Solas SCPV-900C Manual de usuario

THIS POWER VENT KIT IS ONLY FOR USE WITH THE FOLLOWING S
Ó
LAS MODELS:
SL-16N, SL-16P, SL-26N, SL-26P, ST-46N, ST-46P, FS-16N-RV, FS-16P-RV, FS-16N-TV, FS-16P-TV, BI-38N-C, BI-38P-C,
BI-38N-T, BI-38P-T, BI-48-SSL, BI-48-SSR, BI-48-ST, BI-60-SSL, BI-60-SSR, BI-60-ST, BI-72-SSL, BI-72-SSR, BI-72-ST
SELF
SELFSELF
SELF-
--
-CALIBRATING
CALIBRATINGCALIBRATING
CALIBRATING
POWER
POWERPOWER
POWER
VENT
VENTVENT
VENT
CONTROL
CONTROLCONTROL
CONTROL
AND
ANDAND
AND
TERMINATION
TERMINATIONTERMINATION
TERMINATION
KIT
KITKIT
KIT
Ce manual est disponsible en Francais sur
demande.
SCPV-900C SHOWN
SÓLAS STRONGLY SUGGESTS T AT YOU READ T IS
MANUAL T OROUG LY BEFORE BEGINNING T E
INSTALLATION OF T E SÓLAS POWER VENT KIT. T IS
SPECIFIC PRODUCT AS ITS OWN UNIQUE SET-UP AND
INSTALLATION REQUIREMENTS T AT MUST BE
FOLLOWED EXACTLY. PLAN YOUR INSTALLATION IN
ADVANCE BY CAREFULLY RE-VIEWING ALL T E
INFORMATION CONTAINED IN T IS MANUAL.
WARNING: ALL INSTALLATION, SERVICING, AND
TROUBLESHOOTING MUST BE PERFORMED BY A
QUALIFIED GAS TECHNICIAN.


2
TABLE OF CONTENTS
SÓLAS Power Vent Components 3
SÓLAS Power Vent Terminations 4
Flush-mount Termination specifications 6
Surface-mount Termination specifications 7
Power Vent Clearances 8
Venting Configurations 9
Flush Mount (side wall) Installation 10
Surface Mount (side wall) Installation 11
Vertical (thru the roof) Installation 12
Installation Instructions 14
Electrical Instructions 16
Calibration and Operation 17
Troubleshooting 20
Replacement Parts List 22
Warranty Information 23
WARNING:
This inst ll tion m nu l covers the function l
requirements for optim l perform nce of your
firepl ce with power vent inst ll tion, consult with
profession l rchitect, civil engineer, or home
builder reg rding the building code, esthetic nd
NOTE:
SÓLAS dvises th t the ppli nce inst ll tion should
be c libr ted, tested, nd the firepl ce burned to
ensure optim l perform nce nd desired fl me
esthetics BEFORE the vent system or firepl ce re
enclosed nd w lls or ceilings re finished.

3
SÓLAS POWER VENT COMPONENTS
SCPV-900C - Self-Calibrating Power Vent Control
Module, required for all power vent installations.
SCPV-905PS - Self-Calibrating Power Vent Pressure
Switch, required for all power vent installations. Only
use the pressure switch certified by SÓLAS with the
SÓLAS Self-Calibrating Power Vent Control. Connect
to pressure port using the 12ft length of ¼” ID silicon
tubing (not shown) supplied with the Self-Calibrating
Powervent control kit.
SCPV-91 GS - Self-Calibrating Power Vent Gas
Solenoid, required for all power vent installations.
Only gas solenoids certified for use by SÓLAS are to be
used with the SÓLAS Self-Calibrating Power Vent
Control.
SCPV-12218-XX - Self-Calibrating Power Vent
termination wire harness, required for all power vent
installations. The termination wire harness is
available in 25, 50, 100, and 150 lengths.
Harness Part # Description
SCPV-12218-25 Termination Wire arness, 25FT long
SCPV-12218-50 Termination Wire arness, 50FT long
SCPV-12218-100 Termination Wire arness, 100FT long
SCPV-12218-150 Termination Wire arness, 150FT long

4
SÓLAS POWER VENT TERMINATIONS
SCPV-9 6DVA - Self-Calibrating Power Vent Pressure
Port Vent Adapter, required with terminations SCPV-
160FM, SCPV-459SM, and SCPV-459TV.
NOTE: This adapter, based on M&G Duravent’s 46DVA-
06 directvent pipe, should be installed immediately on
the starter collar of the fireplace. For SÓLAS fireplaces
requiring a 45° elbow immediately following the
starter, this adapter should be installed immediately
following the 45° elbow.
SCPV-160FM - Self-Calibrating Power Vent Flush-
Mount Termination, for use with vent runs over 10 feet
in length, regardless of the number of elbows in the
vent configuration. This termination requires the use
of SCPV-946DVA - Self-Calibrating Power Vent Pressure
Port Vent Adapter.
SCPV- 59SM - Self-Calibrating Power Vent Surface-
Mount Termination, for use with vent runs over 10 feet
in length, regardless of the number of elbows in the
vent configuration. This termination requires the use
of SCPV-946DVA - Self-Calibrating Power Vent
Pressure Port Vent Adapter.
SCPV- 59SM-10 - Self-Calibrating Power Vent
Surface-Mount Termination, for use with vent runs
under 10 feet in length, regardless of the number of
elbows in the vent configuration. This termination is
Not to be used with SCPV-946DVA - Self-Calibrating
Power Vent Pressure Port Vent Adapter.
NOTE: This termination can be differentiated from
SCPV-459SM by the addition of the pressure port on
the rear top-left corner of the termination.
PRESSURE PORT

5
SÓLAS POWER VENT TERMINATIONS
SCPV- 59TV - Self-Calibrating Power Vent Vertical
Termination, for use with vertically terminating vent
runs only. This termination requires the use of
SCPV-946DVA - Self-Calibrating Power Vent Pressure
Port Vent Adapter.
The SOLAS Self-Calibrating Power vent kit can only be used in conjunction with the SÓLAS
Contemporary Fire products listed below. This installation must conform with local codes, or, in the
absence of local codes, with the National Fuel Gas Code, ANSIZ2223.1/NFPA 54, or the Natural Gas and
Propane Installation Code, CSA B149.1.
THIS POWER VENT KIT IS ONLY FOR USE WITH THE FOLLOWING SÓLAS MODELS:
SL-16N, SL-16P, SL-26N, SL-26P, ST-46N, ST-46P, FS-16N-RV, FS-16P-RV, FS-16N-TV, FS-16P-TV, BI-38N-C, BI-38P-C,
BI-38N-T, BI-38P-T, BI-48-SSL, BI-48-SSR, BI-48-ST, BI-60-SSL, BI-60-SSR, BI-60-ST, BI-72-SSL, BI-72-SSR, BI-72-ST
This kit uses either M&G Duravent direct vent pipe, Secure Vent direct vent pipe, or Selkirk Direct-
temp vent pipe with a ” inner pipe and a 6-5/8” outer pipe.
Vertical installations must use the SCPV- 59TV vertical termination. The vertical termination can
only be installed on flat surfaces; sloped surfaces require construction of a chase which provides the
minimum interior square opening of 11.9”x12.9” (302mm x 328mm) for the venting and wiring to pass
through. Flat roofs may require a chase depending on local codes and roof construction. (If in doubt
check with your local inspector)
ALWAYS MAINTAIN T E REQUIRED 1.5” (38mm) CLEARANCE TO COMBUSTIBLES AND ELECTRICAL
WIRING AROUND VENT PIPE.
The location of the Power Vent termination must be in accordance with the clearances outlined in the
venting section of this manual on page 8.
For replacement parts, refer to page 22. Replacement parts can be ordered through your authorized
SÓLAS dealer.

6
FLUSH-MOUNT TERMINATION SPECIFICATIONS
SCPV-160FM - Self-Calibrating Flush-Mount Power Vent Dimensions:
SCPV-160FM - Self-Calibrating Flush-Mount Power Vent Cavity Dimensions:
NAILING FLANGE
FLUE OUTLET

7
SURFACE-MOUNT TERMINATION SPECIFICATIONS
SCPV- 59SM - Self-Calibrating Surface-Mount Power Vent Dimensions:
SCPV- 59SM - Self-Calibrating Surface-Mount* Power Vent Cavity Dimensions:
*These dimensions apply to SCPV-459SM and SCPV-459SM-10, see page 12 for SCPV-459TV
FLUE OUTLET
NAILING FLANGE
PRESSURE PORT

8
POWER VENT CLEARANCES
Figure #1
A. clearances above grade, veranda, porch, deck, or balcony [*12 inches (30 cm) minimum]
B. clearance to window or door that may be opened [* 12 inches (30 cm) minimum]
C. clearance to permanently closed window [minimum 12 inches (30 cm) recommended to prevent condensation on
window]
D. vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm)
from the edge of the terminal [12 inches (30 cm) minimum]
E. clearance to unventilated soffit [12 inches (30 cm) minimum]
F. clearance to outside corner [6 inches (15 cm) minimum]
G. clearance to inside corner [6 inches (15 cm) minimum]
H. * not to be installed above a meter/regulator assembly within 3 feet (90 cm) horizontally from the center-line of
the regulator
I. clearance to service regulator vent outlet [* 6 feet (1.8 m) minimum]
J. clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance [* 12
inches (30 cm) minimum]
K. clearance to a mechanical air supply inlet [* 6 feet (1.8 m) minimum]
L. ^ clearance above paved side-walk or a paved driveway located on public property [* 7 feet (2.1 m) minimum]
M. clearance under veranda, porch, deck, or balcony [12 inches (30 cm) minimum**]
^ a vent shall not terminate directly above a side-walk or paved driveway which is located between two single family
dwellings and serves both dwellings*
** only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor*
* as specified in CGA B149 Installation Codes, Note: local Codes or Regulation may require different clearances
* for U.S.A. Installations follow the current National Fuel Gas Code, NSI Z223.1

9
VENTING CONFIGURATIONS
Maximum vent length is 130 ft.
Up to eight 90° elbows or
combination of other elbows
equaling 90° are permitted, for
each 90° elbow, 3 ft must be
deducted from the 130 ft
maximum vent length. with a
maximum 66ft vertical rise. Each
90° elbow is equivalent to 3 feet
of venting. Minimum horizontal
vent length is 3 ft. The vent can
be installed with any
combination of rise and run
between the figures including up
to 6 ft. of downward venting.
Figure #2
WARNING:
A minimum clearance to combustibles and electrical wiring of 1.5” (38mm) is required around the
vent pipe at all times. Failure to maintain this clearance may result in property damage, injury, or
death.
NOTE: The vent pipe must engage the power vent termination by at least 1.5” (38mm) to ensure the
vent system is intact. Seal the joint with foil tape and self-tapping sheet metal screws (included).
Figure #3
NOTE: IT IS PERMISSIBLE TO VENT ORIZONTALLY, DIRECTLY OFF OF T E UNIT, NO VERTICAL RISE IS
REQUIRED W EN EQUIPPED WIT A POWER VENT AS S OWN IN FIGURE #3.
M ximum venting
–
130ft
including (8) 90
°
elbows.
Vertic l termin tions
require the use of
SCPV-459TV
M x 6ft downw rd
venting permitted
Este manual sirve para los siguientes modelos
6