
5
MinTep and MaxTep: Values can be set in the range from -10 to 50°C.
For example, #24#0#1#15#25# means that you are setting control parameters based on ambient temperature for socket 0 - DY10GSM, 1 -
heating mode: if the temperature drops below 15 °C – socket will switch on, when temperature exceeds 25 °C, the socket will switch off. After
successfully setting the temperature range, this setting will be saved until the socket is reset to default settings.
10 Temperature alarm:
The temperature sensor must be connected to the socket for this function. The temperature range can be set for every single socket
individually. If the ambient temperature is outside the specified limit, the DY10GSM will send an SMS to the master user's phone number.
The master user will send SMS command for:
Alarm activation for DY10GSM socket when the temperature is exceeded: #21#0#1#
Alarm activation for DY10S socket when the temperature is exceeded: #68#name#1#
Setting the DY10GSM temperature alarm range: #22#0#MinTemp#MaxTemp#
Setting the DY10S temperature alarm range: #69#name#MinTemp#MaxTemp#
MinTemp and MaxTemp: Values can be set in the range from -10 to 50°C.
Deactivating the temperature alarm for DY10GSM: #21#0#0#
Deactivating the temperature alarm for DY10GSM: #68#name#0#
11 SMS notification at a change of power outlet status:
By default, the DY10GSM sends SMS notification to the master phone number and other numbers in case of a change of the power outlet
status. The master user can turn this function on or off.
The master user will send SMS command for:
Activation of SMS notification in case of a change of the power outlet status (active in default setting): #03#1#
Deactivation of SMS notification in case of a change of the power outlet status. #03#0#
12 SMS notification in case of a change of power status:
By default, the DY10GSM sends SMS notification when power is lost and restored. This applies only to the DY10GSM socket; the DY10S socket
is not capable of this function. The master user can turn this SMS notification on or off.
The master user will send SMS command for:
SMS notification in case of a change of the power status (active in default setting): #05#1#
Deactivation of SMS notification in case of a change of the power status. #05#0#
SMS notification to user
The DY10GSM will send an SMS notification when the power is lost/restored, temperature alarm triggered or in case of another notification.
By default, it sends messages to the master user and other users. The master user can change the settings of sending notifications to other
users' numbers.
The master user sends SMS command for:
Activating SMS notifications for other users: #16#1#
Deactivating SMS notifications for other users: #16#0#
13 Checking the socket status:
The master user or another user will send SMS command for:
Checking the DY10GSM status: #07#
Checking the DY10S status: #70#
Upon receipt of the SMS command, an SMS message with socket status information will be sent to the user:
GSM-Socket: ON Temp: 23C
“Slave1”: OFF Temp: 30C T
“Slave2”: ON Temp: 23C C
“Slave2”: ON Temp: 25C D
Delayed control socket is marked with “D” symbol. Socket with temperature control feature is marked with "T” symbol. Socket with calendar
control feature activated is marked with “C” symbol.
Checking DY10GSM delayed control parameters: #34#
Checking DY10S delayed control parameters: #63#name#
Checking DY10GSM calendar control parameters: #33#
6
Checking DY10S calendar control parameters: #64#name
Checking DY10GSM temperature control parameters: #32#
Checking DY10S temperature control parameters: #66#name
Checking DY10GSM parameters for temperature alarm: #35#0#
Checking DY10S parameters for temperature alarm: #68#name#
14 SMS notification on weak GSM signal:
The DY10GSM socket can send an SMS message when the GSM signal is weak. The master user can turn this function on/off.
The master user will send SMS command for:
Checking GSM signal level: #27#
Activation of SMS notification when the signal is weak: #27#1#
Deactivation of SMS notification when the signal is weak: #27#0#
SMS response
Weak GSM signal strength alert function ON/OFF
Weak GSM signal alert will send an SMS notification:
Weak GSM signal alert, the CSQ is **
15 Socket re-set:
This function will re-set all socket settings (time, temperature, ranges, etc.) and clear all user numbers.
If the socket does not work as it should, you can reset it to default settings to ensure possible new setting and correct function. DY10S must be
reset before pairing with the main unit (unless it being paired for the first time).
DY10GSM reset to default settings:
Method 1: Press "M" button on the socket for 10s.
Method 2: The master user will send SMS command for:
DY10GSM socket re-set: #08#Password#
Default password setting - 1234
DY10S reset to default settings:
Approach: Press "M" button on the socket for 10s.
16 Password change:
The master user will send SMS command for:
Password change: #04#OldPassword#NewPassword#
Main technical parameters:
Supply voltage 110~230V/50HZ,
Output parameters 110 - 230V/50HZ, 230V/30A(30s)
Max. current 16A
Operating temperature -10
+50
Storage temperature -20
+60
Relative humidity 10-90%
GSM PHASE 2/2+
(including data operation)
Data interface GSM SIM 1.8V/3.0V socket
Frequency and coding 433MHz FSK
Additional socket distance Up to 30m
Measurement sensor range: -10
~50
GSM bands 850/900/1800/1900MHz
SMS commands:
Category Function Command
Defining a user
New user registration #00#
Change of master user’s phone
number: #14#NewMasterNumber#
Adding a new user’s number #06#Family#
Checking other users’ numbers #06#
Deleting another user’s number #15#Family#
Deleting all other user numbers #15#
Pairing the
Pairing the additional socket #60#name#
7
Category Function Command
Disconnecting the additional socket #70#name#
Power outlet
changes
Switching DY10GSM socket on #01#0#
Switching DY10S socket on #61#name#
Switching DY10GSM socket off #02#0#
Switching DY10S socket off #62#name#
Delayed control
Delayed activation of DX10GSM after
pre-set time in minutes #12#0#Minutes#1#
Delayed activation of DY10S after pre-
set time in minutes #63#name#Minutes#1#
Delayed activation of DY10GSM after
pre-set time in minutes #12#0#Minutes#0#
Delayed control
Delayed activation of DY10S after pre-
set time in minutes #63#name#Minutes#0#
Deactivate delayed DY10GSM control #11#0#
Deactivate delayed DY10S control #63#name#0#
Operation by
calendar
Activation of DY10GSM operation by
calendar #19#0#1#
Activation of DY10S operation by
calendar #64#name#1#
Setting calendar parameters for
DY10GSM #20#0#WorkDay#StartTime#EndTime#
Setting calendar parameters for DY10S #65#name#WorkDay#StartTime#EndTime#
Deactivating calendar control for
DY10GSM #19#0#0#
Deactivating calendar control for
DY10S #64#name#0#
Control by
ambient
temperature
Activation of control by ambient
temperature for DY10GSM #23#0#1#
Activation of control by ambient
temperature for DY10S #66#name#1#
Setting temperature parameters for
DY10GSM #24#0#mode#MinTemp#MaxTemp#
Setting temperature parameters for
DY10S #67#name#mode#MinTemp#MaxTemp#
Deactivation of control by ambient
temperature for DY10GSM #23#0#0#
Deactivation of control by ambient
temperature for DY10S #66#name#0#
Temperature
monitoring
Activation of temperature monitoring
for DY10GSM #21#0#1#
Activation of temperature monitoring
for DY10S #68#name#1#
Setting temperature range for
DY10GSM #22#0#MinTemp#MaxTemp#
Setting temperature range for DY10S #69#name#MinTemp#MaxTemp#
Deactivation of temperature
monitoring for DY10GSM #21#0#0#
Deactivation of temperature
monitoring for DY10S #68#name#0#
SMS notification on change of the
power outlet status #03#1#
Deactivation of SMS notification on
change of the power outlet status #03#0#
SMS notification in case of a change of
power status #05#1#
Deactivation of SMS notification in case
of a change of power status #05#0#
SMS
notification
SMS notification to other users #16#1#
Deactivation of SMS notification to
other users #16#0#
Status check Checking the DY10GSM status #07#
Checking the DY10S status #70#
8
Category Function Command
Checking the pre-set values of delayed
control for DY10GSM #34#
Checking the pre-set values of delayed
control for DY10S #63#name#
Checking the pre-set values of calendar
control for DY10GSM #33#
Checking the pre-set values of calendar
control for DY10S #64#name#
Checking the pre-set values of ambient
temperature control for DY10GSM #32#
Checking the pre-set values of ambient
temperature control for DY10S #66#name#
Checking the pre-set values for
temperature alarm DY10GSM #35#0#
Checking the pre-set values for
temperature alarm DY10S #68#name#
Checking GSM signal quality #27#
Turn on weak signal alert #27#1#
Turn off weak signal alert #27#0#
Password
change Password change #04#OldPassword#NewPassword#
Socket re-set Re-set DY10GSM to default settings #08#Password#
The product is CE (Declaration of Conformity) certified
, in accordance with current regulations. On request, at the producer:
[email protected], or
for download at shop.solight.cz. Producer: Solight Holding, s.r.o., Na Brně 1972, Hradec Králové 500 06, Czech Republic