SmartVent Lite+ Manual de usuario

HOME VENTILATION SYSTEMS
Firmware Version 3.4
User Manual
Your guide to a healthier home

Warning
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- Isolate the mains supply before attempting to replace the system’s air filter.

3
SmartVent Lite+ System
Firmware Version 3.4
Contents
Home Screen Icons..................................................................................................................... 4
Button Functions......................................................................................................................... 4
Screen Highlights........................................................................................................................ 5
Modes
Auto Operation and Temperature Setting ................................................................................. 5
Manual Operation and System Fan Speed Setting.................................................................... 5
Boost .................................................................................................................................... 6
Recycle................................................................................................................................. 6
Fan OFF Setting..................................................................................................................... 6
Key Lock Setting.................................................................................................................... 6
Relative Humidity ........................................................................................................................ 7
Dew Point................................................................................................................................... 7
System Time-Date Settings.......................................................................................................... 8
System Operating Settings
Scheduler Settings................................................................................................................. 9
Period OFF/ON Settings........................................................................................................ 10
Period Schedule Log............................................................................................................ 11
Advanced Settings
Advanced Settings Selection................................................................................................. 11
Advanced Settings Menu...................................................................................................... 12
Troubleshooting ........................................................................................................................ 13
Technical Specifications ............................................................................................................ 14

4
Home Screen Icons
System Fan Speed
Ventilation Mode 1)
Air Source Indicator
Recycle ON
Temperature Sensing ON
Dew Control Mode ON
Dew Point Temperature
Home and Power
Settings
Up
Select
Down
Set 2)
Fresh Air Temperature 2) or
Fresh Air Relative Humidity 3)
Current Room Temperature or
Current Room Relative Humidity 4)
Key Lock ON
Rental Mode ON 5)
Alert 6)
Time 7)
Scheduler Period and Day
Yellow highlight
indicates icon
is flashing
Green highlight
indicates button(s)
to push
Button Functions
Power OFF/ON or discard selections and return to Home Screen
From Home Screen enter setting screen or return to previous setting option
Scroll through setting options and change setting values
Save setting selection and go to next setting option
Screen Highlights
1) Ventilation mode selections are AUTO or MAN (manual)
2) The SET icon will appear when the temperature is being changed and the
progressive temperature changes being made will be displayed instead of
the Fresh Air temperature
3) Relative Humidity value is showing if the °C symbol is not displayed
4) Relative Humidity value is showing if the percentage % symbol is
displayed instead of the °C symbol.
5) When RENTAL mode is ON, fan OFF setting and Scheduler is disabled
6) When an electronic fault in the system occurs, the alert icon will appear
and the applicable error code(s) will be displayed instead of the time
7) Time is displayed in a 24 hour clock format

5
Confirm
MAN
operation
Go to
FAN SPEED
value
Select
FAN SPEED
value
Save all
settings
Go to
Home
Screen
Confirm
AUTO
operation Select
TEMP
value
Go to
TEMP
value
Save all
settings
Go to
Home
Screen
Modes
Auto Operation and Temperature (TEMP) Setting
Your SmartVent Lite+ system can choose at what speed to draw air depending on the indoor and outdoor air
temperatures, when in AUTO. If the system is in either BOOST or RECYCLE modes, the fan will, instead, operate at
the speeds set for those particular modes.
You select the SET temperature you want it to be in the home (ie. 22°C (default)) and the system will work on the
best air source to achieve your SET temperature 1).
For example, if you set your system to 20°C while the current house temperature is 18.3°C, the control system
measures the incoming air temperature and alters the fan speed to suit. If the incoming air temperature is
20°C or higher, the fan will operate at a high speed to use the free heat to try and increase the overall house
temperature. If lower than 20°C, the fan speed would decrease to reduce the cooling effect 2).
- On the Home Screen, press SETTINGS and then UP , or DOWN , to toggle to ON
- Press SELECT to enter VENTILATION mode
- Press UP , or DOWN , to toggle to AUTO operation and follow the guide below to adjust the temperature
setting.
- Alternately, if already in ON and on the Home Screen, press SELECT to toggle directly to AUTO operation
and follow the same guide below to adjust the temperature setting.
1) Your system is not a heating or cooling device. This parameter is designed to reduce nuisance over-heating or over-cooling of your home.
2) Additional features are available when low temperatures are present. See RECYCLE mode.
Manual (MAN) Operation and System Fan Speed and Air Source Settings
Your SmartVent Lite+ system allows manual control of the fan speed if required. Fan speed will remain constant
at the speed set. If the system is in either BOOST or RECYCLE modes, the fan will, instead, operate at the speeds
set for those particular modes.
- On the Home Screen, press SETTINGS and then UP , or DOWN , to toggle to VENTILATION mode
- Press SELECT to enter VENTILATION mode and then UP , or DOWN , to toggle to MAN operation and
follow the guide below to complete the setting of the system fan speed and the selection of the air source.
- Alternately, if already in ON and on the Home Screen, press SELECT to toggle to MAN operation and
follow the same guide below to change the system fan speed.

6
Modes
Boost
BOOST enables you to immediately override fan speed settings and boost fan speed to maximum.
- On the Home Screen, press SELECT for 3 seconds and system’s fan will boost to maximum speed.
- In BOOST mode, the time segments will become a count down to the end of the BOOST mode.
- A quick tap of SELECT on the Home Screen will exit BOOST mode.
Tap to Exit3 seconds
Recycle
RECYCLE is designed for environments where extremes of temperature are common. When your system is in
VENTILATION mode and the roof cavity temperature exceeds the maximum roof cavity temperature (default =
30ºC) setting, or goes below the minimum roof cavity temperature (default = 5ºC) setting, your SmartVent system
will limit the amount of air entering your home.
RECYCLE icon will be displayed when your system is in RECYCLE mode. In Advanced Setting Menu, RECYCLE
mode can be disabled (setting 007), Recycle Speed can be adjusted (setting 008) and temperature settings can
be adjusted (settings 009 and 010). The fan will operate on Recycle Speed (default = OFF) during RECYCLE mode.
Display
RECYCLE
speed
Key Lock Setting
When Key Lock is ON, system settings cannot be changed
- Press UP and DOWN together for 3 seconds, until the KEY LOCK icon is displayed, to confirm that
the system is locked.
- Press UP and DOWN together for 3 seconds, until the KEY LOCK icon is not displayed, to confirm
that the system is unlocked.
Fan OFF Setting
- On the Home Screen, press SETTINGS and then UP , or DOWN , to toggle to OFF
- Press SELECT to save the fan OFF setting.

7
Relative Humidity
The current Relative Humidity percentages in the roof cavity and the room can be viewed at any time.
- On the Home Screen, press UP , or DOWN , for 3 seconds to display the Relative Humidity percentages
in both the roof cavity and the room
- The display will automatically return to the Home Screen after 3 seconds
Return to
Home
Screen
3 secs
delay
Dew Point
The current Dew Point temperatures in the roof cavity and the room can be viewed at any time.
- On the Home Screen, press UP , or DOWN , for 3 seconds to display the Relative Humidity percentages
in both the roof cavity and the room
- Within 3 seconds after the Relative Humidity percentages are displayed, press UP , or DOWN , again for
3 seconds to display the Dew Point temperatures in both the roof cavity and the room
- The display will automatically return to the Home Screen after 3 seconds
Press UP or DOWN
for 3 secs to go to
HUMIDITY
screen
Return to
Home
Screen
3 secs
delay
Press UP or DOWN
for 3 secs to go to
DEW POINT
screen

8
System Time-Date Settings
System Time-Date Settings must be entered before system functions, such as scheduled start times, can be set.
- On the Home Screen, press SETTINGS for 3 seconds to enter Time-Date Settings and follow the guide
below to complete
NOTE: Settings shown are examples only
- Press HOME at any stage to exit and enter Scheduler Settings
- Press SETTINGS at any stage to return to the previous screen
Select
MONTH
value
Go to
DAY DATE
value
Select
DAY DATE
value
Save all
TIME-DATE
settings
Go to
SCHEDULER
settings
Select
DAY
value
Go to
YEAR
value
Confirm
DAY
value
Select
HOUR
value
Go to
MINUTE
value
Confirm
HOUR
value
Confirm
MONTH
value
Select
MINUTE
value
Go to
DAY
value
Confirm
MINUTE
value
Select
YEAR
value
Go to
MONTH
value
Confirm
YEAR
value

9
System Operating Settings
Scheduler Settings
Setting the Scheduler is only necessary if you wish to control whether the system is OFF or ON during each of the
four periods available in a 24 hours period.
A period start time is also the previous period end time.
- On the Home Screen, press SETTINGS for 3 seconds then press HOME to enter Scheduler Settings and
follow the guide below to complete
NOTE: Settings shown are examples only
- Press HOME at any stage to exit Scheduler Settings and return to the Home Screen
- Press SETTINGS at any stage to return to the previous screen
Period 1 Period 2 Period 3 Period 4
Go to
MINUTE
value
Select
MINUTE
value
Go to
PERIOD 2
Select
HOUR
value
Go to
MINUTE
value
Select
MINUTE
value
Go to
PERIOD 3
Select
HOUR
value
Go to
MINUTE
value
Select
MINUTE
value
Go to
PERIOD 4
Select
HOUR
value
Go to
MINUTE
value
Select
MINUTE
value
Go to
Home
Screen
Select
HOUR
value
Confirm
HOUR
value
Confirm all
PERIOD 1
settings
Confirm
HOUR
value
Confirm all
PERIOD 2
settings
Confirm
HOUR
value
Confirm all
PERIOD 3
settings
Confirm
HOUR
value
Save all
PERIOD 1-4
settings

10
System Operating Settings
Period OFF/ON Schedule
Set VENTILATION mode to AUTO operation (see page 5).
Fan speed will adjust automatically based on the Dew Point and then indoor/outdoor air temperatures. If system is
in either BOOST or RECYCLE modes, the fan will operate at speeds set for those modes.
- On the Home Screen, press SETTINGS to enter Period OFF/ON Schedule and follow the guide below to
complete the fan OFF/ON settings for each of the four periods available in a 24 hour period.
NOTE: Settings shown are examples only and OFF periods should only be scheduled if absolutely necessary.
- Press HOME at any stage to exit Period OFF/ON Schedule and return to the Home Screen
- Press SETTINGS at any stage to return to the previous screen
Select
SCHEDULE
(SCH)
Go to
PERIOD 1
setting
Confirm
SCHEDULE
(SCH)
Select
OFF or ON
value
Go to
PERIOD 3
setting
Confirm
OFF or ON
value
Select
OFF or ON
value
Save all
OFF/ON
values
Go to
Home
Screen
Select
OFF or ON
value
Go to
PERIOD 2
setting
Confirm
OFF or ON
value
Select
OFF or ON
value
Go to
PERIOD 4
setting
Confirm
OFF or ON
value
Tabla de contenidos
Otros manuales de Admirador de SmartVent

SmartVent
SmartVent Positive2 Manual de usuario

SmartVent
SmartVent Positive2 Manual de usuario

SmartVent
SmartVent Synergy2 SYN190E2 Manual de usuario

SmartVent
SmartVent SYN1015AD Manual de usuario

SmartVent
SmartVent positive+ Manual de usuario

SmartVent
SmartVent synergy3 SYN1015AD Manual de usuario

SmartVent
SmartVent POSITIVE Series Manual de usuario

SmartVent
SmartVent SV02AD Manual de usuario