Solar Storm SS48ST Manual de usuario

SS48ST Commercial Tanning Booth

Solar Storm warrants all of our indoor suntanning equipment to be
free from defects in workmanship as follows:
LPI’s obligation under this warranty is limited to the repair and/or replacement of any defective part
without charge for that part, at LPI’s discretion, with the following limitations:
This warranty is extended only to the original purchaser appearing on the sales receipt and
is non-transferable.
This product is designed for use by one person at a time.
Only original OEM parts may be used.
All major repairs must be completed by an authorized service representative.
This warranty does not cover transportation charges on the parts.
Labor costs are not reimbursable for repair or replacement of items.
LPI disclaims any responsibility for transportation. LPI further disclaims any responsibility for injury
resulting from the failure of equipment or parts manufactured by LPI due to incorrect installation or
operation.
LPI shall not be liable for loss or damages caused either directly or indirectly from the use of its
products. This limited warranty does not extend to any products which have been damaged as a result of
accident, misuse, abuse, or as a result of service or modification by anyone other than an LPI
representative.
This warranty does not apply to any failure of parts or products due to alterations, modifications, misuse,
abuse, accidents, improper maintenance, or failure to follow the specified electrical requirements. Such
occurrences immediately VOID this warranty. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL
OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF
MERCHANTABILITY. No person, firm, or corporation is authorized to assume for us any other
liability in connection with the sale of these goods
THIS PRODUCT IS IN CONFORMITY WITH PERFORMANCE STANDARDS
FOR SUN LAMP PRODUCTS PER 21CFR878.4635 AND 21CFR1040.20. AS A
RESULT, THIS PRODUCT MUST BE USED IN CONJUNTION WITH
21CFR1040.20 APPROVED EYEWEAR AND COMPONENTS.
Serial numbers are located on the rails at the rear of the booth.
Commercial Tanning Bed Warranty
• 36 Months on parts- Including: Ballast, Contactors, & Timers.
• 6 Months on Acrylic
• 90 Days on Gas Springs
• 90 Days on Lamps
• 180 Days on Labor

2655 Inferno 160X 160w
Disconnect power cord before attempting to clean, re-lamp, or
engage in the maintenance of this product. This equipment must
be earth grounded.
DO NOT operate the tanning booth while wet or near water.
Solar Storm Tanning Booth Specifications/Info.
Model
Size
HxW”
Weight
(lbs.)
Voltage
(Volts)
Amps
(Rated)
Dedicated
Breaker
Amps
NEMA
Receptacle
Timer*
Solar
Storm
36
77x48
375
240
41 50
N/A - Hard-
Wired
See Electrical
Requirements
Digital
Danger: Ultraviolet radiation. Follow instructions. Avoid overexposure. As with natural
sunlight, overexposure can cause eye and skin injury and allergic reactions. Repeated exposure may
cause premature aging of the skin and skin cancer. WEAR PROTECTIVE EYEWEAR; FAILURE
TO MAY RESULT IN SEVERE BURNS OR LONG-TERM INJURY TO THE EYES.
Medications or cosmetics may increase your sensitivity to the ultraviolet radiation. Consult
physician before using sunlamp if you are using medications or have a history of skin problems or
believe yourself especially sensitive to sunlight. If you do not tan in the sun, you are unlikely to tan
from the use of this product.
Persons under the age of 18, the elderly, or fair skinned people who always burn easily and either
never tan or tan minimally should not use this equipment.
Untanned persons should not tan on consecutive days during their first week of tanning. Never tan
more than once a day. Tanning normally appears after the first few sessions and maximizes after
approximately four weeks. Tan once or twice per week thereafter to maintain appearance. Persons
already having a base tan may begin at advanced levels corresponding to the extent of their base tan.
Intended use statement: The LPI tanning beds and booths are indicated for the tanning of human
skin via ultraviolet light.
THIS PRODUCT IS IN CONFORMITY WITH PERFORMANCE STANDARDS
FOR SUN LAMP PRODUCTS PER 21CFR878.4635 AND 21CFR1040.20. AS A
RESULT, THIS PRODUCT MUST BE USED IN CONJUNTION WITH
21CFR1040.20 APPROVED EYEWEAR AND COMPONENTS.

Pre-Installation Planning
Before you begin to assemble your tanning booth, please read the following information.
Electrical Requirements
Your Solar Storm tanning booth will need to be hard-wired to a 50A circuit.
A qualified electrician will be needed to assist in fulfilling these requirements
per your local code.
ALL IMPROPER VOLTAGES MUST BE RECTIFIED WITH THE
CORRECT BUCK BOOSTER TRANSFORMER!
Failure to comply with Solar Storm’s electrical requirements will
VOID ALL WARRANTIES and will damage electrical components!
VERY IMPORTANT!
MUST READ!
Your Solar Storm Tanning Booth 240 Volt Model
REQUIRES a 50 Amp DEDICATED Circuit Breaker.
This means that your tanning booth is the ONLY
electrical device operating on that circuit breaker.
Additionally a very easy way of protecting your tanning booth
from potential electrical damage due to power surge or spikes is
to disconnect the unit when NOT in use.

This page intentionally left blank.

Solar Storm Tanning Booth Location Requirements
Make sure the room is well ventilated. Air from the room is used to cool your tanning booth, which
helps to ensure years of trouble free performance. Poor ventilation may cause the unit to overheat
and cause discomfort to the user as well. Place your tanning booth no closer than one foot from any
wall. Be sure that curtains, drapes, and other room furniture is not obstructing the airflow into the
end caps of the booth or out of the fan openings. Due to the nature of the booth, it is best to place it
in a corner, allowing enough room for the door to swing open.
Unpacking Instructions
Your tanning booth comes in three cardboard cartons: two for the stationary sections and one
for the door section.
Remove the three sections from the plastic bags. The door box contains the hardware box.
Inspect all items thoroughly for any visible damage. Report any such damage to your
Solar Storm Authorized Dealer immediately.
BOOTH ASSEMBLY INSTRUCTIONS
Proper assembly of your tanning booth requires two people.
Tools required – In addition to the supplied hex key, assembling the tanning booth requires an
adjustable wrench.
Parts List
Included Hardware
Item
Description
Quantity
A
Stationary Hinge
2
B
Bottom Door Hinge
1
C
Top Door Hinge
1
D
5/16 x 1 ½ Allen Bolt
8
E
Leveler
4
F
Caster
2
G
Allen Wrench
1
H
Leveler Nut
4

Included Hardware (continued)
Attaching Hinge to Bottom of Sections 1 and 2 – Figure 1a
Step 1. Lay sections one and two next to each other on a soft material (i.e. carpet) with the lamps
facing down, and with the male and female power cords aligned. Section one contains the timer and
main power cord. Section 2 has the short, inter-connecting power cords on both sides.
Step 2. Thread nuts “H” onto the levelers “E” then thread the leveler shafts into the end cap holes “3”
as shown in figure 1a. so that they protrude about 2 inches. Snug the nuts against the end caps. If
necessary, use an adjustable wrench on the levelers at the base of the threaded portion. DO NOT
OVER-TIGHTEN! BE CAREFUL NOT TO STRIP THE THREADS!
Step 3. During this step, make sure that the inter-connecting power cords are securely connected. Do
not pinch the cords between the rails of the two different sections. Have one person at the top end of
the unit, and another person at the bottom end. Both people need to raise the units in the center where
they meet in order to insert the guide bolts of hinge “A” into the “1” holes of the end caps at the
bottom end of the unit. The person at the top end of the unit can hold the two units up in position,
while the person at the bottom end threads bolts “D” through hinge “A” into the “2” holes of the end
caps. Use the supplied allen wrench to tighten these bolts. DO NOT OVER-TIGHTEN! Continue
supporting the two sections through the next step.

Attaching Hinge to Top of Sections 1 and 2 – Figure 1b
Step 1. Align the guide bolts of hinge “A” through the “1” holes in the end caps at the top end of the
units as shown in figure 1b.
Step 2. Thread bolts “D” through hinge “A” into the “2” holes of the end caps, and tighten with the
supplied allen wrench. DO NOT OVER-TIGHTEN!
Hard-
Wire

Attaching the Door to Bottom of Section 2 – Figure 1c
Step 1. Thread the casters “F” into the “3” holes in the end caps as shown in figure 1c. Tighten
with the adjustable wrench. DO NOT OVER-TIGHTEN!
Step 2. Align the guide bolt of hinge “B” through the “1” hole in the end cap at the bottom of
section 2.
Step 3. Thread one of the “D” bolts through hinge “B” into the “2” hole of section 2.
Step 4. Have one person hold the joined sections 1 and 2 in position to allow the other person to
thread the next “D” bolt through hinge “B” into hole “2” of section 3. Tighten the bolts with the
supplied allen wrench. DO NOT OVER-TIGHTEN!
Hard-
Wire

Attaching the Door to Top of Section 2 – Figure 1d
Step 1. During this step, make sure you do not pinch the cords between the rails of the two different
sections. Align the guide bolt of hinge “C” through the “1” hole in the end cap at the top end of
section 2 as shown in figure 1d.
Step 2. Thread bolts “D” through hinge “C” into the “2” holes of the end caps at the top end of
sections 2 and 3, and tighten with the supplied allen wrench. DO NOT OVER-TIGHTEN!
Now CAREFULLY position the unit upright by lifting the top end while securing the door so that it
does not swing open in the process. At this time, push the booth into its permanent location. Tighten
and/or loosen the levelers and nuts as necessary with an adjustable wrench to ensure proper footing of
the unit. The best spot to use an adjustable wrench on the levelers is at the base of the threaded stem.
BE CAREFUL NOT TO STRIP THE THREADS!
Making the Electrical Connection – refer to electrical requirements, page 5.
WARNING! Be sure electrical power is disconnected before connecting the
male/female inter-connecting cables.
Step 1. Securely connect all inter-connecting power cords that run between the three sections of the
unit.
The main power connection needs to be hard-wired by an electrician per the Electrical Requirements.
DO NOT CONVERT THE POWER CORD TO A TWO OR THREE PRONG
CORD, MODIFY THE CORD IN ANY WAY, OR USE ANY EXTENSION
CORD.
ENSURE THAT THE POWER CORD IS ROUTED SAFELY AWAY FROM
TRAFFIC AND/OR ANY HAZARDS.
AS RECOMMENDED FOR ALL ELECTRICAL APPLIANCES, THIS
TANNING BOOTH SHOULD NEVER BE OPERATED NEAR WATER
OR WHILE YOU ARE WET.
Tabla de contenidos