Solas ST-26N Manual de usuario

solasfi res.com 1
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
— Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the fi re
department.
— Installation and service must be performed by
a licensed installer, service agency or the gas
supplier.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE
LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE
AND DRAPERIES.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE
HAZARD OF HIGH SURFACE TEMPERATURE AND SHOULD
STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED
WHEN THEY ARE IN THE SAME ROOM WITH THE APPLIANCE.
DO NOT PLACE CLOTHING OR OTHER FLAMMABLE
MATERIAL ON OR NEAR THE APPLIANCE.
WARNING Improper installation, adjustment, services or
maintenance can cause injury or property damage. Refer to
this manual. For assistance or additional information, consult
a licensed installer, service agency or the gas supplier.
TWENTY6
WALLMOUNT DIRECTVENT
GAS FIREPLACE
INSTALLER: Leave this manual with appliance | CONSUMER: Retain this manual for future reference
INSTALLATION & OPERATION MANUAL
MODELS: ST-26N, ST-26P
Ce manual est disponsible en Francais sur demande.
This appliance may be installed in an aftermarket, permanently
located, manufactured home (USA only) or mobile home, where
not prohibited by local codes.
This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
Report #F19-217
HOT GLASS
WILL CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
DANGER
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and must be installed for the protection
of children and other at-risk individuals.

SÓLAS CONTEMPORARY FIRE
2
INSTALLATION RECORD
The installer should complete the form below that describes the details of the installation. Having
this written record of installation information available will greatly expedite trouble-shooting
should any problem arise with your stove. The installer should keep a duplicate of this form for
their records.
Date Purchased: _____________________________________________________
Dealer: _____________________________________________________________
Date Installed: _______________________________________________________
Installer: ____________________________________________________________
Fireplace Model: TWENTY6
Serial Number: _______________________________________________________
Brand of Venting Used: ________________________________________________
Model # of Vent Cap Used: _____________________________________________
Fuel: (circle one) Natural Gas (NG) Propane (LP)
Was this field converted? (circle one) YES NO
Inlet Pressure (after installation): __________________________________________
Manifold Pressure (after Installation): High Fire: _____________________ in. WC
Low Fire: ______________________ in. WC
Altitude: (feet above sea level) ___________________________________________
Was the Fireplace derated? (circle one) YES NO
If the Fireplace was derated, to what orifice size? _____________________________
Other installation notes: ________________________________________________
___________________________________________________________________
___________________________________________________________________
___________________________________________________________________

solasfires.com 3
CONTENTS
Installation Record .............................................................2
Important Safety Information...........................................5
Specifications......................................................................8
Clearances ...........................................................................9
Massachusetts Requirements.......................................10
Venting.................................................................................11
Assembly & Installation................................................... 19
Gas Connection............................................................... 32
Lighting & Operation ...................................................... 39
Remote Operation............................................................ 41
Gas Conversion ............................................................... 49
Maintenance..................................................................... 54
Maintenance Log.............................................................56
Replacement Parts List .................................................. 57
Control Schematic...........................................................58
Warranty Information......................................................59
WE STRONGLY SUGGEST THAT YOU READ THIS
MANUAL THOROUGHLY BEFORE BEGINNING
THE INSTALLATION OF THIS DIRECT-VENT
GAS FIREPLACE. ALTHOUGH THE BASIC
REQUIREMENTS FOR THE INSTALLATION OF ALL
DIRECT VENT GAS FIREPLACES ARE SIMILAR,
EACH SPECIFIC PRODUCT HAS ITS OWN UNIQUE
SET-UP AND INSTALLATION REQUIREMENTS
THAT MUST BE FOLLOWED EXACTLY. PLAN YOUR
INSTALLATION IN ADVANCE BY CAREFULLY
REVIEWING ALL THE INFORMATION CONTAINED
IN THIS MANUAL.
The information contained in this manual is believed to be
correct at the time of printing. SÓLAS LLC. reserves the right
to change or modify any information or specifications without
notice. SÓLAS LLC grants no warranty, implied or stated,
for the installation or maintenance of your appliance, and
assumes no responsibility for any consequential damage(s).
© 2023 Copyright SÓLAS LLC.
Congratulations on your purchase
of a SÓLAS Fireplace!
We welcome you to the SÓLAS family of gas fireplaces.
Each of our products are skillfully designed and expertly
manufactured in the USA. We take great pride in every
fireplace we make and each product is fully tested
throughout the production process to ensure your
safety and warmth throughout the years.
Sincerely,
The SÓLAS Team
PM
AM
SÓLAS One-Touch
Programmable Thermostatic Remote
(see page 41)

SÓLAS CONTEMPORARY FIRE
4
INSTALLATEUR: LAISSEZ CE MANUEL AVEC L’APPAREIL.
CONSOMMATEUR: CONSERVEZ CE MANUEL AUX FINS DE CONSULTATION ULTÉRIEURE.
AVERTISSEMENT: Assurez vous de bien suivre
les instructions données dans cette notice
pour réduir e au minimum le risque d’incendie
ou d’explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquids inflammables dans
le voisinage de cet ap pareil ou de tout autre
appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le
bâtiment où vous trouvez.
• Appelez immédiatem ent votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service des incendies.
— L’installation et l’entretien doivent être assurés
par un installateur ou un s ervice d’entretien
qualifié ou par le fournisseur de gaz.
Cet appareil peut être installé dans une maison
préfabriquée (mobile) déjà installée à demeure si les
règlements locaux le permettent.
Cet appareil doit être utilisé uniquement avec les types de
gaz indiqués sur la plaque signalétique. Cet appareil ne
peut être converti à d’autres gaz, sauf si une trousse de
conversion est utilesée.
Ne pas utilieser cet appareils il a été plongé, meme
partiellement, dans l’eau. Appeler un technician qualifié
pour inspecter l’appareail et remplacer toute partie du
système de commande et toute commande qui a été
plongée dans / ’eau.
ATTENTION: Au moment de l’entretien des commandes,
étiquetez tous les files avant de les débrancher. Des
erreurs de la câblage peuvent entraîner un fonctionnement
inadequate et dangereux.
S’assurer que l’appareil fonctionne adéquatement une fois
l’entretien terminé.
ATTENTION: Ne pas utiliser l’appareil si la panneau frontal
en verre n’est pas en place, est craqué ou brisé. Confiez le
remplacement du panneau à un technician agree.
Félicitations pour votre achat d’un SÓLAS !
Nous vous souhaitons la bienvenue dans la famille des foyers au gaz SÓLAS. Chacun
de nos produits est habilement conçu et fabriqué de manière experte aux États-Unis.
Nous sommes très fiers de chaque foyer que nous fabriquons. Chaque produit est
entièrement testé tout au long du processus de production pour garantir votre sécurité
et votre chaleur au fil des ans.
Sincèrement,
SÓLAS

solasfires.com 5
IMPORTANT SAFETY INFORMATION
ATTENTION: THIS FIREPLACE IS
DESIGNED AS A WALL-MOUNTED
PRODUCT, THIS FIREPLACE IS NOT TO
BE “BUILT-IN” TO A WALL OR INSTALLED
WITHIN A WALL CAVITY OR ALCOVE. THE
INSTALLATION MUST COMPLY WITH THE
CLEARANCES NOTED ON PAGE 9.
The installation must conform with local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas
and Propane Installation Code, CSA B149.1.
A manufactured home (USA only) or mobile home
OEM installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24
CFR, Part 3280 or when such a standard is not
applicable, the Standard for Manufactured Home
Installations, ANSI/BCSBCS A225.1, or Standard for
Gas Equipped Recreational Vehicles and Mobile
Housing, CSA Z240.4.
The appliance and its appliance main gas valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of ⁄ psi (3.5 kPa).
The appliance must be isolated from the gas supply
piping system by closing its equipment shuto valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than ⁄ psi
(3.5 kPa).
The installation must provide for adequate ventilation
air to the appliance.
This gas appliance must not be connected to a
chimney flue serving a separate solid-fuel burning
appliance.
The appliance, when installed, must be electrically
grounded in accordance with local codes, or, in the
absence of local codes, with the National Electrical
Code ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22. 1.
The appliance area must be kept clear and free from
combustible materials, gasoline and other flammable
vapors and liquids.
The flow of combustion and ventilation air must not
be obstructed. Adequate accessibility clearances
must be maintained for servicing and proper
operation of this appliance.
Do not use this appliance if any part has been under
water. Immediately call a licensed service technician
to inspect the appliance and to replace any part of
the control system and any gas control which has
been under water.
Due to high temperatures, the appliance should be
located out of trac and away from furniture and
draperies.
Children and adults should be alerted to the
hazards of high surface temperatures and should
stay away to avoid burns or clothing ignition.
Young children should be carefully supervised
when they are in the same room as the appliance.
Toddlers, young children and others may be
susceptible to accidental contact burns. A physical
barrier is recommended if there are at-risk
individuals in the house. To restrict access to a
fireplace or stove, install an adjustable safety gate
to keep toddlers, young children and other at-risk
individuals out of the room and away from hot
surfaces.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed for the protection
of children and other at-risk individuals. If the
barrier becomes damaged, the barrier shall be
replaced with the manufacturer’s barrier for this
appliance.
Clothing or other flammable material should not be
placed on or near the appliance.
Any screen or guard removed for servicing an
appliance must be replaced prior to operating the
appliance.

SÓLAS CONTEMPORARY FIRE
6
IMPORTANT SAFETY INFORMATION
Installation and repair should be done by a
licensed service technician. The appliance should
be inspected before use and at least annually by
a professional service technician. More frequent
cleaning may be required due to excessive lint from
carpeting, bedding material, etc. It is imperative that
the control compartments, burners and circulating
air passageways of the appliance be kept clean.
WARNING: Do not operate the appliance with
the glass door assembly removed, or if the glass
is cracked or broken. Replacement of the glass
should be done by a licensed service technician.
WARNING: Use only glass assembly, P/N 26-510,
which includes the glass panel, frame and gasket.
Do not use substitute materials. Do not strike or
slam the glass front. Do not use abrasive cleaners.
Do not clean when hot.
CAUTION: Do not operate with broken glass.
Keep Furniture and
Other Objects
6" from sides and 36"
from front of Fireplace
36" (91.44cm)
Fireplace
6" 6"

7
CERTIFICATION
This appliance has been certified by PFS TECO to ANSI Z21.88-
2016/CSA 2.33-2016 Vented Gas Fireplace Heaters and CAN/
CGA-2.17-2017, Gas-Fired Appliances for Use At High Altitudes.
This SÓLAS Gas Fireplace is approved for installation at
elevations up to 2000 feet in the U.S. and 1370 meters (4500
feet) in Canada without change. If your installation is at an
elevation greater than these, consult with the local authority
having jurisdiction for gas product installations to determine
their specific requirements for high altitude installations.
These appliances are approved for installation in the
Commonwealth of Massachusetts by the Board of State
Examiners of Plumbers and Gas Fitters.
SÓLAS DIRECT VENT GAS FIREPLACES SÓLAS DIRECT VENT GAS FIREPLACES
*Sample Rating Label (axed to Control Panel within Firebox)

SÓLAS CONTEMPORARY FIRE
8
SPECIFICATIONS
INPUT NATURAL GAS PROPANE
Input Rating 19,000 BTU/Hr. 19,000 BTU/Hr.
Min. Input Rating 11,000 BTU/Hr. 11,000 BTU/Hr.
Orifice-DMS 5/64" #55
GAS SUPPLY NATURAL GAS PROPANE
Manifold Pressure High 4.8"w.c. / 1.2kPa 10.0"w.c. / 2.5kPa
Manifold Pressure Low 1.25"w.c. / 0.31kPa 4.2"w.c. / 1.1kPa
Min. Supply Pressure 5.5"w.c. / 1.4kPa 11.0"w.c. / 2.8kPa
Max. Supply Pressure 10.0"w.c. / 2.5kPa 13.0"w.c. / 3.3kPa
EFFICIENCY NG / LP NATURAL GAS PROPANE
Maximum Observed Steady State Eciency - % 78.8 79.5
Steady State Eciency - % 65.0 61.4
Annual Fuel Utilization Eciency (AFUE) - % 64.2 60.5
Canadian p.4 Eciency - % 55.1 50.0
TWENTY6 SPECIFICATION CHART
NOTE: The maximum achievable steady state eciency can vary depending on how
the fireplace is installed and operated.
• It is recommended that the pilot flame be turned o if the appliance will not be in use for an extended
period of time.
• This appliance is equipped for use with the fuel type indicated on the rating plate. Field conversion is only
permitted with a conversion kit supplied by SÓLAS. See page 49 for gas conversion instructions.
This appliance has been certified by PFS TECO to ANSI Z21.88-2016/CSA 2.33-2016 Vented Gas
Fireplace Heaters and CSA-2.17-2017, Gas-Fired Appliances for Use At High Altitudes and CSA P.4.1-09.
The is approved for installation at elevations up to 2000 feet in the U.S. and 1370 meters (4500 feet) in
Canada without change. If your installation is at an elevation greater than these, consult with the local
authority having jurisdiction for gas product installations to determine their specific requirements for
high altitude installations.
TWENTY6 OVERALL DIMENSIONS

solasfi res.com 9
Fireplace Surround to L. Side Wall 6" (152mm)
Fireplace Surround to R. Side Wall 6" (152mm)
Fireplace Surround to Corner Wall 6" (152mm)
Vent Pipe to Adjacent Materials 1.5" (38mm)
Fireplace Surround to Ceiling 8" (203mm)
Fireplace Surround to Rear Wall 0" (0mm)*
Fireplace Surround to Floor 3" (76mm)**
MINIMUM CLEARANCES TO
COMBUSTIBLE CONSTRUCTION
CLEARANCES
Several issues must be addressed when selecting a
suitable location for your TWENTY6 fi replace. The
minimum clearances to combustible construction are
listed below. In addition, access to the gas supply must
be considered. The location of the fi replace will also
a ect the venting requirements and you must be certain
the location will allow compliance with the venting
requirements shown on page 11. You must also insure
that your installation provides adequate accessibility
clearance for servicing and proper operation.
Installation and repair should be done by a licensed
service technician. The appliance should be inspected
before use and at least annually by a professional
service technician. More frequent cleaning may
be required due to excessive lint from carpeting,
bedding material, etc. It is imperative that the control
compartment, burners and circulating air passageways
of the appliance be kept clean.
NOTE: Alcove installation is not permissable.
AA
B B
E
WALLS A = 6" 152 mm
CORNER B = 6" 152 mm
Shown with optional corner Kit)
AIR SPACE
E = ⁄" 9.5mm
Space behind the
Mounting Plate)
C
D
FLOOR
D = 3" 76 mm
CEILING
C = 8" 203 mm
F
F
MANTEL/SHELF F = 8" 203 mm
** The minimum
required
clearance to
be maintained
from the
fi replace to
combustible
fl ooring is
measured from
the top surface
of carpeting,
tile, etc.
* Mounting
plate
bosses
contact
the wall

SÓLAS CONTEMPORARY FIRE
10
The gas fireplace is shipped with a ⁄" tube OD (male
flare) connection. The gas supply piping should have a
separate gas shuto valve and a ⁄" NPT plugged tapping
upstream of the valve. The stove and its main control
valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test
pressures in excess of ⁄ psi (3.5 kPa). The stove must be
isolated from the gas supply piping system by closing the
main control valve during any pressure testing of the gas
supply system at test pressures equal to or greater than
⁄ psi (3.5 kPa). After the gas supply has been connected,
use a commercial gas leak detector or apply a soapy water
solution to all the fittings to check for gas leaks. Never use
a flame to test for leaks.
A COPY OF THESE INSTRUCTIONS PLUS ALL
VENTING INSTRUCTIONS WHICH INCLUDE
PARTS LISTS, AND/OR ALL VENTING DESIGN
INSTRUCTIONS MUST REMAIN WITH THE STOVE AT
THE COMPLETION OF THE INSTALLATION.
ATTENTION INSTALLERS: Mark below which venting
system was used in the installation. These instructions
must remain with the SÓLAS Gas Fireplace Installation
& Operation Manual.
O Simpson DuraVent GS/PRO®
O Selkirk Direct-Temp®
O Security Secure Vent™
O AmeriVent Direct™
O Metal Fab Direct Vent
O ICC Direct Vent
NOTICE
Failure to follow these instructions will void the
warranty.
INSTALLATION REQUIREMENTS
STATE OF MASSACHUSETTS
The installation must be completed by a licensed
plumber or gas fitter in the Commonwealth of
Massachusetts.
REQUIREMENTS FOR THE COMMONWEALTH OF
MASSACHUSETTS
This product must be installed by a licensed plumber
or gas fitter when installed within the Commonwealth
of Massachusetts. If this appliance is installed in a
dwelling, building or structure used in whole or in part
for residential purposes and the installation includes a
horizontal vent termination that is less than seven (7)
feet above the finished grade in the area of the venting,
including but not limited to decks and porches, a hard-
wired carbon monoxide detector with an alarm and
battery back-up must be installed on the floor level of the
dwelling, building or structure where the appliance is to
be installed.
Additionally, a hard-wired or battery operated carbon
monoxide detector with an alarm must be installed
on each additional level of the dwelling, building
or structure served by the appliance. It shall be the
responsibility of the property owner to secure the
services of licensed licensed professionals for the
installation of hard-wired carbon monoxide detectors.
In the event that the horizontally vented appliance is
installed in a crawl space or attic, the hardwired carbon
monoxide detector with alarm and battery back-up may
be installed on the next adjacent floor level.
In the event that this requirement cannot be met at the
time of completion of the installation of the appliance,
the owner shall have a period of thirty (30) days to
comply with the requirement. However, during said thirty
(30) day period, a battery operated carbon monoxide
detector with alarm must be installed.
Each carbon monoxide detector as required in
accordance with the above provisions must comply with
NFPA 720 and be ANSI/UL 2034 and IAS certified.
In addition, when the vent termination is less than
seven (7) feet above finished grade a metal or plastic
identification plate must be permanently mounted to the
exterior of the building at a minimum height of eight (8)
feet above grade directly in line with the exhaust vent
terminal. The sign shall read, in print size no less than
one-half (⁄) inch in size, “GAS VENT DIRECTLY BELOW.
KEEP CLEAR OF ALL OBSTRUCTIONS".
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Chimenea de interior de Solas

Solas
Solas FIN-36N Manual de usuario

Solas
Solas TWENTY6 SL-26N Manual de usuario

Solas
Solas TWENTY6 ST-26N Manual de usuario

Solas
Solas SEVENTY2 LGS-72 Manual de usuario

Solas
Solas SIXTY0 LGS-60 Manual de usuario

Solas
Solas COOL ZONE Manual del propietario

Solas
Solas THIRTY8 Series Manual de usuario

Solas
Solas FORTY6 SLIM-LINE Manual de usuario

Solas
Solas BI-48-ST Manual de usuario

Solas
Solas TWENTY6 SLIM-LINE Manual de usuario