Spa Electrics WN950 Instrucciones de funcionamiento

INSTALLATION &
OWNER’S MANUAL
6” LED NICHE LIGHT

1
CONTENTS
5
11
11
INSTALLATION INSTRUCTIONS (STEPS 1 - 11)
READ THIS FIRST 2
3
3
4
TOOLS REQUIRED
PRODUCT SUPPORT AND INFORMATION
INCLUDED PARTS
AVAILABLE COLOUR MODES
WIRING DIAGRAM
KEY DIMENSIONS
ELECTRICAL GROUNDING & FCC STATEMENT
14
15
16
17
MULTI-PLUS SETUP
MULTI PLUS - MANUAL OPERATION
FRESH WATER USE ONLY
HORIZONTAL MOUNT ONLY
NOT INTENDED FOR OPERATION OUT OF WATER
NOTICE
FOR SUPPLY CONNECTION, USE ONLY AN ISOLATING LOW VOLTAGE POWER
SUPPLY WITH UNGROUNDED OUTPUT, EVALUATED FOR SWIMMING POOL USE

2
READ THIS FIRST
BEFORE YOU START:
• ParaGlo cables can be shortened to suit individual installation requirements. Spa Electrics
recommends all cabling is protected by conduit and that a junction box (or similar) is
incorporated into pool cabling design to avoid siphoning.
• Ensure that the lighting system is installed by a qualified person (e.g. Registered pool builder
and/or licenced electrician), in accordance with the most current edition and/or amendment of
the NEC wiring code.
• For safe and proper installation, ensure that only those parts supplied with the system are used.
• Maximum installation depth for the ParaGlo 6” Light (WN950) is 1M (40”) below nominal water
level (to top of light)
• The ParaGlo 6“ Light (WN950) Must be correctly installed in or on the wall of the pool with the top
of the lens no less than 4” below the nominal water level.
• All lights should be mounted in a location that is easily accessible without the need for entering
or lowering the pool water.
• At least 2.5ft of cable must remain stored within the Niche to ensure the light can be accessed
above the waterline. (Maximum cable within niche :18AWG /16AWG = 8ft).
CLEANING
• Only use warm water and a soft brush or cloth to clean ParaGlo series lights. DO NOT use
detergents or spirits as this can damage the light and void your warranty.
USE
• Do not operate light unless completely submerged in water.
• Operating the light for at least 15 minutes every week is advised (all year round).
• ParaGlo lights are suited for both domestic and commercial installations and can be operated
continuously (24/7) if required.
•Temperature range for installation, operation and servicing: +32oF ~ +104oF (0oC ~ +40oC)
The ParaGlo 6” Light must only be used with a UL listed 12V AC Class 2 power supply or a
power source intended for swimming pool use (not included).
Minimum power source wattage requirement - 15 Watts per light.
• DO NOT use electronic or switch-mode power supplies with WN950-series lights. These power
supplies will damage the light and void your product warranty.
• Pool chemicals & PH levels: Due to the corrosive nature of unbalanced pool chemicals, Spa
Electrics strongly recommend that your pool water is balanced prior to installing your pool lights or
any plastic or stainless steel components, and tested weekly to maintain these levels. pH levels
should be maintained between 7.2 – 7.6 at all times to ensure the longevity of these components.
> Failure to do so can result in chemical damage to the light housing and pool fittings,
including stainless steel components.
> Please note: Lights or components found to have excessive chemical damage will not
be covered under our manufacturer’s warranty policy
• This light contains no user-serviceable parts; opening the light will void the product warranty.
WARNING
Congratulations on your purchase of a ParaGlo underwater lighting system.
All ParaGlo lights are manufactured by Spa Electrics in Australia from only the highest quality
materials and exclusively distributed through Paramount Pool & Spa Systems, USA.

3
TOOLS REQUIRED
PRODUCT SUPPORT & INFORMATION
•The use of power tools during installation is not recommended as
these devices can cause damage to the light and components.
•All installation steps should be carried out with manual tools only.
•The enclosed images are for illustrative purposes only. Appearances
of parts and assemblies may vary from the enclosed illustrations.
•Please contact your reseller if you have any questions regarding the
correct installation of this product.
• No. 2 Phillips screwdriver
IMPORTANT NOTE
Lights MUST be removed from pool wall and cable disconnected via
plug connection & stored in a safe place.
Red plug cover must be fitted to plug top prior to reinstalling into niche for
winter.
Unless niche/conduit connection is adequately sealed; pool water level
must be drained down 12” below the lowest light(s) position in pool wall.
If possible, all conduits should be checked for accumulated water and
drained if required.
Consult your local pool professional for complete pool winterization
process.
WINTERIZATION
•
•
•
•
•
Phone: TOLL FREE 1800 621 5886
Email: paramount@1paramount.com
Web: www.1paramount.com

4
(TOP CABLE EXIT - NO GLAND)
INCLUDED PARTS
UL LISTING #
NICHE # WN9081 US
LIGHT (Blue) # WN9 CBL US
LIGHT (White) # WN9 CW4 US
LIGHT (Multi) # WN9 CMC US
LIGHT (P / Z*) # WN9 CMC P US
PLUG & CABLE (80ft) # WNP 18AWG 80 US
PLUG & CABLE (100ft) # WNP 18 AWG 100 US
PLUG & CABLE (150ft) # WNP 16AWG 150 US
REQUIRED PART (NOT INCLUDED)
UL LISTED 12V AC CLASS 2 POWER SUPPLY OR POWER SOURCE INTENDED FOR SWIMMING POOL USE.
Minimum power source wattage requirement - 15 Watts per light
Spa Electrics recommends “INTERMATIC PX” safety transformers for use with Quantum & Atom Lights
+ 1 SPARE *
* 1 SPARE TERMINAL COVER PROVIDED FOR
WINTERIZATION (SEE PAGE 3)
1x
NICHE
1x
LIGHT
1x
FOAM
INSERT
1x
FOAM
INSERT
2x
MOUNTING
SCREWS
1x
MOUNTING RING
1x
PLUG +
CABLE
1x
WARRANTY
1x
INSTALLATION
MANUAL

5
1” or
Reinforcement Bars
INSTALLATION
1
ATTACH NICHE TO REINFORCEMENT BARS
2
INSERT AND GLUE 3/4” CONDUIT INTO NICHE
(Before spraying concrete)
Attach the niche to either horizontal or vertical steel mounting bars using wire ties or
similar. Ensure conduit entry is at the top of the niche. (Fig. 1)
Glue length of 1” (bellmouth) or 3/4” conduit into top of niche using PVC solvent cement
(suitable for ABS plastics). Conduit should extend above the water level of the pool.
CAUTION: Ensure that sufficient area behind the niche is dug out to allow for 2-3” of
concrete coverage around the entire niche.
1” (BELLMOUTH) OR ¾” CONDUIT
INSTALLED HERE
WIRE TIES
NICHE
REINFORCEMENT BARS
CAUTION:
The ParaGlo 6” light must be correctly installed in the wall of the pool with the top
of the lens no less than 4” below the nominal waterline of the pool.

6
Depending on your installation requirements, conduits may run to a common
junction box or return directly to the power supply. In either case, it is imperative that
the conduit extends above the water level of the pool at some point in order to
prevent syphoning.
NOTE: Conduit should contain a draw wire to allow for easy installation of power
cable.
RE-BAR
40” (MAX)
2.0“ (MAX)
1.25“ (MIN)
CONCRETE
THICKNESS
POOL FINISH
1” (MAX)
½” (MIN)
2”
MINIMUM
CONCRETE
COVERAGE
SEALING
COMPOUND
WATER
LINE
COPING
5.5” (STANDARD)
4.75” (MINIMUM)
NICHE DEPTH
2ft (MIN) CONDUIT
ELEVATION ABOVE
WATER / GROUND
POWER SUPPLY
(TRANSFORMER)
4” (MIN)
48” (1.22m) MINIMUM
JUNCTION BOX
INSTALL SECONDARY CONDUIT
The ParaGlo 6” (WN950) luminaire
with its plastic housing design and
plastic niche does not require
grounding / bonding when operated
within a Class 2 circuit supply.
SEE PAGE 15 FOR MORE INFORMATION
ELECTRICAL GROUNDING

7
REINFORCEMENT BARS
4
CONCRETE SPRAYING
5
FOAM REMOVAL
Spray concrete, paying particular attention to covering the entire niche. Using fingers,
scoop out the concrete around the front edge of the niche. (Fig 3)
WARNING: Ensure that the concrete is well compacted around the rear and base of the
niche, otherwise the pool may leak.
CAUTION: The front of the niche should not be recessed into the concrete.
(After concrete is sprayed and dry)
Remove foam from niche and if necessary, trim niche back to wall surface. Apply a
waterproof sealant in the recess between the niche and the concrete wall. (Fig 3)
CAUTION: Do not trim more than ¾” from the front of the niche or there may not be
sufficient depth remaining for inserting the light.
* SEALING NOTES
SEALING COMPOUND OR HYDRAULIC
CEMENT REQUIRED TO PREVENT
WATER EGRESS THROUGH POOL WALL.
ENSURE NICHE RIM IS CLEAN, DRY
AND FREE OF DEBRIS PRIOR TO
APPLICATION OF SEALING COMPOUND.
ENSURE SEALING COMPOUND IS
SUITABLE FOR USE WITH ABS
PLASTIC
CONDUIT
CONCRETE
2”
TRIM NICHE BACK TO
WALL SURFACE.
SCOOP OUT CONCRETE AROUND
FRONT EDGE OF NICHE AND
APPLY WATERPROOF SEALANT
IN RECESS

8
6
MOUNTING RING PREPARATION
7
ASSEMBLE MOUNTING RING INTO NICHE
Apply PVC solvent cement to bubble at rear of the mounting ring, and also to the inside of
the niche where the mounting ring is likely to finish. (Approximately 1 ½” inside niche) (Fig.
4)
WARNING: Ensure PVC solvent cement is suitable for ABS plastics.
Slide mounting ring into niche, with ‘TOP’ arrow up; insert until flush against pool wall.
CAUTION: Ensure that the mounting ring is parallel with pool wall as the interior pool
surface must be level with this ring.
TOP MARKER APPLY PVC SOLVENT CEMENT APPLY SEALANT
BUBBLEMOUNTING RING

9
8
APPLY POOL FINISH
9
INSERT CABLING
Using the draw wire, feed the cable from the pool interior, through the niche and conduit
to transformer. Ensure that approximately 2.5ft (min) of cable extends from the niche to
the light, in order to allow the light to be lifted from the water to the pool surround for
servicing.
CAUTION: Do not install the light until after the pool has been acid washed. (Fig. 5)
Plaster or tile interior pool surface, level with raised edge of mounting ring.
CAUTION: Interior surface should not finish more than ½” higher than raised edge of
mounting ring, or the light may not be able to be mounted.
MOUNTING RING RAISED EDGE
CABLE
PLUG TOP WITH TERMINAL COVER
Otros manuales para WN950
1
Tabla de contenidos
Otros manuales de Equipo de iluminación de Spa Electrics
Manuales populares de Equipo de iluminación de otras marcas

Qazqa
Qazqa Suplux SL 3 Black 103062 Manual de usuario

Commercial Electric
Commercial Electric 54568141 Manual de usuario

CREE LIGHTING
CREE LIGHTING 304 Series Manual de usuario

Goobay
Goobay 49867 Manual de usuario

ECOMAN ITALIA
ECOMAN ITALIA LED T8 Manual de usuario

Alkalite
Alkalite Krypton KT-81 Manual de usuario