Warranty
C A U T I O N
DO NOT ATTEMPT TO SERVICE THE UNIT BY REMOVING
THE COVER. REMOVAL OF THE UNIT COVER WILL VOID
THE WARRANTY. CALL THE SERVICE CENTER.
SMK Industries warrants this product to be free from
material or workmanship defects for a period of 60 days
from the date of manufacture. Alternatively, 60 days from
purchase, not to exceed one year from date of
manufacture.
Warranty does not apply when:
Unit is not used within the guidelines of this
manual.
Product or Parts are used or installed outside
the SMK authorized service center.
Incompatible fluids are used.
Misuse or Abuse.
Improper or inadequate cleaning of unit after
use.
In the event you need to utilize this warranty, the product or
part must be returned for examination, postage prepaid,
direct to the SMK Industries service center as instructed by
calling 515-202-0052. Proof of purchase date and an
explanation of the claim must accompany the
merchandise. If inspection discloses a defect, SMK will
either repair or replace the product with like equipment at
SMK’s expense. If no defect is found during the
inspection, or if the defect resulted from causes not within
the scope of SMK’s limited warranty, then the user must
assume all costs incurred returning and/or storing the
product.
All products and parts will be tested using SMK testing
criteria. Units found to be damaged, altered or otherwise
mistreated will not be covered under this warranty. Units
found not to be defective are subject to charges to be paid
by the returnee. Page 5
Operating the Sprayer
Keeping all safety and operating measures in mind you are
now ready to begin spraying.
4. Prime the Sprayer
a. Squeeze the Spray Gun Handle
b. Turn the Power Switch On (depress white square)
c. The Pump is self priming and should begin spraying
in a few seconds.
d. IMPORTANT - When Power Switch Light starts
flickering (pump is cycling on and off), turn the
Speed Control down (counterclockwise) until the
light is steady on (pump is not cycling on and off).
e. After liquid is flowing and all air is purged from the
lines, release the Handle and the Sprayer will turn
off.
f. If the pump does not prime within 20 seconds, turn
off the power and check to see that all fittings are
tight and the Intake Filter is not clogged.
g. Running the Pump dry over 1 minute will destroy the
gears and void the warranty.
The pump is designed for continuous duty when proper
operating criteria are met.
C A U T I O N
BEFORE REMOVING THE SPRAY HOSE, TURN THE
POWER OFF AND RELIEVE ANY PRESSURE IN THE
SPRAY HOSE BY SQUEEZING THE SPRAY HANDLE.
Page 10