be stored in a room without continuously
operating ignition sources (for example: open flames, an
operating gas appliance or an operating electric heater.)

Operation
Meaning
Check the
installation.
Please check the installation regularly (one month), to
avoid any decline or damage to the unit which may hurt
people or damage the unit.
Switch off the
power.
Please switch off the power when cleaning or maintenance.
Prohibition
It is prohibited to use copper or iron as fuse. The correct
fuse must be fixed by electrician for the heat pump.
Prohibition
It is prohibited to spray the flammable gas to the heat
pump, as it may cause fire.
3. Features
With new technology of DC Inverter EVI, Solis Eco Monoblock
Series can be used in extremely cold area for heating/cooling, hot water. The Series is featured as follows.
3.1. DC Inverter EVI Heat Pump Technology
a.
Ruking Driver Board
Ruking driver board controls the compressor running precisely basing on water temperature and air temperature.
And it can work with wide voltage of 456V at maximum.
b.
Panasonic Inverter Compressor
Panasonic inverter EVI compressor is adopted for the units to ensure high stability.
c.
DC Fan Motor
DC fan motor with adjustable speed ensures the units’ silent running. This makes the units work more efficiently at
different conditions.
3.2. A+++ Energy Level
Solis Eco Monoblock DC inverter technology enables the heat pump to adjust its frequency from 30Hz - 90Hz
according to real heating requirement. With this technology, Solis Eco Monoblock Series achieve an energy level of
A+++ according to ErP directive.

3.3. Certification GuaranT-junctiond
To meet the European market requirement, the series has achieved several certifications such as CE, ErP, MCS.
3.4. R32 Low GWP Gas
Compared with R410A refrigerant heat pumps, Solis Eco Monoblock Series with R32 gas have a GWP of only one-
third. It is an environment-friendly choice for reducing CO2 emission. Meanwhile, R32 heat pump needs 30% less
amount than R410A heat pump.
3.5. Low Noise of 37dB(A)
With a new internal noise reducing design, Solis Eco Monoblock can realize the lowest noise running of 37dB(A)
when testing at 1 meter, so as to provide a silent living environment for users.
3.6. 5-inch Touch Display
5-inch display has many powerful functions, such as water temperature curve, easy timing, one-key mute, and mute
timer.

3.7. APP & IOT
Simplify your life with WarmLink. Via connection by Wi-Fi or 4G, you can take full control of your heat pump from
anywhere in your home or office with a single app on your smartphone.
This effectively saves manpower during the after-sales service period. The fault report button allows a direct error
reporting channel to the local service provider. When an error has been reported, the service provider can see the
error information of the target heat pump from the background system, and contact users immediately to offer help.

4. Unit Dimension (mm)
4.1. Models: Solis Eco Monoblock
5. Handling & Installation
5.1. Packing List
Heat Pump Unit × 1
Display Mounting Plate × 1
Rubber Feet × 4
Drain Connection × 1

Display Connecting Wire × 1
Thermistor × 1
*optional accessory
5.2. Installation Site Requirement (Unit: mm)

Solis Eco
L 1006
H 805
W 442
A 750
B 473
P1 200
P2 150
P3 B+100
Φ2
Tabla de contenidos
Manuales populares de Bomba de calor de otras marcas

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Manual de usuario

Dimplex
Dimplex LI 16I-TUR Guía del usuario

Carrier
Carrier WSHP Open v3 Guía de configuración rápida

TGM
TGM CTV14CN018A Manual de usuario

Carrier
Carrier 38MGQ Series Manual de usuario

Kokido
Kokido K2O K880BX/EU Guía de solución de problemas

Viessmann
Viessmann VITOCAL 300-G PRO Type BW 2150 Guía rápida

Carrier
Carrier 48EZN Manual de usuario

Viessmann
Viessmann KWT Vitocal 350-G Pro Series Instrucciones de funcionamiento

Ariston
Ariston NIMBUS Manual de usuario

Weishaupt
Weishaupt WWP L 7 Guía del usuario

GE
GE Zoneline AZ85H09EAC Manual de usuario